Showing results: 271 - 285 of 1082 items found.
-
780180-01 -
NI
±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module - The NI‑9229 performs differential analog input. The NI‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating.
-
779785-01 -
NI
±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module - The NI‑9229 performs differential analog input. The NI‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating.
-
779785-02 -
NI
±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module - The NI‑9229 performs differential analog input. The NI‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating.
-
Educated Design & Development, Inc.
Up to 8 resistance reading channels, 4-wire methodUp to 12 temperature reading chanels, use of Type K, 24 AWG, Teflon thermocouplesIn the Box:8 - data cable (Cat5e) to connect the isolation modules to the Resistance Reading Channels8 - Isolation Module connected between the HOT-30 and EUT (Equipment Under Test) to isolate high voltage8 - Banana Jack Sets (2 red, 2 black), to replace Kelvin Leads in tight places8 - Kelvin Probe Set12 - 72 inch K Type Thermocouple1 - USB2.0 Type A (standard) to Type B USB cable
-
DSI International
The Integrated System Diagnostic Design or ISDD Tool Suite provides a start to finish solution for meeting all the diagnostic needs of system design. The ISDD design process is centered around functional modeling of systems which is used to develop the diagnostics and failure analysis necessary to fully support good system design. This includes: *Analysis of Fault Detection and Fault Isolation.*Analysis of critical failures and their impact upon safety.*Detecting and reducing false alarms caused by diagnostics.*The impact of prognostics upon fault detection/fault isolation and mitigation of critical failures.*Development of vehicle health management and troubleshooting diagnostics
-
Pulse Electronics
Common Mode Chokes, as the name implies, are designed to attenuate and filter common mode noise within an electric system. The key parameters for a common mode choke are the current rating (to ensure the part does not overheat within the application), the impedance versus frequency (to ensure it is optimized to attenuate the desired frequencies), the isolation voltage (to ensure it meets board level requirements between the line and neutral phases) and safety isolation (to ensure it meets the safety requirements of the end-application). It is important to remember that common mode chokes cannot saturate in the application (under normal use) as they are designed to ensure that the line and return currents are balanced.
-
APCI-1016 -
TEAM SOLUTIONS, INC.
*16 digital inputs, 24 V Optical isolation 1000 V Input filter*Protection against pole reversal*Standard drivers for:*Real time drivers for Windows 2000/NT/98.*The board is supplied with the universal software ADDIPACK.
-
Entes Elektronik
ENTES LV Current Transformers are measuring transformers which transform the primary current by a specified ratio to its secondary side with a phase difference of 0 degrees. They provide isolation of the relays and measuring devices from the HV side of the network.
-
WD5943 -
Hangzhou Huatai Optic Tech. Co., Ltd.
WD5943 WDM is based on mature thin film filtering tech, with wide bandwidth, flatness, low insertion loss and high isolation. It is mainly applied to FTTx PON network to achieve the combination and separation of the 1550nm (CATV) and 1310/1490nm (data).
-
WD5643 -
Hangzhou Huatai Optic Tech. Co., Ltd.
WD5643 WDM is based on mature thin film filtering tech, with wide bandwidth, flatness, low insertion loss and high isolation. It is mainly applied to FTTx PON network to achieve the combination and separation of the 1550nm (CATV) and 1310/1490nm (data).
-
QM Series -
TDK-Lambda Corp.
*Up to 18 Outputs*Full Medical Isolation (MOPP)*Low Speed, Low Audible Noise Fan*Industry Leading Flexibility*7 year warranty*Suitable for B and BF rated equipment*PMBus™ communication option
-
iEA Series -
TDK-Lambda Corp.
*Standard Eighth Brick Footprint*36-75 Vdc Input*5, 12, 15, 18 and 28 Vdc Outputs*1500 Vdc Isolation*-40 to 125 °C Operating Temperature*Constant Switching Frequency*Constant Switching Frequency
-
PXF Series -
TDK-Lambda Corp.
*Industry Standard 2" x 2" Footprint*9-18, 9-36, 18-36, 18-75 Vdc Inputs*Single, Dual and Triple Outputs*1600 Vdc Isolation*-40 to 100 °C Case Temperature*Six-sided Shielding*EN61000-4 Immunity
-
DPX Series -
TDK-Lambda Corp.
*Single, Dual and Triple Outputs*9.5-36 Vdc, 18-75 Vdc Inputs*Meets EN55022 Class B*1600 Vdc Isolation*-40 up to 95 °C Operating Temperature*EN61000-4 Immunity*Narrow 24.5 mm width
-
PH-A Series -
TDK-Lambda Corp.
*Standard Quarter / Half Brick Footprint*200-425 Vdc Input*3.3, 5, 12, 24, 28, 48 Vdc Outpouts*3000 Vac Isolation*-40 to 100 °C Baseplate Temperature*Certified to IEC/EN62477-1 OVCIII