Filter Results By:

Products

Applications

Manufacturers

Showing results: 5311 - 5325 of 5362 items found.

  • Vacuum Sensor, Thermocouple Vacuum Gauge for Roug​​h Vacuum

    DV-4 Series - Teledyne Hastings Instruments

    ​T​eledyne Hastings, manufacturer of the original DV-4, DV-5, and DV-6 thermocouple vacuum gauge tubes, produces vacuum measurement equipment with exceptional stability, accuracy, and reliability under the most demanding conditions.The Teledyne Hastings’ DV-4 Series thermocouple vacuum gauge tube/sensor can be paired with a variety of meters or controllers in the DV series to provide reliable, cost effective measurements in a variety of applications. The robust, easy to install gauge system translates a thermoelectric voltage to a vacuum pressure based on the density of the gas. The thermocouple gauge tube/sensor, DV-4, is fully compensated for temperature and rate of temperature change with no suspended weld to an external heater.The gauges are calibrated for nitrogen or air, but conversion factors for other gases are available from the factory. The thermocouple gauge or controller does not require recalibration when thermocouple gauge tubes are replaced further decreasing process down time. However, our DB-16D reference tube is available to confirm meter/controller performance. Installation accessories are also available from the factory to support your installation needs. One less thing to worry about, when performance matters! ​With a wide range of meter, fitting, relay and output options, the DV-4 Series can support a variety of applications.

  • Motor Testing Equipment for EOL- BLDC (Brushless) Motors

    MotorLine® - MLI-B - MOTOMEA

    *Performs QA testing on 100% of production without compromising line throughput (up to 10 motors per minute), reducing costs of defective products.*Determines acceptability to user predefined PASS/FAIL limits on production lines.*Provides motor performance data, from stall up to no-load, within seconds, including: torque, speed, current, voltage, input power, output power, time, motor efficiency, driver efficiency, direction of rotation.*Provides dynamic performance tests data, including: speed and torque spectrum, speed and torque oscillations, friction torque, friction spectrum, friction output power, cogging torque level.*Supports non-contact frictionless sensors.*Supports motor’s internal speed sensors.*Support sensorless BLDC motors.*Speed range up to 250,000 rpm.*Motor power switching is done by the motor electronics; the data sampling is started while the motor starts moving.*Motors can be tested inside their applications.*Motor performance data can be recorded in the system database for comparison and statistical analysis.*Test results are provided graphically and tabulated.*Test reports in PDF and Excel format.*Capability for integration with third party devices, such as hipot & insulation resistance testers.

  • High Voltage Isolation Switch Contact Pressure Tester

    WA1401 - Wuhan Sangao Electrical Test Installations Limit Co.

    Isolation switch is the high voltage switch equipment, it was large and frequently use in power system . The outdoor isolating switch is the only completely exposed in the atmospheric environment electrical equipment, It is also a electrical equipment affected by climatic conditions influence the most direct and most serious. The operating conditions is relatively poor, It is easy to generate fault of mechanical or electrical. Especially the finger contact part is easy to be affected by rain, dust and harmful gas invasion, resulting in poor contact caused fever, provide the spring with contact pressure due to heating and annealing for reducing the pressure, so that more cause finger heat form vicious spiral eventually burn out finger accident. In maintenance often only pay attention to replace the obvious failure and fracture of spring, but spring to reduce the pressure can not judge and replacement, so again in the operation, each finger current distribution by the pressure difference, The greater the difference between the current distribution is not uniform, long-term operation will occur is bad and the overheating. Fever finger will be vicious spiral, a finger contact bad will spread over the entire bad contact. At the same time, there are a lot of isolating switch contact pressure can be adjusted, if in maintenance adjustment pressure is not enough or each finger to adjust the pressure difference will also appear afore-mentioned phenomena.

