Showing results: 1081 - 1095 of 7331 items found.
-
INFINITY-CT A7CT-USB -
JFE Advantech Co., Ltd.
Infinity-CT is an autonomously deployable data logger for temperature and salinity measurements. The conductivity sensor has a design of 7-electrode. The small-sized instrument (Φ54mm x 255mm, 0.7kg in air) can be deployed and integrated virtually anywhere. The instrument has two depth rating versions: shallow water (200m, A7CT2-USB) and deep water (2,000m, A7CT-USB).
-
RINKO I / I D -
JFE Advantech Co., Ltd.
Rinko I is an autonomously deployable data logger with a fast response optical DO sensor. The instrument and the software with various operating mode offer flexible observations in the field. The small-sized and the self-contained unit with batteries and a data logger can be easily integrated on platforms (e.g. CTDs). Rinko ID has a depth sensor, allowing for DO vertical distribution measurements.
-
INFINITY-Turbi ATU75W2-USB -
JFE Advantech Co., Ltd.
Infinity-Turbi is an autonomously deployable data logger for long-term turbidity measurements. With dual sensors for low (0 to 1,000 FTU) and high (0 to 100,000 ppm) ranges, the instrument can provide Highly accurate turbidity measurements in normal to muddy water. Infinity-Turbi has a mechanical wiper to keep the optical window clean, making long-term observations possible. The instrument has temperature and depth sensors as standard as well, and matches various measuring situations and applications.
-
Com-Power Corporation
Log Periodic antennas allow quick sweep measurements without a band break. This feature makes it convenient to use the Log Periodic antenna with a automated emissions or immunity measurement system. The size of the antenna also allows it to be used in a small area like a shield room.
-
KerrMapper S300 and V300 -
MicroSense, LLC
The KerrMapper family of tools utilizes the longitudinal Magneto-Optical Kerr Effect (MOKE) to characterize the magnetic properties of magnetic multi-layer wafers for data storage, MRAM, and other magnetic sensors. Utilizing a non-contact full-wafer measurement technique, the KerrMapper S300 and V300 systems create a map of the magnetic properties of entire wafers.
-
FLIR A6750 SLS -
Teledyne FLIR
The FLIR A6750 SLS longwave camera is the ideal choice for high-speed thermal events and fast moving targets. It offers extremely short integration times and windowed frame rates above 4,000 Hz, so you can freeze motion or achieve accurate temperature measurements on moving subjects. The 327,680 (640 x 512) pixel IR resolution and high sensitivity produce crisp imagery, well suited to electronics inspections, scientific research, and more.
-
MZC-304 -
Sonel S.A.
# Measurements of impedance in a short circuit loop.- L-PE circuit,- L-N, L-L circuit,- L-PE(RCD) circuit - without tripping the circuit breaker > 30mA.# Low voltage resistance measurement:- continuity measurement - DC current +200mA with wire resistivity reset- low current resistance measurement with accoustic signalling,
-
L2000 -
Appointech, Inc.
3-in-1 as loss meter, light source, and power meter As loss meter Measure fiber loss at 1310nm and 1550nm As light source Single-head selectable output wavelength of 1310 or 1550 nm Ultra high output stability 0.05dB High output power preset at 0 dBm, or at customer-defined value Selectable CW, 270 Hz, 1KHz or 2KHz modulated output As power meter Calibrated outputs at 850, 1310, 1490, 1550, and 1625nm Data storage, logging, and PC up-loading Interactive measurements via PC Calibration on-site with customer's own standard if needed Selection of relative/absolute power measurement Display measurement in dB, dBm, mW, uW, nW Resolution 0.01dB; absolute accuracy 0.25dB For both single-mode and multi-mode optical fiber Small size, easy for field applications Light weight, less than 0.2Kg Auto power shut-off Enable / Disable Auto laser shut off at above 60oC Rechargeable battery, Battery-full and Battery-low indicator Changeable receptacle connector FC, SC, ST
-
EDB GmbH
Loudness Measurement and Monitoring according ITU-R BS.1770.3, EBU R-128 and ATSC A/85, incl. True Peak Measurement for all sub-channels incl. oversampling for enhanced accuracy, Loudness Range calculation and much more
-
Actus Digital
The Actus Loudness module lets operators maintain continuous measurements, which among other things, identifies program loudness and loudness range. Loudness measurements combined with robust logging allow users to quickly review the status and provide continuous, exportable measurements as proof of compliance and to defend against loudness complaints.
-
Echo -
Acoustic Engineering
The Echo Speech Source Type 4720 is a small active loudspeaker box providing calibrated acoustic signals for speech intelligibility measurements using the Dirac room acoustics software. The Echo Speech Source is typically placed at a human speaker position. The received signal at the listener position is then picked up by a microphone and analyzed in Dirac to arrive at an accurate qualification of the speech intelligibility through parameters such as the Speech Transmission Index (STI). The Echo Speech Source operates from 4 AA batteries or an external mains power supply, and can be mounted on a standard tripod.
-
RTS SERIES -
Transducer Techniques, Inc
The RTS Series torque sensors were designed to fill the need for accurate torque measurements below 62.5 in.lbs. without giving up stiffness or sensitivity to forces from other directions. They are manufactured from sensor quality aluminum and anodized for long term durability. Bonded foil strain gages and materials of the highest quality are installed assuring high reliability. The four bolt hole pattern with the use of our O.D. or I.D. pilots on either end allows simple adaptation to any application.
-
DMM 124 -
Tecpel Co., Ltd.
8 Functions, 23 ranges. DCV, ACV, and Ohms measurement. Capacitance 20£gF~20mF. Frequency measurement 10Hz to 40kHz. Type K Temperature measurement ¡V20¢J~750¢J, -4¢K~1400¢K
-
IMV Corporation
A compact Signal Amplifier to make optimal signal processing being connected with the Servo type Accelerometers. It is used for Vibration Acceleration Measurement, Waveform Observation, for various Analysis in combination with the AC Voltage Meter, Oscilloscope, FFT Analyzer respectively. Furthermore, Voltage signals from the Microphones or Sound Level Meters can be output to the instruments like Recorders along with the Vibration Signals.
-
EM Electronics
This instrument has a very wide range of source resistance capability and has an equivalent noise resistance of less than 10 ohms. Sub-nanovolt resolution is possible. The N11 has many applications, including cryogenic measurements.