Showing results: 301 - 315 of 867 items found.
-
DX-2012SA -
Dexing Magnet Tech. Co., Ltd
Under continuous frequency of 1 kHz to 500 kHz, automatic measurement of magnetic hysteresis loop of the soft magnetic materials such as silicon steel, precision alloy, non-crystal and ferrite, accurate measurement on the dynamic magnetic characteristic parameters such as amplitude permeability µa, loss angle d, loss iron Pc, remanence Br and coercivity Hc.
-
425 -
Cooper-Atkins Corporation
Gun-Style Infrared thermometer with Dual Laser Sighting, LED Flashlight and Hi/Lo Alarm. With HDPE carrying case and magnetic stand.
-
TDK RF Solutions Inc.
TDK E-Field Generators - generate controlled, high-intensity electric and magnetic fields over the frequency range of 10kHz to 100 MHz
-
Denshijiki Industry Co., Ltd.
And the eddy current generated on the specimen by the specimen by the action of the magnetic field can not be detected (defect) and the change due to the influence of the material is detected.
-
MultiDimension Technology Co.,Ltd.
A three-axis digital magnetometer that is intended for the measurement of magnetic fields near the probe tip at frequencies less than 250 Hz.
-
SICK Sensor Intelligence
Reliable, high-performance, rugged - magnetic cylinder sensors from SICK for the T-slotMagnetic cylinder sensors from SICK ofter the perfect option for all conventional pneumatic actuators with T-slots. They are precisely tailored for the different nut tolerances. Thanks to the huge range of magnetic cylinder sensors to choose from, we can meet your every need. Drop-in mounting, short, compact design with enormous retaining force, combination bolt, safe switching point detection, sensors with two switching points, and universal mounting options using an adapter make it clear: Magnetic cylinder sensors from SICK are prepared for all installation sites and situations.
-
421 -
Oersted Technology
The Model 421 is a benchtop, laboratory gaussmeter, capable of measuring magnetic fields from 0.001 Gauss to 300 kGauss (measurement range is dependent on probe used). This unit is well-suited to magnet testing, quality assurance, and other applications requiring highly repeatable magnetic measurements. Measurements of AC and DC magnetic fields are shown in Gauss or Tesla on the two-line vacuum fluorescent display. A Sort function allows magnet parts to be quickly checked on a pass/fail basis, while the serial port enables the gaussmeter to be controlled by a computer or automation equipment. A hall-effect gaussmeter probe is included with the Model 421, and may be selected from an extensive line of probe constructions.
-
Shimadzu Corp.
The analysis of dioxins in foods was mainly performed using magnetic sector (double-focusing) GC-MS instruments. However, in June 2014, the GC-MS/MS method was officially recognized in the EU as being equivalent to the magnetic sector GC-MS method (EU 589/2014). This product consists of method files for the analysis of dioxins in foods, and a report creation tool, supporting the analysis of dioxins via GC-MS/MS.
-
4029 -
SPECTEC Innovative Sensor Solutions
SPECTEC's Model 4029 digital opto-isolated current loop signal conditioner prevents ground loops and interrupts any galvanic signals riding on magnetic speed sensor's output signal.. This signal conditioner converts magnetic, variable reluctance and inductive sensors' sinusoidal signals into a 4-20 mA output suitable for interfacing with process control units, dataloggers, flow controllers, and computers.
-
IDR-210 -
Integrity Design and Reseach Corp.
Typical Applications include checking the frequencies and magnetic fields (BW: 20-4000 Hz) produced by equipments such as computer monitors, television sets, power lines, induction heaters, industrial, scientific and medical equipment and household appliances, etc. Magnetic fields are invisible radiations, the best method to detect them is by using one of the accurate gaussmeter from Integrity Design & Research Corp.
-
2100 -
Magnetic Instrumentation Inc.
Magnetic Instrumentation manufactures Hall Effect Probes in a wide range of styles and sizes. Probes are supplied with magnetic, electrical, temperature stability and calibration data for each measurement range. Probe are supplied with flash memory and a temperature sensor that allow the 2100 Gaussmeter to correct for Hall Element inaccuracies due to temperature change. Probes are supplied with a NIST traceable Certificate of Calibration and test data.
-
TM530 -
T&M Tools Limited Co
TM530 Audio Frequency Generator is provided with Pinpoint Fault Locator for pinpointing the low resistance fault and detecting cable route. When detecting, TM530 will inject a signal current of 1kHz audio frequency into the cable, and accordingly a magnetic wave of the corresponding frequency will be generated on the cable. Pinpoint Fault Locator will collect this magnetic signal, thus obtains the information of the cable fault and the route.
-
RX-21b -
Reply S.p.A.
The RX-21 Teslameter is a portable, hall-effect magnetic field meter that measures both the DC component and the AC component of the field. The latter quantity is measured in the frequency range 20 Hz - 25 kHz as the effective value of the magnetic field (so-called true RMS), regardless of changes in the field as a function of time. The meter's operating range is 0 - 3000 mT , switched manually or automatically.
-
RX-21b -
Resonance Technology
The RX-21 Teslameter is a portable, hall-effect magnetic field meter that measures both the DC component and the AC component of the field. The latter quantity is measured in the frequency range 20 Hz - 25 kHz as the effective value of the magnetic field (so-called true RMS), regardless of changes in the field as a function of time. The meter's operating range is 0 - 3000 mT , switched manually or automatically.
-
RWA 4000 TDMR -
Guzik Technical Enterprises
Works with GSA 6044 digital signal analyzer to perform Two Dimensional Magnetic Recording (TDMR) measurements. RWA 4008 TDMR Read-Write Analyzer is a part of the new generation all-digital Guzik 4000 Series test systems. RWA 4008 TDMR requires Guzik signal analyzer GSA 6044 to provide a complete RWA TDMR solution for magnetic recording test applications.