Showing results: 1036 - 1050 of 2807 items found.
-
8696 -
TEGAM Inc.
Model 8696, platinum RTD probe is designed for measuring air and other gaseous mediums. The sheath is 8" long and is constructed with #304 stainless steel. The probe tip is protected from temperature fluctuations by a perforated shield. The probe''s 4-inch handle is connected to a thermoplastic coil cord that extends from 1-1/2 feet to 5 feet.
-
-
-
PK-HV-001 -
Teledyne LeCroy
Accessory kit for High Voltage Differential Probe
-
PACC-MS003 -
Teledyne LeCroy
High Frequency Cartridge for HFP Series Probes
-
-
HVP120 -
Teledyne LeCroy
High voltage single-ended passive probes are suitable for a wide range of applications where ground-referenced high-voltage measurements must be made safely and accurately. There is also a sense pin to automatically configure the oscilloscope for use with the probe.
-
Nav-Aids Ltd
This Pitot Probe Cover developed by Nav-Aids Ltd. withstands temperature to 950 degrees F when installed on the pitot tube.With the Nav-Aids Ltd. High Temperature Pitot Probe Cover installed on the pitot tube, and the heat inadvertently activated, there will be : No melting of material No significant residue on the pitot tube No filling of static or drain holes No need to change a pitot probe No cause for aircraft dispatch delay
-
Equip-Test Kft.
Equip-Test Threaded Probes Designed for Connector and Harness Test
-
Extech TP882 -
Extech Instruments Corporation
Extech's TP882 is a penetration temperature probe. This Type-K probe measures from -46°C to 538°C (-50°F to 1000°F) with a subminiature (mini-ANSI) connector. Compatible with most meters that have Type-K temperature function.
-
CP031A -
Teledyne LeCroy
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
CP030A -
Teledyne LeCroy
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
Extech TP873-5M -
Extech Instruments Corporation
The Extech TP873-5M is a Type-K temperature probe with a mini-connector and banana plug adaptor. The extra-long bead wire extends 5 meters (16 ft), while the probe itself can measure temperatures from -30°C to 300°C (-22°F to 572°F).
-
SX set -
Langer EMV-Technik GmbH
The SX1 set consists of 3 passive near field probes for making measurements in the development phase of E-field and magnetic field with a high clock frequency in the range from 1 GHz to 10 GHz. The probe heads of the set SX allow for measurements close to electronic assemblies, e.g. on single IC pins, conducting paths, components and their connectors, to localize interference sources. Field orientation and field distribution on an electronic assembly can be detected through trained use of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They have an internal terminating resistance.
-
85024A -
Keysight Technologies
85024A high-frequency probe makes it easy to perform in-circuit measurements. An input capacitance of only 0.7 pF shunted by 1 megohm of resistance permits high frequency probing without adversely loading the circuit under test. Excellent frequency response and unity gain guarantee high accuracy in swept measurements with this probe. High probe sensitivity and low distortion levels allow measurements to be made while taking advantage of the full dynamic range of RF analyzers.