Filter Results By:

Products

Applications

Manufacturers

Gas

1) fills any space it's contained in and is amorphous. 2) liquid fuel powering vehicles.

See Also: Dissolved Gas, Gasoline, Ammonia


Showing results: 1141 - 1155 of 1389 items found.

  • Paramagnetic O2 Analyzer Optional CO2 Sensor

    Model T802 - Teledyne Advanced Pollution Instrumentation

    The Model T802 O2 uses the proven paramagnetic measurement principle, coupled with state of the art microprocessor technology, to provide accurate and dependable measurements of Percent-Level O2.Paramagnetic technology is non-depleting, which means that there are no consumable parts, and ensures a consistent performance over time. The selectivity of the paramagnetic measurement for oxygen means that there is little or no interference from other common background gases. The T802 offers a stable and inherently linear measurement of oxygen, making it possible to calibrate the analyzer by checking only two points. There is no requirement for a reference gas during operation.

  • Rotary Encoders

    Dynapar

    Our proven rotary encoder and resolver solutions are used worldwide in a variety of industries such as Medical, Oil & Gas, Aerospace, Packaging, Robotics, Paper and Steel, to name a few. Dynapar''''s vast product portfolio offers a wide selection of incremental and absolute encoders engineered with cutting edge optical or magnetic technology, brushed and frameless resolvers, and accessories. Dynapar offers a wide variety of optical or magnetic shaft encoders and resolvers, as well as any resolver or encoder product your particular application may require.

  • Rapidox OEM solutions

    Cambridge Sensotec Ltd

    At Cambridge Sensotec we have been supplying OEM gas analyser solutions for over ten years. Each OEM customer is given a bespoke scope of supply to match its exact requirements. We produce variations of our OEM electronics removing unwanted components and features to keep costs down and only give the customer the functions it actually needs. Cables, power supplies, board mounts and sensor manifolds are tailored to meet exact OEM specifications and cables are provided at the correct length for the OEM’s application.

  • Ultrasonic Leak Detector

    VPE - Superior Signal Company

    The Patented Superior AccuTrak VPE represents state-of-the-art technology for pinpointing leaks is air conditioning and refrigeration systems. AccuTrak is extremely sensitive to the ultrasonic sound of a turbulent gas leak. Using a technology called "heterodyning" it translates the sound to a lower frequency which your ear can interpret. AccuTrak maintains the original sound characteristics making it possible to distinguish leaks from other competing background sounds. AccuTrak is so sensitive you can actually hear the blink of an eye, yet most background noise will not interfere with detection accuracy.

  • Hyphenated Technology

    PerkinElmer Inc.

    Evolved Gas Analysis (EGA) solutions couple two or more analytical technologies to greatly increase the power of analyses and save precious time by acquiring more information from a single run, creating a powerful and easy-to-use platform for materials characterization. EGA Hyphenation is a powerful tool in the analysis and identification of complex mixtures, both known and unknown, including identifying harmful chemicals in soil, quantitating components in polymers, determining leachables that may contaminate a product's packaging, identifying phthalates in PVC samples and more.

  • Gravimetric Dust Measuring Devices

    SICK Sensor Intelligence

    Easy setup, accurate measurement, rapid resultsGravimetric dust measurement devices extract a partial gas flow from the duct under predefined conditions and use a filter to separate out the dust particles. The amount of dust is ascertained by weighing the filter. The differential pressure is measured to determine the extracted volume. These two values are then used to calculate the concentration of dust in the duct with a high level of accuracy. Gravimetric dust measurement is ideal for calibrating other dust measuring devices and for taking the kinds of comparative measurements that are required by the relevant authorities.

  • Flowmeters

    Parker Hannifin Corp.

    Parker high performance flowmeters provide a consistent line of accurate and efficient measurement solutions that can work with a wide range of industrial media. Choose from our many different types of flowmeter, each adaptable to meet the needs of your application. We also supply PFA and PTFE flowmeters for leak-free, precise control of ultra-high purity liquids and a diverse range of gas mass flowmeters. These enable us to meet demands for expanded flow ranges and high operating pressures, making them suitable for use in extreme environments.

