Filter Results By:

Products

Applications

Manufacturers

Gas

1) fills any space it's contained in and is amorphous. 2) liquid fuel powering vehicles.

See Also: Dissolved Gas, Gasoline, Ammonia


Showing results: 1321 - 1335 of 1395 items found.

  • Insulation & Multifunction Tester (LCD Display)

    4175 TMF - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Telecommunication test voltage : 50V and 100V.● Large range of insulation test voltages: 50, 100, 125, 250, 500, 1000V.● Mov / protection devices test.● Gas Arrester function.● Automatic voltmeter AC/DC at Start/Reset.● Test ON-OFF.● Battery test.● Safety voltmeter before each test.● Auto-discharge on all test and all ranges.● Battery test at Switch ON-TEST.● Smart hold & Stop on voltmeter AC/DC.● eads AUTO-NULL Key.● Test Auto-stop.● Auto range.● Ener-Save™.

  • HV Rotary Switches

    B-1003 - ROSS ENGINEERING CORPORATION

    A key feature of our rotary switches is their simple mechanical design which results in conservative stress levels for trouble-free, long life use.  In addition, each rotary switch has a reinforced chassis design utilizing G-10 or G-11 fire retardant anti-tracking coated epoxy glass insulation.  G-7 silicone glass is used for special applications where RF or high temperatures are involved.  Heavy duty contacts, specifically designed to minimize corona in the Ross rotaries, are made of highly conductive yet weld resistant alloy with high contact closing force.  This high force gives our rotary switches high momentary current capability and a reputation for their ability to withstand high shock and vibration as well as other severe environmental conditions.  Ratings to 150kV, to 200A.  When immersed in insulating oil, fluid or gas, the voltage withstand value is at least doubled and the interrupt capability is much greater.  In a gas atmosphere, no modification is required. However, immersion in oil or fluid may require modification in some cases, at an extra cost (optional).  Each unit is either manually or electrically operated.  One SPDT contact is standard on most units.  The auxiliary contact is used as an interlock for protection against "Switching Hot".

  • UNI-T Series

    Weshine Electric Manufacturing Co., Ltd

    mainly used to measure the wire resistance of cables, the contact resistance ofswitches, connectors, relays, the resistance of coils, motors, transformer windings, and equipment enclosures, lightning protection belts, ground beams, structures, cabinets, steel bars, Test the connection resistance between metal components of water pipes, windows, guardrails, radiators, assembly lines, etc. It is widely used in telecommunications, electric power, meteorology, computer rooms, oil fields, power distribution lines, tower transmission lines, gas stations, factory grounding grids, lightning rods, etc.

  • Constant Volume Sampler

    CVS-ONE - HORIBA, Ltd.

    The CVS-ONE series is designed for the measurement of diluted emissions from vehicles and engines. The new integrated operating platform, HORIBA ONE PLATFORM is adopted for the CVS-ONE. The hardware has been significantly downsized from previous designs, reducing test cell footprint requirements. It introduces new functions and is more user-friendly, while still maintaining high accuracy. In conjunction with the MEXA-ONE (Motor Exhaust Gas Analyzer), the system can be used to measure extremely low emission levels such as SULEV. The new CVS reliably supports emission testing requirements of today and into the future.

  • Leak Test Instrumentation

    Cincinnati Test Systems

    At Cincinnati Test Systems (CTS), we are dedicated to providing our customers with superior quality leak testing systems. With access to advanced designs, features, and test algorithms in our leak test devices, we promise a fast and reliable leak test product that will also provide repeatable results for air leakage testing, gas leakage testing, or any other leak where reliable testing equipment is needed. Browse our family of products to learn more on how our standard and custom built systems can meet your needs:

  • Custom Cable Assemblies

    Ametek Power Instruments

    AMETEK Power Instruments has designed and manufactured electrical, thermocouple, and fiber optic harness assemblies for more than sixty years. We have the experience and capability to produce rigid and flexible harness assemblies for virtually any application, whether it is a missile ignition assembly, aircraft actuator assembly or a thermocouple harness for an industrial gas turbine. AMETEK Cable & Harness Products boast superior reliability, high temperature operation, numerous braiding options for abrasion resistance and EMI shielding, waterproof or environmentally sealed, and custom molding. For more information, please contact us.

  • Flow Tester

    Mass Flow - ATEQ Corp.

    At ATEQ, we carry both touch screen and digital mass flow leak testers models. Our products have a simple setup and are easy to operate.Since flow testing is typically used for calibration and leak detection, it is important that you have a reliable, accurate, and user-friendly mass flow air product on hand. Common uses for our mass flow testers include discovering fluid and potential gas leaks, as well as occlusion testing. It is imperative that both objects you test with this type of instrument carry nearly identical reference volumes.

