Filter Results By:

Products

Applications

Manufacturers

Showing results: 1021 - 1035 of 1068 items found.

  • NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module

    783863-02 - NI

    8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • Differential Voltage Probes

    DP150/DP200pro - Powertek LLC

    The DP differential isolation probes are an important accessory for any laboratory involved in power electronics and high voltage systems. These probes allow isolated and floating measurements with any oscilloscope or data recorder, whilst the oscilloscope can remain grounded. Using a DP150 or DP200pro probe, differential and floating measurements can be made on a variety of ac power systems like 230V/110V ac input power supplies, chopped and switching power supplies, thyristor controllers, variable speed motor drives (PWM signals), motor inrush current and measurement across current shunts. The isolated input is made via two 4mm/banana safety sockets. The BNC output allows easy connection to an oscilloscope. The DP probes can be powered from a 9V battery or external power supply.

  • Functional Systems

    PTE-100 - SEICA SpA

    The PTE-100 gives test personnel access to electrical signals for probing, voltage injection, isolation checks, voltage/current and time/frequency measurements, and it offers the ability to analyze hot and loaded circuits, verifying missing, corrupted or present valid signals. Furthermore, the PTE-100 offers the ability to make electrical verification activities more efficient, repeatable and safe, by introducing software controlled test sequences to reduce human errors and guide diagnostic resolution. Break Out Boxes are commonly made in-house and are often specific to a particular project. They are simply designed to multiplex connections between two units and use external instrumentation for signal injection or measurement. The end result is a multitude of tools, difficult to maintain, with limited transportability, providing costly and inefficient operations at the factory or in the field.

  • Vibration Unit Tester

    BK2020B - BaKo Co., Ltd

    We developed the BK2020B as an upgrade to our BK2020 to test the electrical specifications (RPM, current, drop pulse, start up voltage) of your cylindrical or coin type vibration units. You can also test vibration level, noise, isolation resistance, and the DC resistance. The DUT power supply and all measurement components are self contained, so external devices aren't needed and the tester uses DSP, making it capable of fast, highly accurate and reliable measurements. The BK2020B is very versatile. It can be set up as a stand alone machine, or used with a PC and software for access to more information, and to save the data for analysis. Either version is great on the product line but you may also use it for QA, QC and development.

  • Test System Optimized for High Volume Production Testing of Integrated Circuits

    ETS-364 / ETS-600 - Teradyne, Inc.

    The ETS-364 is a general-purpose precision analog and mixed-signal test platform designed for high volume production testing of integrated circuits; optimized for high throughput applications with a fully integrated multisite software and hardware architecture. The test system offers separate floating resources for each site, improving site isolation and measurement accuracy coupled with digital instrumentation enabling the most efficient, high-volume testing available. The system supports up to 240 analog pin channels, and offers 133 MVPS digital vector rate with up to 128 digital pin channels. Eagle's scalability includes the ability to double the capacity of an ETS-364, providing more than 480 analog pin channels and up to 256 digital I/O pin channels with the ETS-600.

  • PXI-2549, 2.7 GHz, 50 Ω, Dual-Terminated SPDT PXI RF Relay Module

    778572-49 - NI

    2.7 GHz, 50 Ω, Dual-Terminated SPDT PXI RF Relay Module - The PXI‑2549 is a general-purpose single‑pole double‑throw (SPDT) switch module. You can use it to add flexibility to your switch network or to maintain uniform signal paths across multiple channels when building high‑channel‑count multiplexers. The PXI‑2549 termination resistors minimize reflections on open channels and protect your source or device under test from damage. The module also features excellent insertion loss, voltage standing wave ratio (VSWR), and isolation parameters to minimize signal degradation. You can use its onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.

  • PXI RF Relay Module

    NI

    PXI RF Relay Modules offer single-pole double-throw (SPDT) and terminated switches. SPDT models include excellent insertion loss, voltage standing-wave ratio (VSWR), and isolation parameters to minimize signal degradation. You can use the onboard relay-count-tracking feature on these models to predict relay lifetime and reduce unexpected system downtime. SPDT models are also well-suited for passing high-order harmonics from PXI RF Signal Upconverter Modules or routing multiple sources to PXI RF Signal Downconverter Modules. Terminated switch models feature front-mounted SMA connectors and high-performance solid-state relays for fast switching time and unlimited mechanical lifetime. These models also include termination on every COM line and channel, which helps minimize reflections of the RF signal and protect your instruments.

  • Magnetic Level Gauge Switches

    ABB Ltd.

    ABB's magnetic level gauge switches for point level alarm and/or control can mount to a KM26 magnetic level gauge or an LS Series cage level switch.These switches are completely isolated from the process fluid as they are magnetically activated by a magnet equipped float (KM26) or attraction sleeve (LS Series). The unique magnetic coupling action eliminates seals, diaphragms, springs, and torque tubes common to other level switching alternatives since there is no physical contact with the process fluid. The magnetic coupling also eliminates process connections to the switch; therefore, no isolation valves are required to block off the switch for maintenance. The switch "set point" is easily adjustable without changing any process piping and the result is a more reliable and easier way to maintain level system.

