Showing results: 1171 - 1185 of 2807 items found.
-
N7040A -
Keysight Technologies
The Keysight N7040A Rogowski coil current probe is designed for measuring AC currents up to 3,000 A with the bandwidth ranging from 3 Hz to 23 MHz. The probe is easy to use because it has a thin, lightweight, flexible and simple-to-use clip-around Rogowski coil that enables current measurement in the most difficult to reach parts and confined spaces of a circuit under test. It can also measure large AC current without increase in transducer size.
-
Rocky Mountain Laboratories, Inc.
Scanning probe microscopy (SPM) refers to a family of measurement techniques that utilize a scanning probe. The most common measurement is Atomic Force Microscopy (AFM Analysis), which measures surface topography. Imaged areas can be from the nm scale to as large as 100 µm X 100 µm. Heights and depths of features can be measuredand many surface roughness parameters, e.g Ra, can be calculated. 3-D images can also be produced for dramatic data presentation. Magnetic and electrical response can also be measured with SPM.
-
Aaronia AG
EMF & RF close field sniffer-set for use with any Spectrum Analyzer or Measurement Receiver. The EMC Near Field probe set allows for straightforward pinpointing and measurement of interference sources in electronic component groups as well as execution and monitoring of generic EMC measurement. Our RF near field probe set is especially suitable for: - Pinpointing interference sources - Estimation of interference field strength - Verification of shielding and filtering measures - Identifying faulty components - Detecting circuitry overly sensitive to interference.
-
Labfacility Ltd.
Mineral Insulated Resistance Thermometers are for use up to 500°C depending on the configuration. They are rugged, steel sheathed probes with flexible sheaths allowing bending or forming. They offer long life (depending on use) are resistant to vibration
-
Extech EX010 -
Extech Instruments Corporation
The Extech EX010 is an ExStik 3 foot Extension Cable with a Probe Guard and Weight. This product is for use with Extech meters like the DO600 Waterproof ExStik II Dissolved Oxygen Meter. The EX010 comes with a 6 month warranty.
-
Extech 850186 -
Extech Instruments Corporation
The Extech 850186 is a Surface Temperature RTD Probe. It has a platinum RTD temperature sensor (100 Ohm) capable of measuring temperature from -40°C to 250°C (-40°F to 482°F).For use with the Extech model 407907. Comes with a 6 month warranty.
-
DRM 504/4 -
GMC-I-PROSyS
The new DRM 504/4 is a 4 Phase MICRO~flex AC current Probe utilising the Rogowski principle, with 4 channel integrator housed in DIN Rail Mounted Enclosure. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and with large conductors.
-
CT4432 -
Cal Test Electronics
Because an oscilloscope has limits to the input voltage itcan accept, measuring higher voltages may sometimes require the use of anattenuating high-voltage probe. The CT4432, with an improved dual-resistor design, can accurately and safely step-downhigher voltages to an acceptable level. It offers 1000x attenuation and features a compensation range of 5 pF to 50 pF for a wide range ofoscilloscope capacitance matching.
-
U1818B -
Keysight Technologies
The Keysight U1818B 100 kHz to 12 GHz active differential probe makes it easy to perform high frequency in-circuit measurements using network, spectrum and signal source analyzers. With flat frequency response, low noise floor, and direct power from instrument connection, the U1818B allows measurements to be made while taking full advantage of Keysight's RF analyzers dynamic range.
-
U1818A -
Keysight Technologies
The Keysight U1818A 100 kHz to 7 GHz active differential probe makes it easy to perform high frequency in-circuit measurements using network, spectrum and signal source analyzers. With flat frequency response, low noise floor, and direct power from instrument connection, the U1818A allows measurements to be made while taking full advantage of Keysight's RF analyzers dynamic range.
-
I-prober 520 -
Aim-TTi
Current measurement from insulated probing of conductorSuitable for observation and measurement of current in PCB tracks, component leads and ground planesWide dynamic range of 10mA to 20A peak to peakWide bandwidth of DC to 5MHzLow noise figure equivalent to <6mA rms at full B/WSafety rated to 300V Cat II (600V Cat 1)Suitable for connection to any oscilloscopeHigh accuracy general purpose H-field probeConverts to 'closed magnetic circuit' current probe
-
MetrologyWorks, Inc.
Single Piece Aluminum InsertWe have assembled this SMR in a way that the insert will not come out. When you drop the competitions SMR they shift or pop out after a few short drops. With our Rhino Series SMR, Drop, Pickup, and Measure on. You get the performance of a solid SMR that is much more affordable. These are available in High Accuracy SMR versions. We keep the Rhino Series SMR s in stock at all times.
-
CyberScan pH 11 -
Thermo Scientific
5-point Push-Button Calibration with Auto-Buffer Recognition for quick calibration with no calibration mistakes
-
FLIR TA74 -
Teledyne FLIR
The FLIR TA74 adds capabilities, simplifies challenges, and gives you the best readings with your existing meter. The narrow, 18-inch long flexible coil clamp and locking mechanism allows you take measurements in tight or awkward spots – ideal for multiple conductor measurements, double-wrap requirements, and deeper access. The connection is a standard banana plug and the output is a voltage signal, so it’s compatible with most DMMs and clamp meters, regardless of brand.
-
1668A -
Peaceful Thriving Enterprise Co Ltd
Check on 6 and 12V systems. To indicate whether there is an electrical potential at any low voltage point in the system. By using the pointed contact tip to pierce insulation on cables, it will also indicate if current is present. This can be helpful when tracing faults or add cable to a circuit.