Showing results: 841 - 855 of 1389 items found.
-
CS-3A -
ALS Co., Ltd
The CS-3A Cell Stand is adopted with CHI series Electrochemical Analyzers and other apparatus directly. The cell is enclosed in a Faraday cage to reduce electrical interference. A built-in gas control allows purging a sample. Gas line is provided to purge next sample, while analyzing the present sample separately, thus increasing productivity. Magnetic stirrer allows for controlling the mixing of the sample for experiments requiring mass transport of electrolyte or analyte to the electrode surface. Cell top positioner with detachable cell cap allows easy removal and replacement of the cell vial as well as the electrodes for rinsing, cleaning, and replacement.
-
HY-OPTIMA™ 1700 Series -
H2scan Corp.
H2scan’s HY-OPTIMA™ 1700 series in-line, real time hydrogen-specific process analyzers are designed for ease of use, interface flexibility and true process control. The HY-OPTIMA™ 1700 series is an ATEX certified Intrinsically Safe (IS) device that incorporates our patented solid-state sensor and is configured to operate in background gas streams with up to 95% relative humidity and temperatures up to 60ºC. The HY-OPTIMA™ 1700 series is ideal for process gas applications where real time continuous measurements of hydrogen can increase process plant efficiencies, improve diagnostics and enhance maintenance management translating into higher profitability.
-
CDQC -
Teledyne Analytical Instruments
Teledyne’s Carbon Dioxide Quality Control (CDQC) system offers an integrated package to continuously monitor impurities in carbon dioxide (CO2). The plug-and-play design allows for the user to select only the gases and features of interest to maximize cost benefit and space.Front door viewing windows allow for view of all analyzer displays, flow and pressure settings. Stainless steel tube fitting connections and NPT or metric electrical ports as required are conveniently located in a central location for ease of access. Sample conditioning, utility gas provisions and integral calibration gas solenoid valves are standard.
-
CAT-O3 Series -
Teledyne Advanced Pollution Instrumentation
The CAT-O3 series of ozone destructs safely decompose high concentrations of ozone gas to sub-ppm levels that are below recommended ozone safety limits. The catalytic method of decomposition uses a metal oxide catalyst to passively convert the ozone to oxygen.
-
CG-196 -
EverBeing Int'l Corp
Everbeing controlled environment probe station allows vacuum and cryogenic probing down to 77K with liquid nitrogen or high temperature probing up to 1273K. Efficient in characterizing your devices at extreme temperatures, vacuum, specific gas, etc.
-
M-Bus -
Anybus
M-Bus (Meter-Bus) is a European standard for remote reading of measuring devices. M-Bus is predominantly used in buildings, for example in electricity meters, gas meters, water meters or other types of consumption meters. It is also used for various sensors and actuators.
-
InfraTec GmbH
Infrared detectors for gas analysis, flame detection and radiometry in TO18 or TO39 packages.Housing types TO18 and TO39Voltage or current modeSignal processing with JFET or operational amplifierThermally compensated (optional)With special chip holder for reducing the microphonic sensitivity (optional)
-
Nautilus WM1.7-30 -
Teledyne Marine ODI
Teledyne ODI's patented Nautilus is recognized as the leading choice for high reliability wet-mateable, multi-channel electrical connectors. Over 100,000 Nautilus connectors have been delivered for projects in diverse industries including oil and gas, oceanography, and defense.
-
SPY Inspection Equipment
The Spy Pig Tracker is an electronic pig locating system that will locate your pigs wherever they go – through gathering lines, mainline transmission lines, municipal gas, water and waste water lines, refinery and other industrial piping.
-
Teledyne Marine ODI
The Teledyne Oil and Gas 10 kV subsea power electrical connection system is a three-phase system rated to 250 A and 6/10 (12) kV. The electrical connection system is designed to provide power to motors used for subsea pumping systems.
-
POLB HD 7% -
Lifasa - International Capacitors, SA
They are self-regenerating condensers with low loss polypropylene dielectric, filled with N2 inert gas mainly, or with resin, and with overpressure disconnection system, which offers a high level of safety against defects, when cutting the 3 phases in case of action.
-
Shimadzu Corp.
The Shimadzu Nexis GC-2030 gas chromatograph and HS-10 headspace sampler can now be controlled by Waters' Empower chromatography data system. The Nexis GC-2030, offering the world's highest level of performance and a user-friendly interface, can now be used in the Empower environment.
-
RY2 -
Shanghai Jiuzhi Electric Co., Ltd.
This precision test cell measures the dielectric properties of solid insulants like paper, plastic foil, etc.Basically the test cell consists of a heatable, shielded plate capacitor which is protected by a bell jar and can be evacuated and filled with protective gas.
-
Fiaxell Sàrl
When long term electro-chemical tests (>1000 hours) are run to monitor the cell degradation at the cathode for example, it is important to avoid any contaminant in the gas flow rate.Inconel 601 flange equipped with alumina housing and alumina tube to feed the gas to the electrode during long term test (>1000 h)Typical poisoning is coming from the chromium contained in the steel tubing. The volatile chromium species (Cr6+) will flow into the cathode (with the air) and thanks to the intake of electrons at the electrode, the chromium ion will transform to chromium oxide and be deposited at the cathode triple point. In such a case, the long term test kit is used. The Inconel 601 flange is equipped with an alumina housing (>96 % Al2O3) and the air (or other gas) is led through an alumina tube. The long term test kit is fully compatible with other functionalities proposed with the Open Flanges™ test Set-Up as the integrated steamer or the small pellet test kit. The long term test kit can be implemented on the fuel, on the air or on both sides.
-
PCA-400 -
Bacharach, Inc.
Bacharach’s active sample conditioner is used to enhance the performance of the PCA® 400 combustion and emissions analyzer in heavy industrial and commercial settings. The PCA® 400 provides accurate readings for CO, O2 and NO with a standard probe. Bacharach also offers optional Viton™ tubing with the sample conditioner to eliminate sample dropout, ensuring accurate results in applications where NO2 and SO2 measurements are necessary. The sample conditioner removes water vapor from the stack gas sample, preventing the formation of water droplets inside the analyzer’s probe hose. Water in the sample hose could absorb a portion of the gas sample and result in lower than actual readings of NO2 and SO2. The water extracted from the gas sample is pulled out of the thermoelectric (Peltier) cooler and into a water catch pot. The dry, conditioned flue-gas sample is then passed through to the PCA® 400 for analysis, ensuring a clean, dry, accurate air sample. This also prevents water passing into the instrument and possibly damaging the sensors or other components.