  • Single-Phase Transformer Winding Resistance Meters

    RMO-TW Series - IBEKO Power AB

    RMO-TW series is perfect for winding resistance measurements of inductive objects. It is ideal for testing transformer windings (power transformers, distribution, autotransformers) and for on-load tap changer verification. In addition, any RMO-TW transformer ohmmeter & tap changer analyzer can also perform transformer demagnetization.The series contains 4 models, with maximal test currents from 10 A (RMO10TW) to 50 A (RMO50TW). They are fitted in a portable and lightweight metal housing.All transformer ohmmeters from RMO-TW series generate a true DC ripple-free current with automatically regulated measurement and discharging circuit. The injection of current and discharge of energy from the test object are automatically regulated.Three independent channels enable testing of three windings in series. Consequently, this enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.DV-Win software enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test. Finally, a user can export all results in the form of a report.

  • Coil Analyzers & Power Supplies

    IBEKO Power AB

    Coil analyzers and power supply units are portable and lightweight devices intended for use in harsh switchyard and industrial environments. The typical application is switchgear and circuit breaker testing when substation battery is not connected or available. An advantage over substation battery is enabled testing in under-voltage and over-voltage conditions. Furthermore, the stable voltage outputs with a very low ripple (<0,5%) enable an analysis of the coil and motor current graphs recorded with circuit breaker analyzers from different vendors.SAT40AD, POB30AD, and POB40AD are unique devices in the market due to their dual purpose:Power supply for coils and spring-charging motorsTesting circuit breaker’s coils, motor, and auxiliary circuitAll DV Power coil analyzers and power supply units have four separate outputs for opening and closing coils.SAT40AD has two powerful motor outputs (AC and DC) which can withstand up to 40 A inrush current.POB30AD and POB40AD have DC motor output rated up to 30 A and 40 A respectively. With the use of motor outputs, POB and SAT can also be used as a power source or a temporary battery charger.SAT40A II series instruments can be controlled via PC. The DV-Win application software is used to control both SAT and CAT (Circuit Breaker Analyzers & Timers) devices at the same time, making a unique test system for switchgear and circuit breaker testing.

  • Handheld Water Quality Meters

    LAQUA PC210 - HORIBA, Ltd.

    - Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display- ORP calibration option- Automatic / manual temperature compensation and temperature calibration function- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater - Auto log data; built-in memory can store up to 500 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached - Monochrome LCD with white LED backlight: 50 x 50 mm- Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty

  • Handheld Water Quality Meters

    LAQUA PD220 - HORIBA, Ltd.

    - Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display - Automatic / manual temperature compensation and temperature calibration function- ORP calibration option- Dissolved oxygen (DO) concentration in ppm (mg/L) and % saturation- 0.01 mg/L or 0.1% DO resolution- Compensates salinity, temperature, and atmospheric pressure - Up to 2 DO calibration points - With real-time clock and date/time stamp for GLP compliance- Auto log data; built-in memory can store up to 1000 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached- Monochrome LCD with white LED backlight: 50 x 50 mm- Phono jack output for connecting the meter to computer via PC (USB) cable for data collection and to printer via printer (RS232) cable for printout - Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty

  • LightRanger 4 Click

    64206 - Parallax Inc.

    Parallax speeds the process of Propeller 2 development through our partnership with MikroE, who has created a family of 850+ Clicks for most I/O functions you may envision. For each of the Click boards stocked by Parallax, you will find a documented Spin 2 code example on our Propeller GitHub Object Exchange. Connect your Click boards to the Propeller 2 Evaluation Board or P2-EC Edge Breakout Breadboard using the #64008 P2 to MikroBus Click Adapter. Light Ranger 4 click is an accurate distance measurement Click board™ based on a ToF (Time of Flight) measurement principle. The FlightSense™ enabled VL53L1X rangefinder module from STMicroelectronics is a complete measurement stack on the chip. It is surprisingly easy to work with, as this highly integrated range finder module exposes only I2C interface, XSH and INT pins to the host controller. It features the invisible Class1 laser emitter, used to emit a narrow band of a harmless modulated light beam in the IR range (940 nm), physical infrared filters and optics to achieve the best ranging performance in various ambient lighting conditions with a range of cover window options. It can measure distances up to 4000mm, with up to 50 Hz ranging frequency.

