Showing results: 496 - 510 of 1390 items found.
-
GCIS -
Kratos Analytical Ltd
The Kratos Ar Gas Cluster Ion Source (GCIS) is optimised for depth profiling organic materials in Arn+ cluster mode and inorganic materials in Ar+ monomer mode, dependent on the operating parameters defined by the user and the type of material to be profiled. In Arn+ ion cluster mode the ions can be accelerated up to a maximum of 20 keV. This enables the successful sputter depth profiling of the widest range of polymer materials to be undertaken. However, Arn+ cluster depth profiling has been shown to give very low sputter yields for inorganic materials. In order to retain the capability of generating depth profiles from this class of materials this ion source can also be operated in the more conventional Ar monomer (Ar+) mode.
-
Model T300U -
Teledyne Advanced Pollution Instrumentation
The Model T300U Trace-level CO analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. Using IR absorption with a Gas Filter Correlation Wheel, the T300U is designed to allow ultra-sensitive CO measurements while still meeting the requirements for use as a US EPA compliance analyzer.The optical bench is enclosed in a temperature controlled oven, dramatically decreasing instrument noise and drift. The objective and field mirrors in the sample cell are gold plated to maximize signal to noise performance, while a temperature-controlled Nafion dryer on the inlet minimizes water interference caused by ambient humidity changes. Periodically, the T300U seamlessly corrects its baseline by routing the sample through a heated catalytic CO scrubber. This Auto Reference function corrects zero drift and reduces the effect of interferences.
-
YDQW-50KVA/250KV -
Wuhan Sangao Electrical Test Installations Limit Co.
SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test, and for testing all GIS switchgears and GIS components such as insulators, insulating tension pole, GIS voltage transformer and so on, the PD test can be performed under the general environment because of the merits of encapsulation, the PD level of our equipment can be lee than 3pC, and it can be added a HV bushing to perform the withstand voltage test at the same time.Small and compact dimensions resulting in minimum space requirements. Light-wight components. Rugged construction to withstand long transportation stresses. Direct flanging to the test object. High safety for tester because of encapsulation of all HV parts. Large range of application in conjunction with HV bushing for withstand voltage test. Built-in HV measuring capacitor and coupling capacitor. Built-in HV disconnecting switch to separate multipath test object connector to ensure the safety of HV testing.
-
GC2010R -
Chongqing Kailian Yongrun Industrial Co.,Ltd.
GC2010R pure argon analyzer performs trace analysis on H2, O2, N2, total carbon (CH4, CO, CO2) in pure argon. It is equiped with FID, TCD, methane converter, ten-way injection valve, special chromatographic column. The whole analysis is completed through one injection with ten-way injection valve.
-
GC2010B -
Chongqing Kailian Yongrun Industrial Co.,Ltd.
To analyze trace hydrocarbon (C1 – C4) in liquid oxygen, liquid air, air at exhaust inlet of air separation equipment, and trace hydrocarbon (C1 – C4) in liquid oxygen tank. Provide data for safety production of oxygen generator and guide the production.
-
ViTec Co. Ltd
Virtual simulator models are developed using the LabVIEW programming environment. Virtual devices are made in the graphic editor Adobe Illustrator and imported into the LabVIEW environment. Display control panels-simulators reflect the controls and control of the real main (15 displays) and backup (9 displays) consoles.
-
iso DUAL INLET -
Elementar Analysensysteme GmbH
Dual inlet technology is the most precise, accurate and sensitive technique for carbonate and water analysis. Because of this, the iso DUAL INLET has a unique role in the paleoclimate applications where instrumental precision contributes directly to the precision of paleoclimate models. Whilst the world's climate continues to behave erratically, we must know what has happened in Earth's history before we can attempt to predict what will happen in the future. To elucidate this complicated story, the iso DUAL INLET is a valuable tool for paleoclimatologists to build a detailed picture of the past to better inform policy makers who might just be able to influence the future of our planet.
-
Model - KM CO-910 -
Kusam Electrical Industries Limited
KM-CO-910 Carbon Monoxide meter detects the presence of Carbon Monoxide (CO) & measures concentrations between 1-1000 parts per million(PPM). The meter indicates the presence of CO by a reading on the LCD & a beeper tone. The beeper function much like clicking of a geiger counter: above 200PPM, the beeper sounds continuously with the concentration of CO; from 35PPM to 200PPM, the beeper sounds discontinuously with the concentration of CO.
-
-
TRANSFIX -
GE Digital Energy
The TRANSFIX is an 8-gas on-line transformer DGA monitoring unit. Using specially developed advanced photo-acoustic detection technology, the TRANSFIX measures all significant fault gases (in ppm) as outlined by international standards as well as moisture in oil (%RH & ppm). The measurement of these gases allows the user to detect and diagnose a complete range of transformer faults.
-
SGA-1000 -
Atom Instrument
The ATOM SGA-1000 is an online process analyzer utilizing patented Excimer UV Fluorescence (EUVF) Technology to measure Total Sulfur in a variety of refinery process applications.ATOM Instrument offers the most versatile total sulfur analyzers available. The ATOM SGA-1000 has the fastest analysis time of any commercially available analyzer allowing user-defined, multiple cycle averaging to improve analyzer performance. The analyzer operating software is both intuitive and user-friendly. In addition, the ATOM SGA -1000 only requires bottled air for normal operation and does not require installation in a shelter.
-
(iGC-SEA) -
Surface Measurement Systems
The iGC-SEA is a second generation iGC instrument. It is the world’s only commercial instrument based on the iGC principle. The unique SMS injection scheme provides a wide range of injection concentrations with unrivalled accuracy and reproducibility.
-
MEXA-1170SX -
HORIBA, Ltd.
The MEXA 1170 SX is a new instrument used to measure sulfur for after treatment and transient lubricant oil consumption. The analyzer uses ultraviolet fluorescence (UVF) for detection and it can be operated in a total sulfur mode, analyzing sulfur oxides, hydrogen sulfide and all organic sulfur compounds. An inorganic sulfur mode will analyze hydrogen sulfide and the sulfur oxides. The final operational mode will analyze just the sulfur oxides. Any one of these modes can be selected by the user from a front panel interface.
-
C160 -
UEi Test & Measurement Instruments
Backed by UEi Service+ to give up to 6 years’ warranty, next day recertification, and a reduced cost of ownership. The C160 Residential Combustion Analyzer is instrument only, easy to use with a rugged design, multiple sensor protections and altitude compensation. Essential information for installing and maintaining furnaces and boilers all in one device.
-