Filter Results By:

Products

Applications

Manufacturers

Resistance

that which keeps current from flowing freely.

See Also: Resistivity, Resistance Standards, Resistance Meters, Resistance Test, 4-wire


Showing results: 2431 - 2445 of 2647 items found.

  • LXI Low Thermal EMF Matrix 1-pole 28x33

    60-510-003 - Pickering Interfaces Ltd.

    The 60-510 is a high density 1-pole matrix module controlled via LXI. It has excellent thermal stability and substantially reduced thermal EMF figures when compared to a conventional switching matrix. Typical applications include signal routing in ATE, selecting thermocouple inputs, switching amplifier gain circuits and high accuracy DC micro-volt measurements. Ruthenium reed switches are used because of their good low level switching capability. They also have a very long life with excellent contact resistance stability, minimal wetting current and low thermal offset.

  • Linear Gauge Sensors

    GS Series - Ono Sokki

    All the GS series Digital Linear Gauges are upgraded. The GS-1700/1800 series is a compact and cost effective basic type. The GS-6700/6800 series is a vibration resistant type which provides better performance of vibration resistance 1.5 times in strength compared to the basic type. The GS-4700/4800 pursuits heavy-duty performance required in production site. Long stroke type the GS-5050/5100 series has wide measurement range (stroke) at 50 mm or 100 mm. Using ball bearing mechanisms in these all models greatly increases bearing life.

  • On-Board Systems

    OBS-ONE series - HORIBA, Ltd.

    HORIBA developed the OBS-ONE series on-board emission measurement system in response to new requirements for exhaust emissions measurement from vehicles being driven on public roads (Portable Emissions Measurement Systems - PEMS). This development has been made possible by reducing the dimensions and power consumption of laboratory grade analyzers and ensuring that the system components have excellent vibration resistance. The OBS-ONE series continuously measures not only the concentration of CO, CO2, THC and NOx, but also measures exhaust fl ow rate and A/F ratio to calculate mass emission and fuel economy.

  • PXI RTD Simulator Module 12-Channel PT1000

    40-262-202 - Pickering Interfaces Ltd.

    The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.

  • PXI RTD Simulator Module 18-Channel PT1000

    40-262-002 - Pickering Interfaces Ltd.

    The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.

  • PXI RTD Simulator Module 6-Channel PT100

    40-262-101 - Pickering Interfaces Ltd.

    The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.

  • Milliohm Meters

    Chroma 16502 - Chroma Systems Solutions, Inc.

    With a basic accuracy of 0.05%, Chroma 16502 offers a 0.001mΩ ~1.9999MΩ wide measurement range. It provides measurement range with 4 1/2 digits resolution. The fast measurement time is 65 ms. It suits component evaluation on production line. Pulsed test current output mode is used to reduce thermal EMFs affection on milliohm measurement. DC test current output mode is used to fasten measurement speed for inductive DUT. Dry-circuit test current output mode is used to measure such contact resistances where the maximum open-circuit voltage must be limited to 20mV.

  • Chroma LCR Meters

    Chroma Systems Solutions, Inc.

    Some of the key features to look for in an LCR meter (also known as an impedance meter) are: accuracy, test frequency, measured parameters, test voltage and test current. Additionally, an easy to understand display of test results and the ability to access and use these results has become increasingly important. Component testing often requires much more than simply a resistance, capacitance or inductance value at a given test frequency and stimulus voltage. An LCR meter or impedance meter must have the flexibility to provide multi-parameters over wide frequency and voltage ranges.

  • Flash SATA CFast™ SLC ,MLC

    FSC Series - Axiomtek Co., Ltd.