  • Interface for the Multimode, multiprotocol Excalibur 8000 Family of Carrier Boards, Providing a Complete Solution for Developing & Testing MIL-STD-1760 Interfaces

    M8K1760Px(S) - Excalibur Systems, Inc.

    The M8K1760Px(S) interface module for the multimode, multiprotocol, Excalibur 8000 family of carrier boards provide a complete solution for developing and testing MIL-STD-1760 interfaces and performing system simulation of the MIL-STD-1760 bus. The module handles all standard variations of the MIL-STD-1760 protocol.Each M8K1553Px-1760 multi function module contains 64K bytes of dual-port RAM for Data blocks, Control registers, and Look-up Tables. All Data blocks and Control registers are memory mapped, and may be accessed in real time. Each of the independent dual redundant M8K1760Px modules may be programmed to operate in one of three modes of operation: Remote Terminal, Bus Controller/Concurrent-RT, and Bus Monitor. In addition, modules 1 and 3 can be programmed to operate as Concurrent monitors, to modules 0 and 2 respectively.In addition, Checksum, SRQ bit and Header Words are supported on each channel, as well as, error injection (BC and RT modes) and error detection (all modes).Each M8K1760PxS single function module operates either as a Bus Controller, Remote Terminal, or Bus Monitor.The M8K1760Px(S) comes complete with Windows software, a C-driver software library including source code and may be used with Exalt, Excalibur’s Analysis and Laboratory Tools, a Windows monitoring application

  • vibration test system

    Labtone Test Equipment Co., LTD

    Labtone EV series of electrodynamic shaker vibration test System simulate the vibration environment under the laboratory condition, and test the impact strength as well as reliability of various vibration test applications.Labtone EV series of electromagnetic vibration testing system simulate the vibration environment under the laboratory condition, and test the impact strength as well as reliability of various vibration test applications. In the laboratory, with the aid of vibration testing system, simulations of reproduction of sinusoidal, random, resonant search and dwell, classical shock and road models, etc. can be achieved. It is essential for product quality assurance, new product research and development.Labtone EV series of electromagnetic vibration testing system is specially designed to meet the need for long time operation. Vertical and horizontal vibrations can be achieved by the installation of vibration resistant base. The standard platform is equipped with high efficiency airbag shock isolation device, so that the vibration transmitted to the building can be minimized. There is no need for additional foundation in most of the cases.A complete set of vibration testing system is composed of shaker, power amplifier and vibration measuring control system, in accordance with the relevant national and international standards (such as: MIL-STD, DIN, ISO, ASTM, IEC, ISTA, GB, GJB, JIS, BS, etc.) to provide technical support for establishing product quality inspection.

  • High Voltage Battery Test System

    9300 Series - NH Research, Inc.

    NH Research, Inc. (NHR) has released the new 9300 series, a higher-voltage / higher-power version of its popular single-channel 9210 series battery test systems. The 9210 Series provided a 12kW power module operating at 40V, 120V, or 600V and which allowed paralleling with similar systems to increase the power, whereas the new 9300 system provides a 100kW power module with a software-selectable high voltage range (1200VDC / 167A) and high-current range (600VDC / 333A) allowing for efficient testing of single-voltage and double-voltage Electric vehicle (EV) batteries as well as high-voltage Energy Storage Systems (ESS) used in grid-tied applications. The 9300 further extends NHR’s family of high-power battery test and emulation capabilities which are ideal for analyzing a battery performance under xEV drive cycles and grid-storage profiles such as PJM and time-shifting profiles. Like the successful 9200 and 9210 systems, the 9300 modules are independent allowing for testing of multiple batteries, each with a different test plan, power levels and start/stop times. When higher power is needed, the 9300 modules may be paralleled providing 200kW, 300kW or up to 1.2MW capability. This modular power capability allows a system to be sized to the power levels needed today while ensuring expansion capability should additional power be needed in the future.