  • Faraday Cages

    LBA Group, Inc

    LBA's EMFaraCage® faraday cages are EMI and RFI shielding boxes and RF test enclosures that bring convenience to device testing. Faraday cages are ideal for isolating critical systems in high field RF environments or wherever RF ingress or egress must be minimized. Security, production testing, biomedical research and semiconductor testing are only a few of the many areas where EMFaraCage® faraday shielded enclosures are employed. EMFaraCage® faraday cage enclosure systems are fully featured to support a wide variety of test missions. The standard faraday cages include effective power, dataline and RF signal isolation in large test volumes. EMFaraCage® faraday cages are much more affordable than shielded room solutions and offer the convenience of portability.

  • Microwave Wideband Synthesizer w/ Integrated VCO

    ADF5356 - Analog Devices Inc.

    The ADF5356 allows implementation of fractional-N or integer-N phase-locked loop (PLL) frequency synthesizers when used with an external loop filter and an external reference frequency. The wideband microwave VCO design permits frequency operation from 6.8 GHz to 13.6 GHz at one radio frequency (RF) output. A series of frequency dividers at another frequency output permits operation from 53.125 MHz to 6800 MHz. The ADF5356 has an integrated VCO with a fundamental output frequency ranging from 3400 MHz to 6800 MHz. In addition, the VCO frequency is connected to divide by 1, 2, 4, 8, 16, 32, or 64 circuits that allow the user to generate RF output frequencies as low as 53.125 MHz. For applications that require isolation, the RF output stage can be muted. The mute function is both pin- and software-controllable.

  • Medical Leakage Current Tester

    2675Y - Shenzhen Chuangxin Instruments Co., Ltd.

    The 2675Y Medical Leakage Current Tester Series Is The Test Equipment Used For Measuring Continuous Leakage Current And Patient Auxiliary Current Of Medical Electrical Equipment.It Designs And Products According To The GB9706.1_2020 (IEC60601-1:2012) .And The Test Circuit (MD)Input Impedance To Simulate The Body Impedance,It Accord With The Requirements Of GB9706.1-2020 (IEC60601-1:2012),The Test Current Can Run Up To 5A,And Provide Users With An Isolation Power Supply Which Adjustable Output Voltage For 0~250V Continuously Of The Basic Capacity Configuration For The 500VA And Provide Another 110% Voltage Source Of The Maximum Rated Voltage.It Can Satisfy The I,II, Various Types Of Equipment Test The Earth Leakage Current,Shell Leakage Current,Patient Leakage Current,Patient Auxiliary Leakage Current Under Normal Condition And The Single Fault.

  • C Series Current Output Module

    NI

    The C Series Current Output Module features up to eight channels of simultaneous analog output. You can choose between enclosed and non-enclosed modules. Additionally, the C Series Current Output Module has built-in open-loop detection. This detection generates an interrupt in software when an open loop is detected, zeros outputs to ensure safety, and avoids driving actuators at system power-on. The C Series Current Output Module requires an external power supply and includes a channel-to-earth ground double isolation barrier for safety and noise immunity.The C Series Current Output Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.

  • Build Your Hydrostatic Tester

    Hydraulic Technology, Inc.

    Start with the basic Model 9901 hydrostatic tester as shown to the left with the following standard equipment:- Hydrostatic test pump, air operated.- 1% ANSI B40.1 Grade 1A stainless steel high pressure gauge.- ANSI B40.1 Grade B air pressure gauge.- Micro adjust precision regulator.- High pressure isolation shutoff valve.- Automatic lubricator.- Stainless steel high pressure manifold.- 1/4" NPT accessory port.- Bleed valve.- Air shutoff valve.- Factory set air pressure relief valve.- 7/16-20 straight thread O-ring boss outlet port (MS33649-04) with -4 male adapter fitting.- 3/4" swivel female hose inlet with strainer.- Stainless steel base plate with rubber feet.

  • Transceiver Module

    Mornsun Guangzhou Science & Technology

    MORNSUN transceiver modules include integrated high efficiency CAN, RS485, RS232 isolated transceiver module, protocol conversion module and serial port to ethernet transceiver module. These industrial bus transceiver with DIP, SMD, SOIC and DFN optional packages features compact size, surge and ESD bus protection, a maximum isolation voltage up to 5,000 VDC and a wide operating temperature range of -40°C to 85°C, even up to 105°C, etc. Coupled with the use of IC integrated technology,  the isolated transceiver module can easily be embedded in the user's end equipment, and achieve fully-functional bus network connectivity and data communication. Check out these isolated transceiver modules with a reasonable price along with high performance and we hope that they are an ideal fit for your application needs.

  • Thermal/Multi-Function Data Logger

    51101 - Chroma Systems Solutions, Inc.

    Models with 1, 8, and 64 channels on-line data recording. Multi-sets linked to a PC for hundreds of channels are doableSupports B, E, J, K, N, R, S, and T type thermal couples with ITS-90 defined temperature rangeIndividual channel cold junction compensation withTemperature resolution up to 0.01℃, error down to (0.01% of reading+0.3℃)Voltage full range ±480VDC, ±10VDC; resolution 1mV, 10uV; error down to (0.1% of reading+1mV), (0.015% of reading+100uV)1000VDC channel to channel isolation, full protection for testing points with charge and guarantee for accurate measurementsThermal couple open circuit detectionPC-based operation with powerful software for recording and analyzing data1 and 8 channel models are USB powered. No battery or external power supply is required

Get Help