Showing results: 871 - 885 of 1082 items found.
-
QTOUCH2404C -
Qmax Test Technologies Pvt. Ltd.
Qtouch2404C – Automated Bare Board Tester with in-built camera is designed to make automatic image capturing and probing of bare PCBs. It is designed to move on X,Y,Z directions making it possible to probe every test point. Flying Probe Tester is designed for testing high density fine pitched Single Sided / Double Sided and Multilayer PCBs for continuity and isolation using moving probes fixture –less technology.
-
SMX-4XXX (Matrix Switches) -
AMETEK VTI Instruments
The VTI SMX-4xxx Series of matrix cards deliver exceptional performance and reliability by implementing extensive signal path shielding, isolation and built-in health monitoring. Available models with software configurable switch subsystems increase flexibility and help control costs by allowing a single module to be used for different testing requirements. Embedded virtual schematic control further simplifies setup and debugging, allowing all relays to be engaged independent of application software.
-
34947A -
Keysight Technologies
The Keysight 34947A microwave switch for the 34980A Multifunction Switch/Measure Unit offers bi-directional switching for test signals from DC to 26.5 GHz. These switches provide excellent insertion loss, isolation, and VSWR specification. The microwave switches are configured as three independent 1x2 (SPDT) unterminated switches on a single module. For general-purpose microwave switching applications, the module can be used to switch separate signal sources for a multi-band receiver/transmitter testing application.
-
782385-07 -
NI
The TB-2643B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 4x64 or 1-wire dual 4x64 matrix. You can directly connect the TB-2643B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2643B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
782385-08 -
NI
The TB-2643B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 4x64 or 1-wire dual 4x64 matrix. You can directly connect the TB-2643B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2643B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
782385-09 -
NI
The TB-2644B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 8x32 or 1-wire dual 8x32 matrix. You can directly connect the TB-2644B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2644B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
34946A -
Keysight Technologies
The Keysight 34946A microwave switch for the 34980A Multifunction Switch/Measure Unit offers bi-directional switching for test signals from DC to 26.5 GHz. These switches provide excellent insertion loss, isolation, and VSWR specification. The microwave switches are configured as two independent 1x2 (SPDT) terminated switches on a single module. For general-purpose microwave switching applications, the module can be used to switch separate signal sources for a multi-band receiver/transmitter testing application.
-
782385-11 -
NI
The TB-2645B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 16x16 or 1-wire dual 16x16 matrix. You can directly connect the TB-2645B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2645B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
782385-12 -
NI
The TB-2645B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 16x16 or 1-wire dual 16x16 matrix. You can directly connect the TB-2645B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2645B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
782385-10 -
NI
The TB-2644B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 8x32 or 1-wire dual 8x32 matrix. You can directly connect the TB-2644B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2644B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
782999-01 -
NI
The NI‑9482 directly connects to a wide array of industrial devices such as motors, actuators, and DC devices. Each channel provides access to an electromechanical relay for switching signals up to 60 VDC (1 A) or 250 Vrms (1.5 A), features channel‑to‑channel isolation, and has a LED that indicates the status. The shock and vibration rating for the NI‑9482 is limited compared with other CompactDAQ and CompactRIO modules because of the mechanical relays on the module.
-
T1000-37 -
Tesuto Systems
T1000-37 breakout box is our most versatile model, using dual 37 pin D-Sub connectors for signal capture or monitoring. Dual connectors provide a total of 74 test points plus a ground jack. All test points use standard size 4mm banana jacks. Test points may be connected using shorting banana cable to allow signal continuity. Ideal for continuity measurements, isolation testing, and signal capture.
-
40-652-002 -
Pickering Interfaces Ltd.
The 40-652 range of multiplexers uses solid state relays with high tolerance to surge currents and hot switching events. Each multiplexer provides an isolation relay in the common to minimize capacitive loading when expanding the multiplexer across multiple modules. The 40-652 can sustain 30A for 300s on hot or cold switching. User connections are made via a 50-way D-Type connector which is fully support by our comprehensive range of cables and connector accessories.
-
40-652-101 -
Pickering Interfaces Ltd.
The 40-652 range of multiplexers uses solid state relays with high tolerance to surge currents and hot switching events. Each multiplexer provides an isolation relay in the common to minimize capacitive loading when expanding the multiplexer across multiple modules. The 40-652 can sustain 30A for 300s on hot or cold switching. User connections are made via a 50-way D-Type connector which is fully support by our comprehensive range of cables and connector accessories.
-
40-652-001 -
Pickering Interfaces Ltd.
The 40-652 range of multiplexers uses solid state relays with high tolerance to surge currents and hot switching events. Each multiplexer provides an isolation relay in the common to minimize capacitive loading when expanding the multiplexer across multiple modules. The 40-652 can sustain 30A for 300s on hot or cold switching. User connections are made via a 50-way D-Type connector which is fully support by our comprehensive range of cables and connector accessories.