  • Lithium battery 128kWh Lifepo4 Battery pack 280Ah with BMS for Solar Energy Storage System

    SPVLI-128kWh - Zhejiang Sandi Electric Co., Ltd

    ESS lithium battery system is composed of lithium battery modules, BMS system, PV charge controller, AC/DC Charger, central control unit CCU, temperature detector, integrated structure and other parts; the solar panels in the system are battery storage and power for output; BMS module completes the detection and control of voltage, current, temperature, SOC, SOH and charging and discharging related parameters of power battery pack; PV controller and inverter realize bidirectional AC/DC function to meet the charging and discharging conversion demand of power battery pack; each detector is used to monitor the ambient temperature in real time to ensure the safety of the system.1. Standardized components, modular architecture, easy for expansion2. High energy density, small footprint, short construction period, strong environmental adaptability3. Battery module within the layered stack design, with more than 10 years of long design life 4. Long Cycle Life LiFePO4 Lithium ion Battery system from 20KWH—500KWH optional5. The use of international advanced Mitsubishi IPM module and intelligent power module, with high power fast adjustment capability6. BMS battery management system with SOC automatic calibration and high current active balance function, combined with the perfect operation control and management strategies to achieve accurate and efficient management7. The combination of software and hardware protection, with alarm protection and automatic diagnostic functions, improve the protection strategy to ensure safe and efficient operation of the system8. Product communicates with the monitoring platform in real time through RS232, CAN communication interface, and reports various records in time to ensure real-time monitoring of the battery pack of the monitoring platform9. PV charge controller adopts three charging stages (buck charging, equalize charging and float charging) which can maximize the utilization of PV modules and batteries10. Colorful LCD display all module working information and statusPerformance characteristics:Small size and light weight, Maintenance-free;Environmental protection and pollution-free materials, no heavy;Accurately estimate the state of charge of the battery pack, that is, the remaining power of the battery, to ensure that the power of the battery pack is maintained within a reasonable range;Built-in BMS management system with comprehensive protection and monitoring control functions;5" LCD screen display, easy to operate, can check the temperature, voltage, working status, discharge current, dynamic and static SOC algorithm of a single cell, local display of alarm info, alarm level distinction, accurate positioning of abnormal cells;Main control MCU can be centrally controlled and manage peripheral settings (AC charging module, inverter module, solar charging module) to adjust the charging current and voltage of peripheral devices according to the battery charging curve, making the system more reliable;BMS battery management system, with SOC automatic calibration and high current passive balance function, combined with perfect operation control and management strategy, to achieve accurate and efficient management;EMS energy management system, BMS with solar controller/AC charger, inverter centrally manages charge and discharge, effectively controls the charge and discharge current within the cell usage conditions, protects the cell and extend its service life;SpecificationLithium battery 128kWh Lifepo4 Battery pack 280Ah with BMS for Solar Energy Storage SystemModel SPVLI-128KWHType of cell LiFePO4 (Lithium iron phosphate)Battery cell configuration 3.2V 280AH 144PCSRated capacity (KWH) 128kwhNominal capacity (AH) 280AHNominal voltage (VDC) 460VOperating voltage range (VDC) 375-540VRecommended Charge Voltage (VDC) 504VRecommended discharge cutoff voltage (VDC) 382VRecommended charge current(A) 140AMax Charge Current (A) 280ARecommended discharge current (A) 140AMax Discharge Current (A) 280ACharge temp range 1~45℃Discharge temp range -10~45℃MPPT Solar Charge Controller InputMaximum. Input voltage of solar array(Vdc) <900VdcBattery system voltage 460VDCMaximum power of solar array 64KWMaximum charge current(A) 140AEqualization charging voltage (Vdc) 511.2VEqualize charging recovery voltage (Vdc) 486.72VOver voltage disconnect voltage (Vdc) 525.6VOver voltage recovery (Vdc) 518.4VWorking temperature -20~50℃Protection level IP20Communication interface CAN2.0, BMSDisplay 5" LCD, EnglishCooling system Fan coolingWorking Altitude (m) ≤3000mReference Weight (Kg) 1530KgReference size (W*D*H mm) 1200*1120*1950mm

