Filter Results By:

Products

Applications

Manufacturers

Gas

1) fills any space it's contained in and is amorphous. 2) liquid fuel powering vehicles.

See Also: Dissolved Gas, Gasoline, Ammonia


Showing results: 1276 - 1290 of 1396 items found.

  • Lightning Surge Generator

    CDN-5809 - Shanghai Sanki Electronic Industries Co., Ltd.

    CDN-5809 signal line/data line coupling decoupling network, unshielded asymmetric communication line suitable for surge pulses and ringing wave pulses, designed according to Figure 9 of the new standard IEC61000-4-5.Ed3. It also satisfies vibration Figure 9 of the ring wave standard IEC61000-4-12Ed2 requires unshielded asymmetry. According to the characteristics of the line, the pulse coupling can be realized by gas discharge tube, capacitor, diode and other different methods.

  • Smaet LDV III

    KANOMAX USA, Inc.

    A Laser Doppler Velocimeter (LDV) measures fluid velocity by utilizing coherence of laser light. It detects the Doppler shift frequency of the scattering light of particles in the fluid and calculates the velocity of the particles (fluid). With a LDV system, non-intrusive measurements without disturbing the measuring object, liquid or gas flow, are achieved. No calibration is necessary and reverse flow measurements at a high resolution is also possible. The LDV system provides the absolute value of the flow velocity with accuracy.

  • Light Source

    pE-300white - CoolLED Ltd.

    CoolLED's pE-300white offers intense, broad-spectrum LED illumination for imaging most common fluorescent stains. The pE-300white Light Source can be fitted directly to the microscope or specified with a liquid light guide. The system is a mercury-free alternative that is safer, more controllable, and repeatable than conventional high-pressure gas discharge illuminators. Spectral coverage is from the UV (DAPI excitation) to the Red region (Cy5 excitation). The system is perfect for hospital and regular research laboratory environments.

  • High Density Plasma Etching System for 200mm substrates

    Model DRIE-1200-LL-ICP - TEK-VAC INDUSTRIES Inc.

    Single process chamber for high rate plasma etching of 200mm wafers. Loadlocked. Stainless steel construction. Capabilities of smaller, multiple wafer throughput. Substrate materials include (but are not limited to) silicon, silicon oxynitrides, SiC, SiGe, Aluminum, and III-V compounds including GaAs, GaN, GaP, and InP. Stable plasma generation capabilities to below 1 mTorr. Five, Six, or Eight gas mass flow controllers are standard. Expanded or reduced numbers are available upon request.

  • Flow Meter Calibration

    Smartech Inc.

    We offer a wide range of Flow Meter Calibration that is being used to measure linear, nonlinear, mass or volumetric flow rate of a liquid or a gas. Our ranges of products have the well-known features like durable dimensionally precise, longer service life, corrosion resistant and easy operation. These are provided with the calibration accessed for accurate measurement within the limits of its specification. These meter calibrations are widely appreciated for their high quality and they require less maintenance.

  • Chilled Mirror Hygrometers

    Process Insights, Inc.

    We are internationally recognized as a leading developer and manufacturer of the high-quality MBW Calibration chilled mirror dew point hygrometers used in a variety of humidity calibration, measurement and gas quality applications. Most notably, our MBW instruments provide the calibration traceability for many laboratories such as humidity instrument manufacturers and National Metrology Institutes. Our MBW chilled dew point mirrors continue to be chosen as transfer standards for inter-laboratory comparisons both regionally and internationally.

  • Meter Pulse Splitter

    SY027 - Synectic Electronics

    Our SY027 Pulse Splitter is designed to convert pulses from meters or other turbine devices and transmit the same pulse via two relay outputs to enable two separate instruments to measure the rate simultaneously. It can be used with either electricity, water or gas meters (NOT ATEX). The SY027 PSO has been designed for applications where a pulse is required to be isolated, re-powered and repeated on two separate outputs. It works with inputs from reed switch signals, Opto coupler, open collector, NAMUR or TTL pulse (up to 25V) with automatic debounce, as well as with high frequency pulses. The speed of pulses can be accommodated from either a very slow to super-fast. Isolated relay outputs can be created by the PSR version when an NPN pulse output from a meter needs to be converted to a single relay isolated output or two.

