  • PXIe-5650, 1.3 GHz RF Signal Generator

    781215-01 - NI

    The PXIe‑5650 features continuous-wave generation capabilities with FM, 2‑FSK, or OOK modulation. It uses direct digital synthesis (DDS) for high-resolution frequency hopping or phase-continuous sweeping for fixture and device characterization applications. The PXIe‑5650 is ideal for clocking nonstandard sample rates, such as WCDMA signals at baseband or intermediate frequency (IF). With these versatile signal generators, you can perform analog and digital modulation through the onboard DDS circuit, which gives you frequency modulation and frequency-shift keying for applications such as bit error rate test, antenna testing, or even keyless entry. You can also perform amplitude modulation using on-off keying.

  • PXI-5650, 1.3 GHz RF Signal Generator

    779670-00 - NI

    The PXI‑5650 features continuous-wave generation capabilities with FM, 2‑FSK, or OOK modulation. It uses direct digital synthesis (DDS) for high-resolution frequency hopping or phase-continuous sweeping for fixture and device characterization applications. The PXI‑5650 is ideal for clocking nonstandard sample rates, such as WCDMA signals at baseband or intermediate frequency (IF). With these versatile signal generators, you can perform analog and digital modulation through the onboard DDS circuit, which gives you frequency modulation and frequency-shift keying for applications such as bit error rate test, antenna testing, or even keyless entry. You can also perform amplitude modulation using on-off keying.

  • - Optical / RF Converter

    OPT 80 - Unaohm Start S.r.l.

    Calibrated measurement of the optical power of satellite and terrestrial TV signals distributed in optical fiber Calculation of optical signal losses on distribution Measurement of digital parameters (BER - MER - NM etc.) of optical signals converted into RF Visualization of optical carriers in RF Field Metric Spectrum Analyzer Power Meter Optical Field Meter Display Optical RF Power Supply Line Link Meter (LNB power supply ) Optical LNB power supply 13V 500mA with short circuit and overload managementAcquisition of optical measurements using the field meter Data Logger Option: certification of the OPT80 calibration and optical power measurements

  • Relay Test Set

    RNT-5A - Neutronics Manufacturing Co.

    This is a portable testing kit in one unit, suitable for testing protective relay, over current relay, earth fault relay, protective device, circuit breaker, tripping coils etc.The set is designed for both laboratory and field use. TECHNICAL FEATURES: INPUT : 230 Volts, single phase, 50Hz. AC. OUTPUTS : : 1) Current Output: a) 0- 1Amp. At 6/60Volts. (Continuous duty). b) 0- 5 Amps. At 6/60 Volts. (Continuous duty). c) 0- 10 Amps. At 6/60 Volts. (Continuous duty). d) 0- 20 Amps. At 6 Volts. (for30 min. duty). e) 0- 50 Amps. At 6Volts. (For 10 min. duty). f) 0-100 Amps. At 6 volts. (For10 min. duty). g) 0-200 Amps at 6Volts. (For 30 sec. duty). Current output is continuously variable and the output is taken out through a multi range C.T. The secondary is connected to an ammeter scaled in 0 to 100%. Output current range 1Amp. To 20Amps. Are selected by current range selector switch with common output terminals and for other three ranges three brass terminals are provided of proper ratting. 2) AC Voltage Output: Continuously variable 0 -230V AC. Capacity- 240VA (Max). OR DC Voltage Output: Continuously Variable 0-240V DC. Capacity-240VA.(max). One change over switch should be provided for selection of Volt. Meter for AC or DC voltage output & either AC or Dc voltage should be available at a time. 3) Time Measurement: 0-9.999Secs. & 0-99.99Secs. in two ranges. Accuracy: 1% CURRENT CIRCUIT: Loading transformer: Double winding loading transformer of suitable burden to provided corresponding current output specified before. One change over switch in current ckt. To be provided for voltage selection i.e. selection of 10volt. Or 50volt. Measuring CT: Multi ratio wound primary current transformer Ratio : 1-5-10-20-50-100-200A/5A. Variable auto transformer: For smooth variation of current output at various ranges selected. Tripping circuit: The current output will be cutoff incase of any overload for the range 200A or even if the relay under test actuated.

