Filter Results By:

Products

Applications

Manufacturers

Gas

1) fills any space it's contained in and is amorphous. 2) liquid fuel powering vehicles.

See Also: Dissolved Gas, Gasoline, Ammonia


Showing results: 481 - 495 of 1390 items found.

  • Air Quality / Gas / Flow Sensors

    Panasonic Industrial Devices Sales Company of America

    Panasonic offers compact, high sensitivity Air Quality, Gas and Flow Sensors for use in equipment or automation processes. Designed for air quality / IAQ monitors and home appliances, the Laser Type PM (Particulate Matter) Sensor can detect dust particles down to the 0.3 m size.

  • Toxic, Oxygen and Flammable Gas Detectors

    Process Sensing Technologies

    We can offer a wide range of flammable gas detection instruments for hazardous areas applications that measure hydrocarbon gases at the %LEL and %vol levels. Product options include explosion-proof and intrinsically-safe designs and the product offering includes technology options for both non-dispersive infrared and catalytic bead sensing methods.

  • Gas Filter Correlation CO Analyzer

    Model T300 - Teledyne Advanced Pollution Instrumentation

    DescriptionFeaturesSpecificationsApplicationsDownloadsMaintenanceThe Model T300 measures low ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 14 meters. The energy loss through the sample cell is compared with the span reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing extreme sensitivity.

  • Gas Filter Correlation CO2 Analyzer

    ​Model N360 - Teledyne Advanced Pollution Instrumentation

    The Model N360 measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the eff​ects of ambient CO2, if necessary.

  • ​Trace Level Portable Gas Calibrator

    Model T750U - Teledyne Advanced Pollution Instrumentation

    The Model T750U is a portable, microprocessor based calibrator for precision trace-level gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero calibrations. The T750U is housed in a high-density, molded travel case which includes an integral handle and wheels for durability and ease of use in the field.

  • Mechanical Oil / Gas Testing Kit

    Bacharach, Inc.

    The Bacharach Mechanical Oil / Gas Testing Kit is a complete kit that has HVAC technicians and contractors in mind. They include everything needed to perform a comprehensive combustion test, including the Fyrite® Classic (0-20% CO2), Draftrite® draft gauge, True Spot® smoke tester, fire efficiency finder and a Tempoint® thermometer in a carrying case.

  • Gas Calibrators and Zero Air Generators

    Teledyne Advanced Pollution Instrumentation

    All T Series instruments offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. Teledyne API offers an extensive line of high quality gas calibrators and zero air generators to meet even the most demanding applications.

  • Residual Gas Analyzers, Mass Spectrometers

    INFICON Holding AG

    the market-leading Residual Gas Analyzer (RGA) process monitoring system in the semiconductor industry for over a decade. Now Transpector CPM 3 provides industry leading measurement speed and sensitivity through a field proven pumping and inlet system integrated with a new sensor and electronics. Transpector CPM 3 is the ideal RGA process monitor for new and established semiconductor processes such as ALD, CVD, PVD, and Etch.

  • FTIR Motor Exhaust Gas Analyzer

    MEXA-ONE-FT - HORIBA, Ltd.

    The MEXA-ONE-FT Series simultaneously measures concentrations of multiple components, including NH3, N2O, CH4, CO and CO2, in undiluted exhaust gas using the Fourier transform infrared (FTIR) method in combination with a multivariate analysis algorithm. It incorporates HORIBA's proprietary compact interferometer which yields superior performance and high accuracy.The system complies with NH3 testing requirements of Euro VI, the EU regulation for heavy duty emissions testing.The MEXA-ONE-FT can be calibrated according to customer requirements with up to 6 component sets to cover a wide range of applications.FTIR spectroscopy allows the direct measurement of NO2 emissions and the independent quantification of individual hydrocarbon species. This makes the MEXA-ONE-FT system an ideal solution for detailed research and development tasks.Due to the measurement principle, the time-consuming daily span gas calibration is omitted.In addition, usability and flexibility are realized by “HORIBA ONE PLATFORM” which enables to extend the system with other ONE analyzers to a complete solution suitable for both certification and R&D purposes.