  • Trace Level Chemiluminescence NO-NOy Analyzer

    Model T200U NOY - Teledyne Advanced Pollution Instrumentation

    The Model T200U NOy analyzer has been developed and refined specifically to address the challenges of NOy monitoring as required, for example, in the US NCore network. It uses the proven chemiluminescence principle and is coupled with a remote NOy converter via umbilical to allow measurements with a lower detectable limit of 50 ppt.The Model T200U NOy analyzer combines a gold plated reaction cell with an enhanced performance pump, special low noise photomultiplier tube, and unique signal conditioning to provide exceptional sensitivity. In addition, a pre-reactor separates the NO-O3 reaction from background chemiluminescence to allow accurate auto-zero of the analyzer. The remote NOy converter is provided with a stainless steel, NEMA 4X (IP65) enclosure and custom sample umbilical to allow a mounting height of 10 meters. In addition, the converter features a unique purge circuit designed to remove residual calibration gas.

  • Trace-Level Photometric Ozone Calibrator

    Model T703U - Teledyne Advanced Pollution Instrumentation

    The Model T703U is a microprocessor controlled ozone calibrator for precision gas analyzers. Expanded ozone audit levels have created a need for precise ozone calibration well below the capabilities of standard calibrators. The Model T703U is designed to meet the requirements of ultra-low ozone production.In addition to a high range with similar performance to the Model T703, the Model T703U has the capability to generate ozone in a low range, or "fractional" mode, for producing ozone levels down to 3 ppb, with exceptional accuracy. Flow rate and lamp intensity are adjusted to deliver a specified ozone concentration by volume. The temperature and pressure compensated photometer, identical to that of the Model T400 ozone analyzer, provides feedback control of the UV lamp intensity, assuring stable ozone output. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the T703U, covering time periods up to a year.

  • Control Devices

    Circutor, sa

    Solutions for monitoring and recording any value you wish to manage (electricity, water, gas consumption, temperatures, flow rates, pressures, units produced, etc.), either through communications or through pulse logger systems. The control system family contains the LINE solution to create a comprehensive energy management systems (SGEi), LM pulse loggers and MDC controllers to avoid surcharges in the electric bill by preventing the contracted capacity in electrical installations from being exceeded.

  • Mini-Test Station

    Fuel Cell Technologies, Inc

    Mini-Test Station for low current fuel cell testing. The test station includes Analog mass flow controllers for Anode and Cathode gas streams, humidity bottles with preheaters and temperature controllers and a cell temperature controller. The test station is designed to use the customer's Potentiostat to load the cell. Manual backpressure is provided for pressures from 0-60 psig. The Mini-Test station is basically our Analog Mass Flow Controlled Low Flow Humidification System with all the options.

  • Interconnect Products

    Oxley Group

    Typical industrial applications for Oxley Interconnect products include high voltage power supplies, critical computer hard drives, fire safety control equipment, medical and pharmaceutical equipment, oil and gas control systems, power generation and distribution equipment, rail and telecommunications infrastructure. Within aerospace and military markets Oxley products are typically found in aircraft, military vehicles, ground base stations, surface ships and submarines and air and ground communications equipment.

  • MASTER FUEL PRESSURE TEST KIT

    FIT550 - Matco Tools

    *Performs running, residual, rail and flow rate pressure tests*Large, easy-to-read 3-1/2" dual-scale gauge reads 0-100psi and 0-700 kPa*Kit includes: 50+ adapters, fittings, 48" hose, pressure relief and fuel discharge hose to test most domestic and foreign fuel injection systems*Also includes quick release couplers and adapters to fit other fuel injection test kits*For use with gas engines only

  • Calibration Systems

    WIKA Alexander Wiegand SE & Co. KG

    WIKA's robust and modular calibration systems are designed for checking the SF6 gas density and pressure measuring instruments. The test item is connected to the calibration system via an adapter and, by pressure generation with a hand pump, makes it possible to exactly approach the measuring points. A subsequent comparison of the displayed values of the test item and reference instrument allows assessing the instrument's suitability for on-site use. The instrument is always protected and ready for use with the robust service case and an additional foam insert.

  • Oxygen Monitoring System

    Oxytron 2000 - Bacharach, Inc.

    The Neutronics Oxytron 2000 is a custom-configured instrument designed to automatically control oxygen in process applications. When combined with a properly designed sample conditioning package, the Oxytron 2000 provides reliable measurement and control of oxygen, keeping it at a safe level by controlling the flow of inert gas into the process. Originally developed for one of the country’s largest chemical manufacturers, the Oxytron 2000 has been proven reliable in thousands of installations and can provide control for two independent vessels or processes.

Get Help