Filter Results By:

Products

Applications

Manufacturers

Showing results: 4051 - 4065 of 5324 items found.

  • Test System

    4003 TLP+™ - Barth Electronics, Inc

    The Model 4002 TLP+™ test system was the first turn-key commercial TLP developed for the ESD industry and has remained the leader in the ESD square pulse testing field since this method was first introduced in 1989. This tester is the ultimate design and analysis tool for ESD protection circuits. It provides Pulse Curve Traces of circuit characteristics which simulate ESD tests. This allows you to see into a chip’s operation taking out the guesswork which speeds your design and minimizes lost time.

  • DXN Portable Hybrid Ultrasonic Flow Meters

    Badger Meter

    The Dynasonics DXN meter is a powerful tool for troubleshooting flow issues, whether you want to quickly verify the flow reading of another meter or to data log flow system values over an extended time period. The DXN portable meter has transducers that clamp onto the outside of the pipeno tapping or cutting is required. The meter can be easily moved and installed in different locations. The large color display makes it easy to read and the setup wizard walks you through the meter configuration steps.

  • Battery Formation and Testing System

    BFS 2000 - BENNING Elektrotechnik und Elektronik GmbH

    For many decades now, BENNING has designed and manufactured charge/discharge converters for the battery industry. These converters are used in both the production and testing processes involved in battery manufacturing and for series-testing of batteries. BENNING's BFS battery production and testing system provides a solution which makes it easier to control and monitor production and test processes which saves both time and energy. When used in power stations and rail applications (mobile version), it can be used to test and maintain a wide range of battery types.

  • PXI 3A Power MUX BRIC, 18-Channel, 16-Pole

    40-571-206 - Pickering Interfaces Ltd.

    The 40-571 is a Power Multiplexer designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is possible for most configurations, see switching specifications for restrictions). It is ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. It is available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts.

  • PXI 3A Power MUX BRIC, 12-Channel, 16-Pole

    40-571-204 - Pickering Interfaces Ltd.

    The 40-571 is a Power Multiplexer designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is possible for most configurations, see switching specifications for restrictions). It is ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. It is available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts.

  • Pulsed and CW lasers, 375 – 1700 nm, 1 kHz measurement rate

    871 Series - Bristol Instruments, Inc.

    The 871 Laser Wavelength Meter from Bristol Instruments is the best way to measure the absolute wavelength of both pulsed and CW lasers and OPOs. By combining proven Fizeau etalon technology with automatic calibration, the reliable accuracy needed for the most meaningful experimental results is ensured. What’s more, a sustained measurement rate of 1 kHz enables the wavelength characterization of every single pulse for most lasers. And, the resulting time resolution of 1 ms provides the most detailed analysis of tunable lasers.

  • EasyView™ Indoor Air Quality Meter/Datalogger

    Extech EA80 - Extech Instruments Corporation

    The EA80 checks for Carbon Dioxide concentrations using a maintenance-free dual wave NDIR (non-dispersive infrared) CO2 sensor with a range of 0 to 6,000 PPM. It can automatically data log up to 20,000 data sets or you can manually enter up to 99 sets for later recall. Additional features include: auto power off, data hold, max/min with time stamp and alarm. Comes complete with six AAA batteries, Windows 95/98/NT/2000/ME/XP compatible software and an RS-232 interface cable.

  • Test System

    ITC57300 - Integrated Technology Corp.

    The ITC57300 Dynamic Parametric Test System mainframe accepts Test Heads that perform nondestructive transient measurements on semiconductor devices such as Insulated Gate Bipolar Transistors (IGBT), power MOSFETs, diodes, and other bipolar devices(requires additional optional bias power supplies and custom personality boards). Included in the mainframe are all test equipment and software necessary to analyze and perform resistive and inductive switching time, switching losses, gate charge, Trr/Qrr, and other transient tests.

  • Dual Channel Driver Card

    42460 - Pulse Instruments

    Two channels of 32 MHz clock drivers with up to 20 volt amplitude. The output voltage range is ±20 V, with independent high and low voltage settings. The inputs to the Card can be optically isolated. The card also contains voltage and current sense capability, which allows muxing of the current or voltage output measurements from all the Driver Channels in the system to a single DVM. The card allows independent programming of the rise and fall time of each channel one nanosecond increments.

  • Dual Channel Driver Card

    40461 - Pulse Instruments

    Two channels of 8 to 10 MHz drivers (25 V amplitude). The output voltage range is ±25V, with independent high and low voltage settings. The inputs to the Card are optically isolated. The card also contains voltage and current sense capability, which allows muxing of the current or voltage output measurements from all the Driver Channels in the system to a single DVM. The card allows independent programming of the rise and fall time of each channel as low as one nanosecond increments.

  • Electric Insulation Oil Automatic Measurement System

    DAC-5016 - Soken Electric Co. Ltd

    DAC-5016 is an automatic test system of insulation oils according to JIS C-2101.The system automatically enables changing over samples (liquid cells) up to max 8 pieces and testing the dielectric loss tangents and the volume resistivities.In automatic mode, the dielectric loss tangents and the volume resistivities are automatically measured, and then the results are printed out with the built-in printer. And the relative permittivities and the volume resistivities calculated are also printed out. Therefore the test time is greatly saved compared to the conventional test methods.

  • Stationary Circuit Breaker Test System

    ACTAS C160 - KoCoS Messtechnik AG

    Stationary test system for carrying out fully automatic final factory tests, type and function tests on all kinds of switchgear devices, such as circuit breakers, disconnectors or earthing switches, regardless of the type of drive unit. All the electrical and mechanical parameters needed for the assessment of switching performance are measured in real time and evaluated without either the main contact chambers or the drive unit having to be opened. The system has analog and incremental input channels for the acquisition of analog quantities.

  • NSOM & SNOM SPM

    Nanonics Imaging Ltd.

    NSOM Is the premier tool for imaging and manipulation of light on the nanoscale and is a critical instrument for understanding plasmonics, photonic waveguides, photovoltaic and photoconductivity studies. The optical openness of the NSOM system permits any illumination scenario while the Multiprobe NSOM head offers optical transport and dynamic study on the nanoscale for the first time. Offering a variety of options from entry level to low-temperature systems, the MultiView NSOM series has been the platform of choice for imaging on the nanoscale for nearly two decades.

  • FADEC/EEC Test Platform

    Bloomy Controls, Inc.

    The FADEC/EEC Test Platform provides a hardware in-the-loop (HIL) closed-loop test environment for dynamic and maintenance testing of full-authority digital engine control (FADEC) and electronic engine control (EEC) units of both rotary- and fixed-wing airframes. The system simulates one or more turbofan engines, including its sensors and actuators for use with the most sophisticated FADECs and EECs on the market. The system delivers repeatable, cost-effective testing in a fraction of the time needed with typical in-house simulation test systems.

  • Quasi Square Wave Constant Voltage Transformers

    Osborne Transformer Corp.

    Osborne Quasi Square Wave Constant Voltage Transformers are used to regulate output voltages for applications that have varying input voltages. When used with a rectifier conversion circuit, these units provide an elegant design approach to voltage regulation. Osborne achieves this innovative approach by partnering the constant voltage transformer with an auxiliary resonant capacitor winding. The result is a unique (though time honored) technology that offers reliability, performance, and cost advantages over other styles of voltage regulation.

Get Help