Showing results: 331 - 345 of 1389 items found.
-
-
Test Products International, Inc.
No combustible gas equipment installation or service work should be performed without testing for leaks. Check all pipes, fittings, and valves for gas leaks, if any leaks are found repair or replacement should be performed.
-
Bestone Industrial Ltd.
Adopts the high quality and high performance catalytic combustion sensor with high sensitivity, good reliability, fast response and high stability. The instrument is widely used in urban gas.Department of petroleum,petrochemical,oil depots and gas stations and oil gas transmission and distribution pipeline safety inspection and pipeline maintenance and leakage and rescue etc.,gas industry essential leak detection equipment.
-
CI2000-RQD -
Shanghai ChangAi Electronic Science & Technology Co.,Ltd
Determining gas concentrations by measuring the thermal conductivity of the gas, CI2000-RQD analyzer uses advanced thermal conductivity sensor with single chip technology. It adopts platinum thread as sense organ to make up Imbalance Bridge, which output signal has a relationship with tested gas volume. And the single chip will magnify, sieve wavelength, modify linearly and criteria the signal by electric procedure.
-
JH4000SF-1 -
Xiamen Jiahua Electrical Technology Co.,Ltd
SF6 gas moisture is not only a major item for gas quality acceptance but also a key index to evaluate installation, maintenance and operation of SF6 electrical equipments. In IEC60480-2004 Guidelines for the checking and treatment of sulfur hexafluoride (SF6) take from electrical equipment and specification for its re-use, moisture is listed as a detection item for SF6 fresh gas, equipment acceptance, preventive test and maintenance.
-
Agilent Technologies
Agilent has led innovation and performance in gas chromatography/mass spectrometry (GC/MS) for over 40 years, from the first Agilent benchtop GC/MS through to the MS/MS-capable GC/Q-TOF dedicated to gas chromatography.The Agilent gas chromatography/mass spectrometry family of instruments and accessories provides the efficiency, flexibility, and robust performance that modern analytical laboratories require. Advances in ion source technology further enhance GC/MS robustness, and GC/MS libraries and analyzers allow you to quickly set up a gas chromatography/mass spectrometry method for simplified startup of specific applications.
-
SCA -
Bacharach, Inc.
The Neutronics Model SCA Single-Channel Gas Detector Control Unit is a wall mounted monitoring and control unit designed for installation in a safe area where there is no risk of the presence of potentially explosive gases. It can be used with the following detector configurations:*Fitted with an integral CO2 (IR), oxygen or toxic gas sensor for safe area use only*Connected to a remote CO2 (IR), oxygen, or toxic gas detector head for safe area use only*Fitted with an internal (or external) safety barrier and connected to a remote certified intrinsically safe (Ex ia) flammable, oxygen, or toxic gas detector head located in a hazardous area*Connected to a remote flameproof (Ex d) certified flammable, oxygen, or toxic gas detector head located in a hazardous area.
-
Ion Science, Ltd.
Semi Portable Gas Detectors and Leak Detectors meet the diverse requirements for gas detection industries throughout the world. Our range offers an ideal solution where a temporary detection or contractual detection is required for a specific project or incident.
-
UNION INSTRUMENTS
Natural gases and hydrogen are by nature low in odor or even odorless to humans. In order for potential leaks to be noticed and eliminated in a timely manner thanks to someone smelling the typical gas odor, these gases are supplemented with an odorant (i.e. odorized) in the gas grid.
-
SMC 20X/200X -
MSA
The SMC 20X/200X are single-gas detectors used to monitor combustible gas, hydrogen sulfide (H2S) or carbon monoxide (CO). The detectors are based on solid-state technology, a simple and robust method of detection capable of detecting low parts-per-million (ppm) levels of gas.
-
Weshine Electric Manufacturing Co., Ltd
In operation and during electrical failures, pollutants are generated which, depending on its concentration, reactivity and toxicity, modify the characteristics of gas for insulation and arc extinguishing. This may affect the safety of the installation and people. Gas handling operations can also cause the incorporation of pollutants.
-
Eco Bump -
Teledyne Gas & Flame Detection
Importantly, bump testing is the only way to validate that gas detectors will respond to gas and trigger user alarms.Simplified configuration (no software).Measuring only 7.2” (180mm) in height (including the push button regulator), the pocket-sized EcoBump can easily be stored and transported with minimal shipping costs.With 5.5L of bump gas capacity, EcoBump provides approx. 250 bump tests from a single cylinder making it our most cost effective bump solution.
-
CSM Products, Inc.
Reliable and precise acquisition of exhaust values: For exhaust gas measurements, i.e. Lambda, O2, NOx, and NH3 in vehicles with petrol, diesel, CNG or LPG engines CSM has expanded its product portfolio with the CAN-based exhaust gas measurement modules from ECM.
-
KM 5410 -
Kusam Electrical Industries Limited
* Hand-pump with filter to isolate dirt and particles.* Thermocouple offset adjustment ±3°C (6°F).* Automatic power off battery saver.* 2 channel display(LCD).* Display Back-Light.* Analyzer Directly Measures: Flue Gas Oxygen Content in % and Flue Gas Temperature in °F or °C* Analyzer Computes: When the measured oxygen level is below 17.9%, Flue Gas Carbon Dioxide content in %, , Excess Air in %(0 to 400%), Flue Natural Gas/Oil #2/Propane in %
-
iNet® Control -
Industrial Scientific
iNet® Control is gas detection management software that provides unparalleled visibility into your gas detection program. Now you can easily manage your hazards, people, and equipment from anywhere with one simple dashboard. For DSXi Docking Station customers, access to iNet Control is included at no additional charge.