    *Compliant with CFast™ 2.0 Standard, Capacity SLC: 2 GB ~ 64 GB, MLC: 4 GB ~ 128 GB*SATAIII interface*Suitable for high demanding applications*Well performed under harsh operating environment and industrial temperatures*Anti-vibration & shock resistance*Support static wear leveling algorithm*S.M.A.R.T. & i-S.M.A.R.T. Supported*Intelligent system for error recovery*Excellent data transfer speed*Extremely low power consumption*High operating reliability & durability*Hardware write protect*Enhanced power cycling management

  • Glow Wire Test Apparatus

    SCR ELEKTRONIKS

    GLOW WIRE TESTER (also known as Glow Wire Test Apparatus) is designed to carry out fire hazard testing as specified in IEC 60695-2-10 2000-10. Flammability test is to check the ‘Resistance to Fire’ of electrical insulators that touch directly conducting parts & also parts of insulators. This test is also referred in many other standards such as IS 11000, IS 3854 : 1997 / IS 1293 :1988 / IS 371 :1999 & IS 11000 Pt 2 Sec 1, IEC 60335, IEC 884/94, IEC 60598, IEC 61058, BS 6458, BS EN 60695–2-10,11,12, etc.

  • Glow Wire Test Apparatus

    GWT A2 - SCR ELEKTRONIKS

    GLOW WIRE TESTER (also known as Glow Wire Test Apparatus) is designed to carry out fire hazard testing as specified in IEC 60695-2-10 2000-10. Flammability test is to check the ‘Resistance to Fire’ of electrical insulators that touch directly conducting parts & also parts of insulators. This test is also referred in many other standards such as IS 11000, IS 3854 : 1997 / IS 1293 :1988 / IS 371 :1999 & IS 11000 Pt 2 Sec 1, IEC 60335, IEC 884/94, IEC 60598, IEC 61058, BS 6458, BS EN 60695–2-10,11,12, etc.

  • Ohm-Stat Digital Display Megohmmeter

    Static Solutions Inc.

    Measures resistivity RTT, RTV, and RTG 103-1012 ohms/sq., ohms, ohm-cmRelative humidity 10% 90% RHTemperature 32oF 100oFDigital display: easy to interpretNIST calibration includedIncludes chair probe to measure smocks, earth ground, chairs, and resistance probes: $400 value for freeResistivity probe built in the bottom of meterProduct conforms to the ESD S.20.20 spec standardsCE mark includedThe kit includes, two (5) lb probes, coil cords, hard carrying case, battery, 110v or 220v adaptor, garment clips, chair probe, and ground circuit tester

  • Ozone Climatic Test Chamber

    ACMAS Technologies Pvt. Ltd.

    The Ozone Test Chamber provide an effective solution to the testing of products for resistance against ozone degradation in a controlled environment. These test chambers function as static tensile test chambers as well as Rubber Test Chamber and are often used for studying static tensile deformation of various manufactured goods in the presence of ozone. The equipment works by exposing the test samples to uniform concentrations of ozone at constant temperatures and relative humidity in a sealed air environment. Under these conditions, the products undergo the process of corrosion which can be observed in the form of surface cracks and changes in other properties.

  • Reach-In Xenon Lamp Weathering Test Chamber

    ACMAS Technologies Pvt. Ltd.

    Weiber xenon lamp chamber uses xenon lamp to simulate the whole sunlight spectrum that can produce many destructive effects on the products. This simulation environment provided in the chamber is used to test the resistance of various manufactured products towards these destructive conditions. This chamber is used for quality control, product development and scientific researches and many more. With a variety of models and options, you can customize your chamber to fit your testing needs. Reach in chambers provide a compact testing area for small applications. These are easy to install, transport and occupies less space.

  • AC Ground Bond Tester

    446 - SCI

    Our 446 model is a 4-in-1 tester with AC Hipot, DC Hipot, Insulation Resistance, and Ground Bond capabilities. This tester features a simple design and easy-to-use interface, reducing setup time and increasing production-line throughput for your application. The 446 is equipped with multiple memories and an optional USB port for remote BUS communication so you can quickly perform tests on a variety of DUTs from the front panel or with a PC. Add to user safety by equipping your tester with Personal Protective Equipment (PPE) via the built-in safety interlock.

Get Help