  • AC Fuel Flow Signal Generator

    TA-100 - Tech-Aid Products

    The TA-100 signal generator was designed to facilitate testing of aircraft fuel flow indicators that require two input signals designated as “Drum” and “Impeller”. This generator provides both signals so as to provide a direct interface to the fuel flow indicator under test. The generator also provides switched power out to the unit under test as well as a 5v source for testing the bezel lighting. The original design was built around the requirements for the AMETEK series indicators (pn: 10171 series). This generator simulates a reference and a time delayed signal of appropriate amplitude for an indication of up to 1200pph for the indicator under test. The “PPH Select” switch provides fixed signal delays representing 0, 200, 400, 800, 1000 and 1200pph flow rates respectively, this provides the mechanic with an expedient check of the indicators accuracy. The “PPH Adjust” control allows the mechanic to vary the signal delay throughout the full range and serves as a good method for checking of pointer smoothness from stop to stop. The unit’s front panel also provides test jacks to monitor the “FDR Output” as well as the drum and impeller signals. The TA-100 requires only 28Vdc to operate. This generator provides a very economical approach to any repair facility or flight department as it becomes an alternative to purchasing two bench top signal generators. The TA-100 generator at the very least can provide a simple functional test and eliminate the high cost of exchanging an indicator as a function of troubleshooting the aircraft system.

  • Circuit Breaker Test Equipment

    IBEKO Power AB

    DV Power has released a new generation of circuit breaker test equipment for condition assessment of medium and high voltage circuit breakers.Field-portable instruments with standalone or PC controlled functionality, allow performing various tests during circuit breaker manufacturing, commissioning and maintenance stages.Applications supported by the DV Power test equipment include measurements of:Contact resistanceDRM (dynamic resistance measurement)Coil resistance and coil current (IEC 62271-100)Mechanism charging time (IEC 62271-100)Minimum trip voltage (IEC 56, ANSI C37.09)Undervoltage release (IEC 60694)The timing of a circuit breaker’s main, auxiliary and pre-insertion contactsSynchronization between the contactsMotion and velocity“First trip” testThe essential part of a circuit breaker condition assessment is the ability to compare the latest test results with the previous testing. Accordingly, our instruments store measured values and compare them to a manufacturer’s limits. Also, a fingerprint obtained in this way can be used at a later stage as a reference during subsequent measurements. In order to obtain an accurate comparison, the tests need to be performed using identical test parameters. Consequently, any deviation and change in the test results may indicate the circuit breaker condition deterioration. Even more, to overcome this issue, DV-Win enables test plans and graph overlay features.Finally, as a final result of a circuit breaker maintenance process, the DV-Win provides analytical tools and customized report creations.

  • Digital Leakage Current Tester

    Educated Design & Development, Inc.

    Fast - All operator controls are located on the front panel to expedite testing. The entire test can be performed in a matter of seconds! Pays for itself in time and stress savings. Versatile - Measures Leakage Current in accordance with UL, CSA, EN, and IEC/ International Standards. Includes ability to perform open neutral, open ground, and line polarity forward/reverse test conditions. Adaptable - Universal rear panel receptacle allows for testing products with any plug configuration. Accurate - True RMS meter accurately measures both sinusoidal and non-sinusoidal waveshapes. This is important when testing products using a switch mode power supply which can generate non-sinusoidal leakage currents. Calibrated, traceable to NIST. Flexible - A front panel switch permits testing either through the power cord of the product under test, from surface/ patient connection-to-ground, or from surface/ patient connection-to-surface/ patient connection. Portable - Lightweight, with integral handle. Other Features - Product Ground Switching (grounding conductor maintained to device under test when not measuring leakage). Automatic front receptacle disconnect when configured in the 240V test mode (prevents inadvertent connection of 120V when configured for 240V operation). Proven - These are the only leakage current testers designed and supported by Product Safety experts. That is part of the reason why they have become the standard in the industry. Full technical support by experienced safety engineers.

Get Help