  • 150psi Pressure Transducer

    Extech PT150 - Extech Instruments Corporation

    The Extech PT150 is a Pressure Transducer for 150 psi measurements with the SDL700 Pressure Meter/Datalogger and the 407495 Heavy Duty Pressure Meter with Interchangeable Transducers. For air or non-corrosive/non-ionized gas. 6.4 mm (1/4”) PS, 19 teeth per inch with a 1.2 m (3.9 ft) cable.

  • 30psi Pressure Transducer

    Extech PT30 - Extech Instruments Corporation

    The Extech PT30 is a Pressure Transducer for 30 psi measurements with the SDL700 Pressure Meter/Datalogger and the 407495 Heavy Duty Pressure Meter with Interchangeable Transducers. For air or non-corrosive/non-ionized gas. 6.4 mm (1/4”) PS, 19 teeth per inch with 1.2 m (3.9 ft) cable.

  • Large Electrical Machines Bench Testing

    ViTec Co. Ltd

    The automated system for recording parameters during testing of gas turbine generators consists of several independent but interacting measuring subsystems and a signal conditioning system. The subsystems for recording "fast" signals are implemented on the PXI platform, "slow" signals are registered by a subsystem built on the basis of the Compact FieldPoint platform.

  • Helium Leak Testers

    Yamaha Fine Technologies Co., Ltd.

    Yamaha Fine Tech's proprietary low vacuum test realizes highly reliable measurement. With our proprietary low vacuum chamber system and helium gas detector, highly reliable inspections are conducted. Easy operation and easy maintenance are realized by a full fail-safe and sophisticated control system.

  • Relays & Coax Switches

    Teledyne Defense Electronics

    Teledyne Relays offers high-performance relays designed to survive the rugged conditions required for oil & gas exploration, industrial control, and military & space applications. Teledyne Coax provides RF & Microwave switching solutions for SATCOM, military & space applications, test & measurement equipment, and ATE systems.

  • Portable Analyzers

    Alpha Moisture Systems

    The key to the operation of Alpha Moisture Systems' Portable Analysers is the unique Desiccant Dry-Down Chamber. By keeping the sensor dry between tests, the special assembly of the head ensures that the instrument is always ready for immediate use. The head assembly consists of two chambers which have a telescopic action. When the head assembly is in the 'closed' or 'Dry-Down' position, the sensor is completely surrounded by desiccant, which absorbs the remaining water moisture from the sensor and hence it is dry and ready for use. The small space at the bottom of the test chamber enables the sample pipe to be purged before the test commences without wetting the sensor. By placing a finger over the outlet of the head, the sample pressure is able to open the test chamber automatically, exposing the sensor to the gas being tested and enabling accurate reading of moisture content in the sample gas. After each test the head assembly is closed by depressing the inner section so that the sensor will again be dried by the desiccant, leaving the sensor ready for use time and time again. The desiccant is kept in the inner chamber and is not exposed to ambient room air or the sample gas, therefore there is no need for frequent regeneration or replacement of the desiccant.

  • Vehicle Actuator Tester

    7651 - Peaceful Thriving Enterprise Co Ltd

    This device is design to test electronic components actuate by magnetic field or electronic magnetic field. Devices like actuator, ignition coil, AC generator, indoor air blower, valve controller EGR (exhaust gas control), injector, spark plug, relay and hall effect sensor can be tested.

  • Trace Nitrogen Analyzer

    Model 2120XL​​​ - Teledyne Analytical Instruments

    ​In many argon or helium gas supply systems, the detection of trace nitrogen (N2) is essential in determining system integrity. The Model 2120XL is the new standard in this critical measurement. It provides continuous and accurate nitrogen analysis using field-proven emission spectroscopic technology in a space-saving 19” rack-mount 3U package.

Get Help