Filter Results By:

Products

Applications

Manufacturers

Gas

1) fills any space it's contained in and is amorphous. 2) liquid fuel powering vehicles.

See Also: Dissolved Gas, Gasoline, Ammonia


Showing results: 1201 - 1215 of 1389 items found.

  • Electrochemical (Molecular Electronic Transfer) Motion Sensor transducers

    The Molecular Electronic Transfer Technology

    The basic design of the MET transducer, shown in Figure 1. The transducer is contained in a channel, 1, of a sensor filled with a specially prepared electrolytic solution. It consists of four fine platinum mesh electrodes, two anodes, 2, and two cathodes, 3, separated by thin, microporous ceramic or polymer spacers 4. Such an assembly is held together by a housing 5. To measure the motion of the fluid, it must be converted into an electrical signal. One way of achieving this is by using the convective diffusion of the ions in the electrolyte. At the heart of a MET device are inert electrodes at which a reversible redox reaction occurs, which does not involve either plating of a metal or evolution of a gas.

  • Portable 4-Gas Monitor

    PS200 - Teledyne Gas & Flame Detection

    The PS200 Series combines quality, ruggedness and advanced technology in a user friendly, portable gas monitor. It is compact, lightweight, water resistant, extremely robust, and is certified to multiple international and regional standards.The PS200 can measure any combination of LEL, ​O2, CO and H2S making it suitable for a wide range of personal monitoring and confined space applications.In addition to extensive datalogging capabilities, the PS200 is available with an optional internal pump and an extensive range of accessories to meet a wide variety of user applications.Importantly, the PS200 has been des​​igned to enable easier user maintenance which includes a fully automatic calibration station to simplify product compliance.

  • Utility Locator

    VM-850 - Vivax-Metrotech Corp

    Using the correct frequency makes a world of difference when locating buried utilities. The depth of the utility, size, material, and amount of congestion (proximity of other utilities) all need to be taken into consideration for the correct frequency selection. Large diameter, direct buried pipes with bell housing ends that use insulators and rubber gaskets, such as water or gas require a higher frequency while smaller diameter, well-grounded direct buried or long distance in conduits work, better with a lower frequency. The VM-850 operates at a much lower frequency of 9.82kHz which is ideal for smaller diameter utilities such as CATV, power and telephone with less bleeding onto adjacent services.

  • Analytical Techniques

    Anderson Materials Evaluation, Inc.

    Our numerous analytical techniques, we tackle a wide range of materials challenges and commonly combines several analytical techniques to fully address complex and multi-dimensional materials issues.  Our materials analysis laboratory provides XPS surface analysis, thermal analysis (TGA, DSC, TMA), FTIR infrared spectroscopy, UV-Vis spectrophotometry and reflectivity measurements, gas chromatography – mass spectroscopy (GC-MS), SEM/EDX, optical microscopy, mechanical testing, electrochemistry and corrosion analyses, residual gas mass spectroscopy, contact angle measurements, surface contamination measurements, adhesive bonding failure analysis, facility testing for silicone contamination, mechanical testing, metallography and fractography, density and porosity measurements, volatile organic component testing, friction, and other analytical capabilities.  We continue to upgrade and expand our arsenal of analytical techniques and custom analytical methods to support our customers’ needs.

  • High Range UV Fluorescence SO2 Analyzer

    Model N100H - Teledyne Advanced Pollution Instrumentation

    The Model N100H instrument uses the proven UV fluorescence principle, combined with a state-of-the-art modular architecture, and intuitive operating software to provide accurate and dependable measurements of high range SO2 gas. The instrument includes interferent rejection, providing a simple and precise solution for a broad range of continuous emission monitoring systems (CEMS) and stack testing applications.

  • Fluid Power Actuators

    Type K Damper Drives - Rotork plc

    The Type K Range offers rotary and linear pneumatic damper drives for utility power plants, refineries, powerhouse boilers, furnaces and process heaters that require precise combustion air and flue gas handling solutions. Type K damper drives have proven to increase boiler efficiency, reduce maintenance, lower fuel consumption and reduce harmful emissions.

  • Differential Pressure and Temperature Data Logger

    PRTemp1000D - MadgeTech, Inc

    The PRTemp1000D is a rugged pressure and temperature data logger designed to accurately monitor and record pressure and temperature at user programmable reading intervals. The rugged stainless steel design allows for the device to be placed in harsh environments, which makes it well suited for use with air conditioning systems, chilled water, hot water, air, gas, oil and steam pressure systems.

