FFA-2 -
Langeo Co., Ltd.
FFA-2 quick α digital scintillation actinography is designed to measure α ray intensity in soil sample or on α cards for the purpose of locating geological structure, such as concealed fault, fissure, fracture zone, underground water reservoir, and the tectonic cloud of the natural gas and oil. It can also be used to engineering geology exploration, the deep uranium mineral ore, regional radon detection (environmental protection detection), and trace original gold vein.
-
InfraTec GmbH
Due to their spectral properties and robustness, pyroelectric detectors have proven themselves for many years in numerous applications in gas analysis, flame detection and spectroscopy. They enable the tuning of the optical filter over a defined spectral range by simply adjusting the control voltage. Instead of mounting filters to inspect specific areas of interest as is conventionally common, the detector with tunable Fabry-Pérot filters (FPF) can be used to monitor a broad spectral region continuously.
-
KANOMAX USA, Inc.
Maintaining proper indoor air quality (IAQ) has only become more important in recent years as personal health and comfort have become a higher priority than ever before. Our testing and monitoring instruments for IAQ, including our indoor air quality monitors, gas monitor, and odor meters help industrial hygiene and HVAC professionals test and monitor environments to solve crucial air quality problems.
-
CZ1803 -
Aegis Pty. Ltd.
The CZ1803 is an inductive antenna accessory used to put a signal on any pipe or cable without having to make direct connection to that pipe or cable. You can simply plug the Inductive Coupler into the transmitter and your signal will be transmitted onto your target pipe or cable. When used with the TraceAll locator system, this inductive coupler is suitable for locating all services such as data, electrical, television, telecommunications cables and gas and water pipes.
-
MKS Instruments
The 835 VQM is a mass spectrometer that operates from UHV to 10-5 Torr and accurately measures the gases in the vacuum chamber. The 835 VQM Differential Pump System delivers the advantages of the 835 VQM at higher pressures. The VQM system consists of an autoresonant ion trap mass spectrometer gauge, a VQM Controller and VQM Viewer software that that converts raw data into actionable information. The system is ratiometric, meaning that it determines the ratio of each gas to other gases in a vacuum chamber. It is usually coupled with a total pressure gauge to provide partial pressures of each gas as indication of the quality of the vacuum in the chamber.
-
CEMS-2000B -
Focused Photonics Inc.
Mercury analyzer applies cold vapor atomic fluorescence technology(CVAFS), integrated with dilution samplingsystem to eliminate interference with background components and ensure reliable performance. Automatic calibration of mercury check with internal CAL-200 calibration gas generator.
-
CA3006 -
UC Instruments, Corp.
CA3006 OFFSOON Endface Cleaner is a fiber endface cleaner for cleaning transceiver modules or components. By using pure liquid and gas, OffSOON shoots liquid to dissolve oil and dirt and blow the end face with air stream to remove the liquid and dirt and make the endface clean. The whole process just need 1 seconds. OFFSOON comes along with SC and LC type adaptors and fulfill almost every customer’s need for connectors cleaning jobs.
-
DT3000 -
Datatest Inc
The Datatest Model DT3000 is a Zirconia sensor, microprocessor based, oxygen analyzer. The DT3000 comes with probe configurations for temperatures up to 3200F. The microprocessor based controller provides long-term stability and reliability, plus optional features for controlling back purge, calibration gas injection, and self-calibration. 4 - 20 mA output and Modbus RTU serial port are standard. The DT3000 is available in either a NEMA 4 wall mount or panel mount configuration.
-
PGM-IR -
Bacharach, Inc.
The PGM-IR portable refrigerant monitor offers superior performance and functionality for low ppm level leak detection of refrigerants, Carbon Dioxide, Nitrous Oxide or Sulfur Hexafluoride. A built-in library of 60+ refrigerants enables the PGM-IR to accurately detect the smallest leaks at their source. The unit is immune to sudden changes in temperature or humidity and to over-exposure. The PGM-IR requires no zeroing of positive readings with extended exposure to gas. It has a data logging capacity of up to 200 readings.
-
Series 490A -
Dwyer Instruments Inc.
Liquid & Gas Pressure Measurement, ±0.5% FS Accuracy. The SERIES 490A Digital Manometers are versatile, hand-held, battery operated manometers available in several basic ranges for positive or positive differential pressure measurement and can tolerate most liquid media compatible with 316LSS. A new feature added to the Series 490A is a field adjustable damping, which allows the user to choose the level of display averaging rate corresponding to the fluctuation level common in many applications.
-
Rocky Mountain Laboratories, Inc.
Rocky Mountain Laboratories, Inc. provides SEMI Standards analyses that conform to the following SEMATECH and SEMI Standards for testing of passivated 316L stainless steel components being considered for installation into a high-purity gas distribution system:SEMASPEC #90120401B-STD (SEM Analysis)SEMASPEC #90120402B-STD (EDS Analysis)SEMASPEC #90120403B-STD (XPS Analysis)SEMASPEC #91060573B-STD (Auger (AES) Analysis)SEMI F60-0306 (based on F60-0301) (XPS Analysis)SEMI F72-1102 (Auger (AES) Analysis)
-
HY-OPTIMA™ 700B Series -
H2scan Corp.
H2scan’s HY-OPTIMA™ 700B series in-line, real time hydrogen-specific process analyzers are designed for ease of use, interface flexibility and true process control. The HY-OPTIMA™ 700B series is a solid-state sensor that is configured to operate in process gas streams with temperatures up to 60ºC. The HY-OPTIMA™ 700B series is ideal for hydrogen production and petrochemical applications where real-time measurements can enhance process plant efficiencies, diagnostics and maintenance management.
-
AC560000 -
Matco Tools
Fast, economical and accurate method to test for combustion gas leaks in head gaskets, cylinder heads and engine blocks. Dual chamber design provides more accurate test results. Test fluid can be used for both gasoline and diesel engines.
-
Ion Science, Ltd.
ION Science is a leading manufacturer of VOC gas sensors, with PID sensor technology trusted by major gas detection manufacturers globally for accurate detection of volatile organic compounds (VOCs). To the ever-growing sensing portfolio, ION Science offers Development Boards and Kits specially designed to offer OEMs at a simple, low-cost with means of integrating MiniPID sensors into existing systems and applications. Due to tightening legislation and the growing global focus on air quality, worker safety and environmental emissions are driving the requirements for a new generation of measurement and monitoring systems. The multi-award-winning Disc Pumps are now available and distributed by ION Science.
-
CEA-100 -
Walsn Enterprises Ltd.
Walsn CEA - 100 combustion efficiency analyzer is designed to continuously monitor CO content in flue gas while the measurement data can be used to adjust the ratio of fuel/ air so as to achieve the maximum boiler efficiency for boiler operation. Walsn CEA - 100 adopts the dual-measuring-sensor technology and features high accuracy with low zero drift and very small failure rate, matching the requirements of the harsh industrial environment. It is also easy to install and maintain.