  • 100 Ampere Micro OHM Meters

    Neutronics Manufacturing Co.

    Introduction: Measuring the line loop contact resistance by bridges is not the ideal method as the test current is only a few milli amperes. Thus the value is not the true value of the contact resistance. Model HL- 100 is a direct reading tester,  and uses a test current of 100A DC,  resulting in true v alue and accur ate measurements. Model HL- 100 adopts digital circuit technique and is used for measuring contact resistance of switch control equipments at test current of 100A DC. The measurements are accurate as the test is highly stable.HL- 100 is a new,  fully automatic micro controlled tester that measures contact resistance at 100A DC with built in printer. The advantages of HL-100

  • MOD MONITOR

    TYPE HFX-1 - National RF, Inc

    The Type HFX-1 Modulation Monitor is an ancillary piece of equipment, which is used with narrow bandwidth, or older oscilloscopes to allow viewing of RF signals and particularly modulated signals as high as 55MHz. The equipment contains an RF signal source and a broadband mixing circuit which converts the high frequency signal to an intermediate frequency within the oscilloscope’s range. The frequency control dial is simply adjusted until the RF signal is viewed on the scope. BNC connectors are mounted on the rear panel to allow interconnect to the scope and RF probe. This product was previously called "oscilloscope frequency extender" and may be used to view other high frequency signals on older or narrow band scopes.

  • RF Milliwatt Meters

    Type NDB-2 and NDB-3 - National RF, Inc

    National RF’s Type NDB-2 and NDB-3 RF Milliwatt Meters are affordable pieces of test equipment for both the RF laboratory and the home experimenter. Both provide a digital reading of RF power in dB reference 1 milliwatt of power into a 50 ohm load (i.e. 0 dBm). The circuitry consists of a low noise logarithmic amplifier that drives a digital A/D converting meter circuit. The lowest power levels that can be read are about –73 dBm (approximately 40 microvolts or .00000003 milliwatts). The maximum power input should not exceed 10 milliwatts (+10 dBm or .010 watts) when inputed without attenuation. An internal attenuator is provided and described in the next section.

  • 300-Watt AC/DC Power Supply, 6U VME

    Model 56SQ2 - North Atlantic Industries

    NAI’s 56SQ2 is a 300 Watt AC/DC Power Supply that uses two slots in a standard VME chassis. It is conduction-cooled through the card edge/wedgelock. This power supply accepts either a single- or three-phase input and provides up to 5 standard VME outputs plus standby at 300 Watts. It is designed for VME and general purpose applications. An onboard microcontroller allows for design flexibility.Standard features include continuous Background Built-in-Test (BIT); remote error sensing; holdup time; and protection against transients, overvoltage and short circuits. Options such as power fail warning, vibration testing, over-temperature monitoring and shutdown, current share, and extensive signaling (including ANSI/VITA) are available.

  • Design for Test Service

    Testing House, Inc.

    Design For Test (DFT) is a technique used to implement certain testability features into a product. Testing House can provide an analysis of the CAD data for testability of your circuit board. Access to a board can be very difficult as boards get smaller and designs get more densely populated. We can work with your design engineer to improve testability and maintain an effective in-circuit test. When access to the board is limited and boundary scan devices are present, we can provide the customer a list of key nodes that will require access in order to provide a very effective test. Our analysis will provide a list of all the accessible test points and an explanation for any nodes declared inaccessible.