  • Photosynthesis System

    LCpro-SD - Opti-Sciences, Inc.

    The LCpro-SD offers laboratory grade experimental performance in a truly portable device. Featuring ADC's highly accurate miniaturized infrared gas analyzer, the LCpro-SD is, at 4.5kg or 10lbs., less than half the weight and half the size of conventional systems offering full environmental control. Ideal for A/Ci curves, and A/Q curves, measuring step sequences are full programmable.

  • Pressure Calibration Custom Systems

    Fluke Calibration

    Our custom systems integrate standard Fluke Calibration products, pressure generation and control accessories and/or data acquisition hardware to meet customer requirements. Systems may be mobile calibration carts or rack mounted instrument panels or benches. 7250-sys Ruska gas pressure controller system, and engineered systems customized to fit your application needs.

  • Pressure and Temperature Data Logger

    PRTemp1000 - MadgeTech, Inc

    The PRTemp1000 is a rugged pressure data logger designed to accurately monitor and record pressure and temperature parameters at user programmable reading intervals. The rugged stainless steel design allows for the device to be placed in harsh environments, which makes it well suited for use with air conditioning systems, chilled water, hot water, air, gas, oil and steam pressure systems.

  • Vapor Source Mass Flow Controller With Viscous Laminar Flow

    MKS Instruments

    The 1152C Vapor Source Mass Flow Controller is a pressure-based measurement and control system designed to meter and control vapor from low vapor pressure liquid and solid sources directly, without the need of a carrier gas. The 1152C consists of a fixed flow element and two capacitance manometers for flow measurement, with a proportioning solenoid control valve for flow control.

  • Drying Ovens

    Dongguan Amade Instruments Technology Co., Ltd

    Drying oven is divided into fan blown type electric drying oven and vacuum drying oven based on the different materials which are dried. Electric drying oven is an oven with circulating air function to dry materials containing water by the way of electrical heating. Vacuum drying oven is a instrument provides vacuum environment for specially heat dry heat-sensitive, easily decomposed and easily oxidized materials. Working chamber is vacuumed by vacuum pump prior to drying, allowing to be filled with inert gas If necessary. Drying cabinets are widely used in chemical industry, electronic communication, plastics, cables, hardware, automobile parts, rubbers, printing, medical products, academy laboratories etc.

  • Inductively Coupled Plasma Mass Spectrometer

    ICPMS-2030 - Shimadzu Corp.

    With its newly developed collision cell and optimized internal structure, the ICPMS-2030 provides superior sensitivity. At the same time, thanks to the adoption of its proprietary mini-torch unit and provision of an Eco mode, the quantity of argon gas needed for analyses has been greatly reduced to the industry's lowest levels. As a result, low running costs are assured. The Development Assistant function of the software automatically sets the optimal analysis conditions for quantitative analysis. Then, after measurements are complete, the Diagnosis Assistant function automatically checks the validity of the necessary data. While reducing the burden on the user, the efficiency of analyses is enhanced and the reliability of the data can be increased. It complies with FDA 21 CFR Part 11.

  • Rotational Flow Demonstration Kit

    Renesas Electronics Corp.

    The rotational flow demonstration kit detects the rotational position using the MCU’s on board data transfer controller (DTC) function, a form of state machine, while the MCU’s core is in stop-mode state. This ensures that the average power consumption is kept as low as possible, with IAV (average current) at 4.5 microampere (μA) and a 32 sample burst per second. The flow demonstration kit senses the flow direction and volumetric flow rate of water and gas, and can also detect reverse flow. The demonstration kit is applied using an active inductive method. Two coils are used to sense the rotational position of a part-metalized disk, and a third coil is used to generate a reference signal.

  • RH Calibrator / Dew Point Generator

    Edgetech Instruments

    Edgetech Instruments'' portable calibration system offers the highest accuracy available for both relative humidity and temperature. Using chill mirror technology and precision PRT's, Edgetech''s calibrators offer best repeatability, stability and reliability when measuring RH and temperature. The calibrators are used mainly by calibration labs as a reference standard.The Edgetech Instruments dew point generator, DewGen, another calibration lab favorite, can be used as a stand alone or with a NIST traceable chill mirror dew point system creating very accurate dew points or frost points. Depending on the dry gas source this generator can create dew points from +15C to -80C.