  • High Voltage Relays

    B-1001 - ROSS ENGINEERING CORPORATION

    Air insulated types for isolating loads, tap selections, safety discharge & grounding to help meet OSHA and other safety regulations. Ratings from 1mA to 800 amps continuous, to 100,000 amps capacitor discharge. Peak 1 minute test voltages from 5kV to 300kV. Single or Multipole. Auxiliary contacts are optional on all types. Options include latching, extended life, and tungsten contacts available for high current closing. DC, 25-800Hz & air pressure actuation available. Also usable in oil or insulating gas with increased ratings.

  • Compact Ultrafast 50-50,000 sccm Mass Flow Controller/Meter

    C-Series - MKS Instruments

    The C-Series Mass Flow Controller (MFC) is a compact, fast-response model using a Micro-Electro-Mechanical Systems (MEMS) based flow sensor for non-corrosive gas applications. It is available in Full Scale flow rates from 50 sccm to 50 slm (N2 equivalent) with a control range from as low as 0.1% of Full Scale up to 100% of Full Scale and is also available as a flow meter. Analog (0 to 5 VDC) or digital (RS485 or Modbus TCP/IP) communications interfaces are available. Required power supply voltage is 24 VDC nominal.

  • Valve Leak Measurement System

    VLMS - G Systems, l.p.

    The G Systems Valve Leak Measurement System (VLMS) reliably measures slow leaks that are unidentifiable with conventional leak detectors, helping manufacturers test and ensure that critical valves are absolutely airtight. The G Systems VLMS is a self-contained counting instrument for automating the industry-standard practice of leak detection by bubble formation using a submerged tube in water. The G Systems VLMS provides accurate measurement of leaks that are too small for conventional flow meters to reliably detect and is ideal for applications that must be absolutely airtight, including medical device, pharmaceutical, oil and gas, and plumbing valves.

  • BME680 Environmental Sensor

    28061 - Parallax Inc.

    Raise your project’s environmental awareness with the BME680. The Bosch Sensortec BME680 Integrated Environmental Unit combines a gas sensor with air pressure, humidity, and ambient air temperature sensing functions within a single package for high performance air quality measurement.  Parallax Inc. places the BME680 on a compact PCB with a 6-pin male header. This capable sensor does not have to be difficult to use. The BME680 is supported by BlocklyProp visual programming as well as C libraries for the Propeller multicore microcontroller.  Code for other controllers is available from the Bosch Github repository.

  • Carbon / Water Analyzer

    CW‑800 - ELTRA GmbH

    Determination of released carbon dioxide and water is a special requirement for quality control in the cement and lime industry. ELTRA’s CW-800 analyzer is designed for the precise, simultaneous determination of carbon dioxide and water in lime, gypsum and cement from trace level up to 100 % (depending on sample weight). Other sample materials include ores, soil and minerals. The CW-800 is equipped with a resistance furnace with quartz tube for sample oxidation and can provide temperatures up to 1000 °C. The temperature of the CW-800 can be set up in steps of 1 °C and the temperature is fixed during measurement. As common carrier gas in the CW-800 nitrogen is used.

  • PMS Leak Test System

    UNION INSTRUMENTS

    The system (Pressure Measuring System) is a portable, complete system for leak tests. This consist of the pressure test kit PMS3000 for performing leak tests with an integrated graphic-capable 4.3” color touch display and a pressure relief kit DAK2000 for discharge test according to W400-2, Part 16 pressure loss methods as well as DIN EN 805. The system is complemented by a variety of connection accessories like the rugged accessory case (individually equipped), the test standpipe PSR and accessories for building gas connection as well as the electronically controlled test pumps EPP and the compact air compressor KLK1030.

  • Total Sulfur Analyzer

    Model T108 - Teledyne Advanced Pollution Instrumentation

    The Model T108 Total Sulfur analyzer is designed to measure mixed sulfur impurities, collectively referred to as Total Sulfides, in air or carbon dioxide gas. Since there is no scrubber in the system, the instrument reading is the sum of the oxidized sulfur compounds and SO2.The Model T108 consists of a modified Model T100 SO2 analyzer with special software and a Model 501TS high temperature thermal oxidizer. Sulfur compounds are heated as they pass through the converter and oxidized into SO2. When analyzing CO2, which generally contains no oxygen, approximately 6% O2 is added to the sample before entering the converter. This dilution is corrected in the calibration procedure.

  • Ultrasonic Flow Meters

    WIKA Alexander Wiegand SE & Co. KG

    In-line ultrasonic flow meters provide accurate gas flow measurement by calculating the transit time difference ratios between ultrasonic paths into a pipe. WIKA ultrasonic flow meters are intrinsically safe (ATEX/IECEx) and approved for custody transfer (MID 2014/32/EU, OIML R137). These solutions ensure low power consumption and easy and quick installation and commissioning, and are suitable even in the most demanding applications. Sound velocity, signal-to-noise ratio and other additional measured variables are available for condition monitoring, as well as connectable pressure and temperature sensors for achieving integrated volume conversion.

Get Help