  • Digital Earth Resistance Tester

    8PK-ST1520 - Prokit's Industries Co., Ltd.

    Capable of measuring earth voltage (Vac.) 2mA measuring current permits earth resistance to test without tripping earth leakage current breakers in the circuit. Battery operated. Auto power off function. Data hold function. Small and light weight.

  • Peel Resistance of Adhesive Bonds

    ASTM D1781 - National Technical Systems

    This test method is used to compare adhesion between flexible and rigid adherents, or between flexible facing of a sandwich structure and its core. Comparisons of adhesives and processes are only applicable when test specimens and conditions are the same. The peel resistance may indicate degree of cure for relatively brittle adhesives.

  • Transformer Winding Resistance Meters

    RMO TW Series - Amperis sl

    The RMO-TW instrument can perform a simple, fast and reliable verification of a transformer on-load tap changer. This instrument allows measurements of a winding resistance at each tapping position of an on-load tap changer without discharging between tests. Problems with OLTC switching, such as interruption, can be detected with these measurements. The results are displayed on a backlit LCD screen.

  • Digital Earth Resistance Testers

    ST-1520 - MRC ltd.

    Capable of measuring earth voltage.2mA measuring current permits the testing of earth resistance without tripping earth leakage current circuit breakers in the circuit.Auto power off function.The timer operates automatically for approximately three to five minutes when the "push button switch" and "timer on button" are pressed together.

  • Contact Resistance Measurement System

    CRMS - Ultra-Tech Enterprises, Inc.,

    The CRMS is a system designed to allow any user to measure the resistance of each set of relay contacts associated with the relay under test. The test system consists of a CONTACT RESISTANCE MEASUREMENT UNIT (CRMU), a MULTIPLE RELAY TEST RACK, as well as an interconnect CABLE ASSEMBLY. Either DC or AC energy to pick and drop relay coils under test for all contact measurements is supplied from the CRMU and easily interfaces with the Multiple Relay Test Rack. For additional and more thorough testing of relays an external relay tester can be interfaced to the Multiple Relay Test Rack to supply energy to the relay coil. It is recommended that the UTE Relay Tester With Timer/Counter (UTE Product # 15967-00) be utilized so the operator can take full advantage of the unique features it offers

  • Electrical Resistance (ER) Monitoring

    Metal Samples Company

    The electrical resistance (ER) technique is an "on-line" method of monitoring the rate of corrosion and the extent of total metal loss for any metallic equipment or structure. The ER technique measures the effects of both the electrochemical and the mechanical components of corrosion such as erosion or cavitation. It is the only on-line, instrumented technique applicable to virtually all types of corrosive environments.

  • Linear Polarization Resistance Probes

    Metal Samples Company

    Linear polarization resistance (rosion probes are commonly used in the water treating industry and other environments where instantaneous, on-line corrosion rate readings are required. Linear polarization probes are ideally suited to monitor fluctuations that may occur within a system; for example, these probes can be used to monitor corrosion inhibitor effects on a regular basis.

  • Insulation Resistance Measuring Equipment

    AMIC-5010 - Amperis sl

    Insulation resistance measurement - 15TΩ: * 50 - 1000 V, in 10 V steps, * 1000 - 5000 V, in 25 V steps ; Memory of 999 results and transmission to PC ; Measurement of AC and DC voltage and capacity ; Measurement of leakage current and function with digital filter ; Measurement of continuity of protection and equipotential connections ; Adjustable alarm limits

  • Analog Surface Resistance Meter

    Desco Industries, Inc.

    Analog Compliance Verification Surface Resistance CheckerUse to test worksurfaces, shelving, carts, garments, chairs to ANSI/ESD S20.20 per ESD TR53Automatic Test Range Voltage Selection Per Compliance Verification ESD TR53Starts tests at 10 volts and automatically switches to 100 volts if the measurement is over 105 ohmsPortable Operation with 9 Volt Battery

  • Transformer Winding Resistance Meters

    RMO TT Series - Amperis sl

    The Tap Changer Analyzer & Winding Ohmmeter of the RMO-TT series is designed for winding resistance measurement of inductive objects, and for a tap changer analysis. The RMO-TT series is based on the state of the art technology, using the most advanced switch mode technology available today. The RMO-TT instruments are accurate (0,1%), powerful (up to 100 A) and still portable. The Instruments generate a true DC ripple free current with automatically regulated measurement and discharging circuit. RMO-TT instruments can perform a simple, quick and reliable transformer on-load tap changer condition assessment. This series of instruments enable measurements of a winding resistance in every tap position, current ripple values (percentage of a current drop during a tap change) and transition times during the tap changes. Problems with a connection, contacts, and selector/diverter switch operation (tap change with interruption) can be detected with these measurements.

  • Micro-Ohmmeter and Loop Resistance Tester

    LRT 6000 - ATEQ Aviation

    LRT 6000: The right solution for impedance resistance measurement in compliance with all aircraft specifications on plane, helicopter, rocket, army vehicles for both production andmaintenance. It is a very easy-to-use and versatile instrument. Its ergonomics allow the user to use it either placed on the ground or across one's shoulder or chest. Awide back-lit LCDdisplay combinedwith an intuitive keyboard ensures simple and easy operation.

  • Resistance Grounded Systems (HRG/LRG)

    Bender Inc.

    Neutral Grounding Resistors (NGRs) are used to limit the maximum ground-fault current. Restriction of fault current lowers hazards and reduces damage done to equipment. High Resistance Grounding (HRG) systems are often used on industrial and critical power applications to maintain system uptime during a first ground fault. HRG systems are also used in tripping applications to help control touch potential on portable loads and improve personnel safety.

  • Moisture Resistance/ Humidity Test

    Aero Nav Laboratories, Inc.

    This test is performed for evaluating the resistance of component parts and constituent materials to the deteriorative effects of the high-humidity and heat conditions typical of tropical environments. Most tropical degradation results directly or indirectly from absorption of moisture vapor, and from surface wetting. These phenomena produce many types of deterioration, including corrosion of metals; physical distortion and decomposition of organic materials; leaching out of constituent components of materials, and detrimental changes in electrical properties.

  • Ground Earth Resistance Tester

    2678X - Shenzhen Chuangxin Instruments Co., Ltd.

    Ground Earth Resistance Tester verifies the integrity (continuity) of the protective bonding of the equipment (Class I equipment) designed to secure safety through the basic insulation and protective earthing. It is also called earth (ground) bonding test. If the continuity of the protective bonding is confirmed, we can conclude that the equipment has the requirements for preventing electric shock even if the insulation between the primary circuit and the accessible conductive section fails and a fault current flows through the distribution system.

  • Generator Insulation Resistance Tester

    WA2660 - Wuhan Sangao Electrical Test Installations Limit Co.

    WA2660 series insulation resistance testing instrument is special use for internal water cooling generator's measurement test. Meanwhile, can also be used in laboratory or field insulation test.The output current is greater than 25mA,Maximum output voltage is 2500V.With high precision micro current measurement system, digital boost system.Only need a high-voltage line and a signal line connecting the sample can be measured.Automatic measurement, the results from the large screen liquid crystal display, and the results are stored.