Showing results: 541 - 555 of 1389 items found.
-
Model T300 -
Teledyne Monitor Labs
The Model T300 measures low ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 14 meters. The energy loss through the sample cell is compared with the span reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing extreme sensitivity. All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information, is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T300 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
JH4000D-4 -
Xiamen Jiahua Electrical Technology Co.,Ltd
JH4000 series SF6 Electrical Equipment Gas Comprehensive Detector is a high precision, intelligent and portable comprehensive detector. It detects the main decomposition products, as well as SF6 purity and moisture content. It is reliable, accurate and stable. The user is able to make rapid and accurate judgment based on the content of main decomposition products, SF6 purity and moisture content. Inspected by authorities such as the National Institute of Metrology, the device, having excellent performance, complies with relevant international and national standards. It is a product recommended for use by the State Power Grid Company. This comprehensive detector is designed flexibly for the user’s choice. They can combine any two or three detection together. They can work simultaneously or separately, providing more complete measures for the inner fault diagnosis and it is an effective measure for preventive and corrective maintenance.
-
FSM -
CKD Corporation
Ultra-compact flow sensor for compressed air and nitrogen gas.Since it is lightweight and responds quickly, it is ideal for confirming the adsorption of electronic parts.
-
GCMS-TQ8040 NX -
Shimadzu Corp.
The Shimadzu triple-quad GCMS-TQ8040 NX features smart technologies to boost the efficiency of routine analytical work. For example, Smart MRM provides fully-automated MRM method development. It automatically determines all optimum transitions and collision energies, seamlessly incorporating them into the Smart Database Series. With features like this, the GCMS-TQ8040 NX GC-MS/MS is so smart it almost runs itself! Perfect for applications in fields such as environmental monitoring and food science.
-
DP-100 -
Panasonic Industrial Devices Sales Company of America
The DP-100 Dual Display Digital Pressure Sensor is a highly accurate and reliable Pressure Sensor that is equipped with a new visual display that features a wider viewing angle and improved clarity. The pressure and set range part of the display has also been increased as another improvement. The DP-100 Series also offers a multi-function type that enables the selection of analog output (voltage/current) or external input (auto-reference/remote zero-adjustment) to comply with a wide range of applications.
-
DP-100L -
Panasonic Industrial Devices Sales Company of America
Panasonic’s compact DP-100L Pressure Sensor with IO-Link features an improved digital display that offers increased clarity and a wider viewing angle. Thanks to a redesign of its circuitry, the low-power-consumption DP-100L Series requires 14% less power during normal operation and when operating in ECO / FULL mode the display is completely shut off for an increased power savings of up to 50% compared to normal operation. The current value and the threshold value can be checked at the same time, so the threshold value can be set and checked smoothly without switching to another screen mode.
-
-
775 -
Summit
16 inch Gooseneck. Range : 0 to 2000 ppm, Leak 8 Step Level. Functions : Recording ( MAX ), Both audibly and visually, Low battery indication, Elapse time
-
National Technical Systems
Any product or system component that’s exposed to the air has the potential to incur damage due to atmospheric conditions and contaminants. For telecommunications, aerospace, automotive and other equipment, these conditions can lead to premature wear and potential liability issues down the line. As a result, air testing equipment has become an important part of the quality-control process.
-
Nexis SCD-2030 -
Shimadzu Corp.
The Nexis SCD-2030 is a next-generation sulfur chemiluminescence detection system. It has been developed to fulfill the unmet needs of laboratories the world over. The dramatically enhanced sensitivity and reliability, the excellent maintainability, and the automation functions, a first for the industry, will improve laboratory productivity.
-
SA-9600 Series -
HORIBA, Ltd.
The surface area of a material is, in many cases, as important as the chemical properties. As particle size decreases, surface area increases. Porosity of materials - from micropores to macropores - contribute even more to the total surface area. The interface at the surface is what defines how a solid reacts to other substances, be they gases, liquids, or solids.Surface area can impact shelf life, stability, dissolution and efficacy of pharmaceutical powders and tablets. Likewise, surface area can affect the rheological properties and hiding powers of pigments, paints, and coatings. It has a significant impact on the ability for materials like catalysts, adsorbents, filtration materials and air separation products to react in the designed application. Ceramics used in applications ranging from; dinner plates, to dental implants, to electronics, all are affected by surface area.
-
GCMS-TQ8050 NX -
Shimadzu Corp.
The Shimadzu triple-quad GCMS-TQ8050 NX is capable of performing unprecedented quantitative GC-MS/MS analyses of ultra-trace amounts, down to the femtogram level. Equipped with a new, highly efficient detector and three forms of noise-reduction technologies, the GCMS-TQ8050 NX has never been more important in industries such as food safety, cannabis testing, forensics, and more.
-
410114133 -
Virginia Panel Corporation
The sloped enclosures come capable of having a Gas Spring accessory installed on the left, right or both sides of the enclosure. The enclosure comes standard with one Gas Spring accessory on the right side.
-
FLIR QL320 -
Teledyne FLIR
The QL320 is a quantitative optical gas imaging (QOGI) system that allows surveyors to measure the leak rates for methane and other hydrocarbons. This eliminates the need for secondary sampling with a toxic vapor analyzer or similar tool. In addition, the QL320 does not require close contact with the gas in order to measure emission rates, making it a safer solution for quantifying difficult-to-measure gas leaks.
-
MKS Instruments
The Precisive® Gas Analyzer is a real-time gas analyzer based on MKS' unique Tunable Filter Spectroscopy (TFS™) platform. The Precisive suite of products are calibrated for the measurement of a wide range of gases across multiple process industries. The real-time, continuous measurement capability provides immediate analysis ensuring control of critical process parameters.