  • Oil Immersed Test Transformer

    SG-YD - Wuhan Sangao Electrical Test Installations Limit Co.

    AC and DC test oil immersed transformer.Traditional oil immersed test transformer is used to do power frequency withstand voltage and DC current withstand voltage test for variety kinds of high voltage electric device, insulating material.YD series oil transformer, also known as test booster, which test insulation strength under specified voltage for various electric products, components, insulation materials. It can test products insulation level, find insulation defect and judge overvoltage ability. It is widely used in power station, power supply and distribution system and research institute.

  • MCB Thermal Trip Calibration Test Bench (IEC 60898 Cl 9.10.1.2, Annex I.1, IS)

    SCR ELEKTRONIKS

    The test system is designed and customized to carry out 2.55*Intest as per Table 7 (test c) of IEC 60898 (also mentioned for routine testing of MCBs. The test is done at dc current to exactly analyze and correct the bimetallic properties of the MCB as far as thermal tripping is concerned. The unit comes with a pneumatically operated test fixture with in-built dc stepper motor that is controlled by a micro controller / PC to calibrate the breaker into a narrow tripping band programmed by the user.

  • Cable Test Van

    ETL-35 - Kharkovenergopribor Ltd.

    ETL-35 is a cable test van designed for testing electrical substation equipment.Apart from cable insulation withstand testing with DC (rectified) voltage up to 60 kV and ability to measure very small leakage currents, the system can be used for testing various objects with small electrical capacitance with AC voltage of up to 100 kV and measuring dielectric dissipation factor (Tan Delta) at industrial frequency.

  • Cantilever Probe Cards

    Venture - SV Probe, Inc.

    SV TCL's VentureTM line of cantilever probe cards, represents the finest epoxy technology on the market and are perfect for logic testing. The Venture line includes an extensive array of cantilever cards, single to multi-die for a variety of test systems. Our Venture FX™ fine pitch cantilever cards are ideal for LCD driver testing, with higher probe counts for greater density bond pad layouts.

  • Chambers and Glove Boxes

    Electro-Tech Systems, Inc.

    Standard Environments: ETS' multi-purpose benchtop units for laboratory and production use are large enough to accommodate testing and fabrication, as well as storage of materials, test equipment, and assemblies, yet they are small enough to fit on a standard workbench. The systems are able to independently maintain humidity from <5% to >95% RH and temperature from -22F to 122F (-35 to 50C) when unit is placed in an ambient environment location.

  • Catena 1910 HSIC Tester

    Catena 1910 - MCCI

    The MCCI Catena 1910 HSIC USB Tester enables testing of HSIC Host or HSIC Device products. It can be used to exercise your product by operating as an active host or active device, while simultaneously capturing USB traffic for analysis. For test and validation of a final system, Passive Capture mode lets you debug and verify communication between your HSIC Host and HSIC Device,

  • Service, Modernization, and Calibration Serivices

    TIRA GmbH

    In addition to production of new material testing machines, TIRA offers inexpensive service, modernisation and calibration. Our modular design makes it possible to modernise complete measuring technologies, electromechanical and hydraulic material testing machines in a cost-efficient manner.According to all requirements of force-measuring systems DIN EN ISO 7500-1, calibration DIN EN ISO/IEC 17025 and test options according to EN 10002.

  • Comprehensive Oil Analyzer For Industrial Machinery Print

    MiniLab 153 - Ametek Spectro Scientific

    With four simple tests, the MiniLab 153 delivers comprehensive on-site oil analysis, providing immediate actionable results, saving time and reducing costs. Highlights of this system include:*One product, delivering lab-quality analysis outside of the lab*Simplified workflow for the non-expert user, no chemist required *Simplified operation, data reporting and report interpretation via the TruVu 360 Diagnostic Sets with recommended actions.

  • On-Site Oil Analyzer

    MiniLab 23 - Ametek Spectro Scientific

    With two simple tests, the MiniLab 23 delivers on-site oil analysis, providing immediate actionable results, saving time and reducing costs. Highlights of this system include:*One product, delivering lab-quality analysis outside of the lab*Simplified workflow for the non-expert user, no chemist required *Simplified operation, data reporting and report interpretation via the TruVu 360 Diagnostic Sets with recommended actions.

  • On-Site Oil Analyzer

    MiniLab 33 - Ametek Spectro Scientific

    With three simple tests, the MiniLab 33 delivers on-site oil analysis, providing immediate actionable results, saving time and reducing costs. Highlights of this system include:*One product, delivering lab-quality analysis outside of the lab*Simplified workflow for the non-expert user, no chemist required *Simplified operation, data reporting and report interpretation via the TruVu 360 Diagnostic Sets with recommended actions

  • Goniophotometer

    PIMACS CO., LTD.

    A goniophotometer is a system to measure the luminous intensity of the source (or illuminance from the source at a given distance) in many different directions from the source. Compared with the sphere method, the goniophotometer method is theoretically free from errors due to differences in intensity distribution of the light source under test. It is applicable to acquire the luminous intensity distribution, luminous flux, spatial color distribution, and luminance distribution of lamps and luminaires.

  • Transformer Resistance Testing

    Weshine Electric Manufacturing Co., Ltd

    Transformer insulation resistance deterioration is one of the most common causes of transformer failure: a failing transformer is a costly replacement in an electrical system with the potential for a long downtime. If you fail to maintain your transformer with regular insulation resistance testing (as can be carried out by the WESHINE Transformer Ohmmeter (VS-3110 series) of transformer test equipment) then it’s likely to fail before reaching its maximum operating life.

  • Amplified Noise Modules

    NC1000 Series - Noisecom

    The NC1000 Series amplified noise modules produce AWGN as high as +13 dBm, and have bandwidths up to 10 GHz. The high power modules are designed to test noise immunity for Cable TV equipment, secure communication channels, and military jamming systems. The lower power modules, <= 0 dBm, are random jitter sources for many applications including, PCIexpress, Infiniband, and 10 GigE.

  • Air Data Calibrator

    ADC-2500 - TestVonics, Inc.

    TestVonics ADC-2500 Air Data Calibrator is a high accuracy pitot static calibrator. The ADC-2500 is capable of controlling and measuring Altitude and Airspeed pressures with the highest degree of accuracy. The control and measurement range of the test system can meets or exceed requirements for both commercial and military application. The ADC-2500 is currently used by all USAF PMEL organizations as well as various other commercial and military organizations worldwide.

  • Power Distributions

    LXinstruments GmbH

    LXinstruments Power Distribution Units (PDU) provide all of the functionality required to power a test system in a compact 19-inch rack. This means that devices can be supplied with both mains voltage and DC voltage. With the soft-on-off function, the PDU can be controlled remotely via remote buttons and other potential-free contacts. We carry single-phase devices for the 16 A connection to three-phase devices for the 3x63 A or for the 125 A connection.