Filter Results By:

Products

Applications

Manufacturers

Resistance

that which keeps current from flowing freely.

See Also: Resistivity, Resistance Standards, Resistance Meters, Resistance Test, 4-wire


Showing results: 1786 - 1800 of 2670 items found.

  • Passive Probe, 500 MHz, 10:1, 1 MOhm/10 MOhm

    PP020-1 - Teledyne LeCroy

    Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.

  • 500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm

    PP023-1 - Teledyne LeCroy

    Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.

  • 500 MHz Passive Probe, 5mm, 10:1, 10 MOhm

    PP024-1 - Teledyne LeCroy

    Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.

  • 500 MHz Passive Probe, 5mm, 10:1, 10 MOhm

    PP025-1 - Teledyne LeCroy

    Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.

  • 500 MHz Passive Probe, 5mm, 10:1, 10 MOhm

    PP026-1 - Teledyne LeCroy

    Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.

  • Underground Cable Fault Locator

    KM-CFPL-620 /620B - Kusam Electrical Industries Limited

    “KUSAM-MECO” underground Cable Fault Pre-locator is an automatic Cable Fault Locator which adopts ARM, FPGA & Dot Matrix Color LCD display Technology. This tester combines both pulse reflecting technology (TDR) & (intelligent Bridge testing (Bridge) (Model-KM-CFPL-620B) for measuring the exact fault location such as broken line, cross faults, earthing, (poor insulation & poor contact of the lead covered cables as well as plastic cables. (Model-KM-CFPL-620B)).It is a microprocessor based fault locator with a user friendly menu. It is easy to operate. It tests almost all telecom & signal cables. It has an English menu which is easy to understand & use. With Megameter & Ohmmeter it enables to test insulation resistance & loop resistance. It has USB Port for uploading test data to computer

  • 2 in 1 LAN Tester

    PLTM20 - Pyle Audio Inc.

    Tests Pin Configuration for 10 Base-T, 10 Base-2, RJ45/RJ11, 356A, TIA-569A/568B and Token Ring CableRemotely Test Cables Up to 330 Yards AwayTest Ground WireMeasure DC/AC Voltage, DC/AC Current, Resistance, Continuity, and DiodeDC Voltage: Max Range 600 V, Accuracy +/- 0.5%AC Voltage: Max Range 600 V, Accuracy +/- 1.2%DC Current: Max Range 200 mA, Accuracy +/- 1.2%AC Current: Max Range 200 mA, Accuracy +/- 2.0%Resistance: Max Range 20 M, Accuracy +/- 0.8%Continuity Test: Beeps If Less Than 100 Accessories Included: Test Leads, LANtest Remote Terminator, 9V Battery, Carrying CaseDimensions: 6.38' H x 2.93' W x 1.73' DWeight: 10.86 oz.Sold as : Unit

  • Digital Insulation Multimeter Tester 1 KV

    MIRT-61 - The Motwane Manufacturing Company

    The MOTWANE multipurpose tester Model MIRT-61 is a Versatile, battery operated Digital insulation tester with true RMS industrial grade multimeter features best suited for industrial preventive maintenance. With test voltage range up to 1 KV , highest insulation resistance range of 6G Ohm and multi featured function of RMS multimeter (i.e. AC/DC 1000 V) ; makes it a superior offering for Industry and Service segment. It is designed predominantly for low voltage insulation resistance testing in maintenance and services, which involves the applications like Cables/Wires, Rotating Machines, LT transformers, Switchgears and Industrial installations. It is designed to suit the extreme environment conditions. Save your operating cost and test more with this single box design rather buying two different products.

  • Load Cell Simulator

    SY040 - Synectic Electronics

    SY040 Load Cell Simulator High Precision Instrumentation generates a mV/V signal.  A great high precision simulator to use for either test, calibrating and also troubleshoot strain gauge applications.  A wide range of bridge resistances can also be simulated including 350, 700, 1000, 1400 & 2000 ohm.  The range of preset switch positions include 0, 0.2, 0.4, 0.6, 0.8, 1.0, 2.0, 3.0, 3.5, 4.0 & 4.5 mV/V.  The option of very fine adjustments is also possible as this instrument has a knob for continuously variable adjustments between the preset ranges.  Users can make a connection via 4mm banana connectors mounted on top of the case.