  • Solid-State Inline (SIP) Four-Pin Relays

    Series AS4 - Teledyne Defense Electronics Relays & Coax Switch

    Series AS4 solid-state single inline (SIP) four-pin relays are designed for mounting on a printed circuit board. The relays offer built-in voltage protection and can withstand very high current overloads. The relays have a low zero-cross window. The compact size and triac output make the AS relay the perfect retrofit for electromechanical relays. All Series AS relays are Zero-Cross switching.​Available options include:AS24D4E/R 4Arms, 12-275Vrms, 600Vpeak Load; 4-30Vdc ControlAS24D4E-X1 4Arms, 12-275Vrms, 600Vpeak Load; 6-30Vdc Control; ​DIN-rail clip+LEDAS24D4E-X2 4Arms, 12-275Vrms, 600Vpeak Load; 6-30Vdc Control; ​DIN-rail clip​​AS46D4E/R 5Arms, 12-460Vrms, 800Vpeak Load; 4-30Vdc Control

  • LED Test Programmable DC Electronic Load

    IT8912E Series - I-TECH Electronic Co., Ltd

    IT8900 series high accuracy LED specific testing electronic loads can simulate the real output of LED lights with different characteristics.Their specific circuit can realize CR-LED mode, adjustable frequency, duty ratio PWM dimming output port (frequency: 20Hz-2KHz), I-pp/I-max measurement function can test current ripple and start up surge current of LED constant flow source. Voltage and current testing speed can reach 50KHz. IT8900 series provides CR-LED / CC / CV + CC / CR /CW and other working modes, built-in USB / RS232 / GPIB communication interface. Widely used in LED driver power dimming test.

  • Precision Flying Probe Platforms For Automated Test Applications

    Huntron

    Flying Probe technology is used to automate the testing of printed circuit boards (PCB) that would otherwise have to be tested manually. Adding a Huntron Access Prober to your test procedure will significantly decrease test times therefore increasing productivity.Access Probers can accurately place a probe on test points with high accuracy achieved using micro-stepping motors and linear laser encoders. Probing the smallest surface mounted devices is possible. Huntron Access Probers can automate your unique test process using the standard probe or by adding a custom probe of your design. Huntron offers three Flying Probe system configurations based on PCB size and test head requirements.

  • Crank Angle Measurement System

    CP-5110B Detector/CA-6000B Amplifier - Ono Sokki

    CP / CA series are systems that detect the rotation angle of the engine crankshaft composed of CP-5110B Fiber Optic Crank Angle Detector, CA-6000B Crank Angle Amplifier and CP-5120 / 5130 Slit disk.CP-5110B Fiber Optic Crank Angle Detector makes it possible to detect the crank angle required for various engine performance tests such as combustion analysis with high accuracy and high response. As it has a light projecting and receiving method with an optical fiber, it provides outstanding vibration and noise resistance without a built-in electric circuit in the detector.CA-6000B Crank Angle Amplifier inputs a signal of crank angle detector and outputs a TTL level angle signal and a 1P / R pulse signal.

  • MMW Field Sensors

    ITS-9050 - Innovative Technical Systems

    The Innovative Technical Systems ITS-9050 Detector is a sensitive, harmonic mixing detector designed to measure millimeter-wave free-space radiation. It is ideal for measuring radiation patterns of antennas inboth the near and far-field. The ITS-9050 employs a free-running dielectric resonator oscillator (DRO) and an integrated harmonic mixer with a waveguide RF input that either connects directly to a circuit under test or to an antenna for radiation detection. The resulting IF is amplified and detected by an IF log-detector that drives a front panel LCD voltmeter to provide an indication of signal strength. A DC output voltage from the log detector is available on a BNC connector to drive external data acquisition instrumentation. Also, a sample of the IF output is provided for measurement on a spectrum analyzer.

  • Resistance Measurement

    PROMET - KoCoS Messtechnik AG

    High-precision micro-ohm measuring systems with adjustable DC test current for determining resistances on circuit breakers or inductive loads such as transformers, for example. The high-precision ohm meters of the PROMET series are used to determine very low electrical resistances in the µΩ range. The adjustable test current of up to 600 A in combination with a four-wire measuring method delivers measurement results which meet stringent accuracy requirements. State-of-the-art power electronics coupled with a robust design guarantee excellent reliability for use as a portable device in switching stations and industrial environments. Typical applications include determining the contact resistance of switchgear devices and determining the resistance on inductive loads such as transformers.