  • Hydrogen Peroxide Gas Concentration Analyzer

    PI2114 - Picarro Inc.

    The Picarro PI2114 gas concentration analyzer measures hydrogen peroxide levels as low as 4 ppb to help avoid oxidation and safeguard drug stability. Major pharmaceutical, CMO, and isolator companies use Picarro hydrogen peroxide analyzers in high-potency API and biologics manufacturing and in aseptic fill and finish. The PI2114 analyzer is fast and easy to use. It doesn’t need chemicals or consumables. And it requires infrequent calibration and maintenance to minimize operating costs.

  • MPS™ Refrigerant Gas Sensor

    NevadaNanotech Systems, Inc.

    NevadaNano’s Molecular Property Spectrometer™ (MPS™) MPS Refrigerant Gas Sensor provide accurate and reliable detection of mildly flammable (A2L) R-32, R-454b blends, R-1234yf and other low global warming refrigerant gases such as  (A1) R744 as well as (A3) R290 and R600 common in HVAC applications. With a 15+ year calibration interval and lifetime, the MPS A2L Refrigerant Sensors deliver industry-leading performance and the lowest total cost of ownership.

  • Low Power Wireless Gas Detector

    CX - Teledyne Gas & Flame Detection

    Model CX sensors are equipped with standard analog 4-20mA, and Modbus™ RTU RS-485 outputs and can be used with SmartWireless Site Sentinel CX/CXT controllers. The CX is a very low power device making it an ideal choice for a battery powered detector (optional) in applications where power is unavailable or not economically feasible.CX gas detection sensors are easily and economically deployable in both permanent and temporary installations. These low power sensor assemblies utilize electrochemical technology for a long list of toxic gases.​​​​​​​​​​​​​​​​​​​​

  • Fire, Gas & Intruder Controllers & Alarms

    MultiSafe-MX - Teledyne Gas & Flame Detection

    The MultiSafe-MX system is intended for the protection of high hazard, high risk plant and facilities.The MultiSafe-MX is certified, by European laboratories, to comply with the applicable regulations.The panel is composed of dedicated cards, installed in 19” racks which have their own “intelligence”, programmed for active/passive fire protection, gas detection, intruder alarm and logic functions. Moreover, the MultiSafe-MX can interact with supervisory and SCADA systems via Ethernet, TCP/IP or Modbus.The MultiSafe-MX interfaces with devices using either conventional and/or addressable module inputs and outputs. These modules are used to tailor the system to customer requirements.

  • Gas Detector — Methane, Butane, Propane

    ENVIROMUX-GD-MBP - Network Technologies Inc

    Use to detect leaks of combustible gas (methane, propane, butane, acetylene, etc.). Choose between two levels of detection. First level: Detects methane at concentrations in excess of 0.5%; Detects propane/iso-butane at concentrations in excess of 0.3%. Second level: Detects methane at concentrations in excess of 0.8%; Detects propane/iso-butane at concentrations in excess of 0.5%. Continuous air monitoring. Audible alarm signal: 94 dB at 1 foot. Relay specifications: level selectable, normally open or normally closed, 250V AC, max 5A. Maximum cable length: 1000 ft (305m). Powered by ENVIROMUX-2D/5D/16D. Regulatory approvals: CE.

  • Open Path Combustible Gas Detector

    SafEye (Quasar 900) - Teledyne Gas & Flame Detection

    The Open Path Combustible system detects hydrocarbon gases by analyzing the absorption of radiation caused by gases in the atmosphere and comparing it to background atmospheric absorption. This is accomplished between a pair of units: a Flash Source and a Detector that can monitor a distance of up to 200 meters.Open Path Combustible Gas Detectors are robustly designed and can handle the toughest environments: 316L stainless steel housings that meet IP66/IP68 and NEMA 250 6P egress standards; circuit boards epoxy coated for protection; MIL-C-810C testing for humidity, salt, fog, vibration, mechanical shock and temperature extremes; and SIL-2 approval per IEC61508 is a final statement in reliability.