  • Temperature & Process Calibrators

    GAO Tek Inc.

    The most sophisticated industrial equipment will not be useful unless it is calibrated. GAOTek Process Calibrators are used to adjust instruments’ accuracy, and they are the only process calibrator you will ever need to carry. They can measure temperature, pressure, voltage, resistance and frequency, and can be used during troubleshooting. Through calibration, you can ensure that any equipment performs as expected and that it can be relied on to deliver predictable and accurate results that meet quality standards. GAOTek Process Calibrators come with a USB interface which makes it easier to transfer the results to other devices which otherwise would have taken a long time to transcribe them. Our Process Calibrators are for sale to the United States, Canada and globally.

  • High Precision Pointer Multimeter

    KT3202 - Ketai instrument (kunshan) Ltd.

    It has AC and DC voltage, DC current, resistance, capacitance, continuity, and diode measurement functions.Comply with safety standard CAT III 600V Fuse Φ6x31mm 600VKT3202 is a specially designed AC and DC voltmeter.KT32034 specially designed AC and DC ammeter.KT3204 is a specially designed DC low-current, low-voltage meter. The voltage can be measured from 0 to 100mV, and the current can be measured from 0 to 50uA.The pointer "0" is at the median value, and the voltage and current are divided into two sides.This set of four tables has certain practical significance for students' knowledge and understanding of Ohm's law in electrical engineering.This set of meters complies with the CAT III 600V standard.

  • High Precision Pointer Multimeter

    KT3204 - Ketai instrument (kunshan) Ltd.

    It has AC and DC voltage, DC current, resistance, capacitance, continuity, and diode measurement functions.Comply with safety standard CAT III 600V Fuse Φ6x31mm 600VKT3202 is a specially designed AC and DC voltmeter.KT32034 specially designed AC and DC ammeter.KT3204 is a specially designed DC low-current, low-voltage meter. The voltage can be measured from 0 to 100mV, and the current can be measured from 0 to 50uA.The pointer "0" is at the median value, and the voltage and current are divided into two sides.This set of four tables has certain practical significance for students' knowledge and understanding of Ohm's law in electrical engineering.This set of meters complies with the CAT III 600V standard.

  • Tantalum-Polymer

    POSCAP™ - Panasonic Industrial Devices Sales Company of America

    Panasonic POSCAP™ Solid Electrolyte Chip Capacitors offer stable capacitance at high frequency and temperature, with low-ESR/ESL. These Capacitors utilize a sintered tantalum anode with a proprietary high-conductivity polymer cathode. Panasonic's innovative construction and processing yields one of the lowest ESR levels in Tantalum-Polymer Capacitor technology, while exhibiting excellent performance in high frequency applications. POSCAP Capacitors are available in various, compact package sizes for a small PCB footprint while offering high volumetric efficiency for capacitance. In addition, Panasonic’s POSCAP parts demonstrate high reliability and high heat resistance, making them the ideal Chip Capacitor for digital, high-frequency devices and more.

  • Planar-Doped Barrier Diode Detector, 0.01 to 50 GHz

    8474E - Keysight Technologies

    The Keysight 8474E is a high-performance detector using a gallium arsenide, planar-doped barrier detecting element. It features extremely flat frequency response over its entire band of operation and very good frequency response stability versus temperature. The Keysight 8474E is also very rugged with high resistance to ESD damage. The Keysight 8474E detector is available with a 2.4-mm (0.01 to 50 GHz) connector. This detector offers the options for optimal square-law loads (Option 102) and for positive polarity output (Option 103). Because the unit-to-unit frequency response tracking of this device is typically better than plus or minus 0.3 dB, no matched response option is offered.

  • Planar-Doped Barrier Diode Detector, 0.01 to 18 GHz

    8474B - Keysight Technologies

    The Keysight 8474B is a high-performance detector using a gallium arsenide, planar-doped barrier detecting element. It features extremely flat frequency response over its entire band of operation and very good frequency response stability versus temperature. The Keysight 8474B is also very rugged with high resistance to ESD damage. The Keysight 8474B detectors are available with 0.01 to 18 GHz and a type-N connector. This detector offers options for optimal square-law loads (Option 102) and for positive polarity output (Option 103). Because the unit-to-unit frequency response tracking of these devices is typically better than plus or minus 0.3 dB, no matched response option is offered.

Get Help