Probing
See Also: Probers, Probing Stations, Nano Probes
-
product
Interface Probes
Low resistance used in: *ICT Testers *Functional Testers *Special Purpose Machines
-
product
High 2.84 (81.00) - 8.00 (227.00) High Performance Lead Free Probe
LFRE-25J-8
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Probes, Magnetic Field
EM-6881 | 480 KHz To 30 MHz
The EM-6880, EM-6881 and EM-6882 Magnetic Field Probes operate in conjunction with any 50 ohm input impedance receivers.
-
product
Exhaust Gas Thermocouple
LM2500 T5.4
AMETEK is the original OEM for the T5.4 EGT. We supply the L44830P01, L44830P02 and L44830P03 probes for use on the LM2500, LM2500+ and LM5000 gas turbines. In addition to the EGT, we also provide rigid harness, T3 probes, cables and flexible harness for these engines. Ensure you get the highest quality by selecting OEM qualified parts to keep your engine running reliably.
-
product
Immersion Probe For Liquid
DPT-12
DPT-12 Immersion Probe for Liquids - 12'' #304 stainless steel welded shaft. Wooden Handle. Diameter is .3/16'' diameter. Immersible. Maximum temperature 350°C, Time constant 2 Seconds. 5 foot lead. Not isolated.
-
product
Electron Probe Microanalyzer
EPMA-8050G
This instrument is equipped with a cutting-edge FE electron optical system, which provides unprecedented spatial resolution under all beam current conditions, from SEM observation conditions up to 1 μA order. Integration with high performance X-ray spectrometers that Shimadzu has fostered through the company's traditions achieves the ultimate advance in analysis performance.
-
product
Adapter/Stainless Steel
WADP-NFSF-01
Warison provides wide range of wireless passive coaxial components, includes Adapters, Attenuators, Coaxial Cables Assemblies, DC Blocks, Filters, Isolators & Circulators, Probes & Terminations. With outstanding capability of development and design, Warison is able to custom the spec based on customer��s demand. All Warison��s products pass inspection and electronic performance test before shipping out. It is our principal to deliver the best solution to all our clients.
-
product
Standard 5.95 (169.00) - 7.55 (212.00) Switch Probe
MSP-25C
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 125Full Travel (mm): 3.18Recommended Travel (mil): 85Recommended Travel (mm): 2.16Mechanical Life (no of cyles): 100,000Overall Length (mil): 1,690Overall Length (mm): 42.93Switch Point (mil): 30Switch Point (mm): 0.76
-
product
Advanced Monitoring Probe
DVB-T/T2
Combined with a Network Monitoring System or not, the EdgeProbe Advanced provides a powerful broadcast network alert & diagnosis tool allowing DTV network operators to monitor global trends and anticipate potential failures.EdgeProbe Advanced is able to monitor DVB-T and DVB-T2 signals at transmitter outputs, through its RF inputs (up to 4 in 1RU), as well as at modulator input and at Head-End/distribution links, through its ASI and IP inputs.
-
product
Radiometric Probe for Irradiance
LPUVB02
Amplified radiometric probe for outdoor use for measuring IRRADIANCE in the UVB spectral range (peak at 305 nm).
-
product
Probe Holders
Probe holders from ZEISS offer the possibility to use optical and tactile scanning probes on one CMM. With the articulating probe holder even complex parts can be measured with less effort.
-
product
Hotwire Air Speed Transmitters
HD403TS… Series
Range hotwire transmitters with 0-10 V or 4-20 mA output. Directional or omnidirectional probes.
-
product
Standard 0.81 (23.00) - 4.50 (128.00) Battery Probe
CP-059-025
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 57Full Travel (mm): 1.45Recommended Travel (mil): 40Recommended Travel (mm): 1.02Mechanical Life (no of cyles): 100,000Overall Length (mil): 313Overall Length (mm): 7.95
-
product
Isolation Probe
SE-6000/6010
Performs waveform measurements with high resolutions and in safe manner under high voltage environment in systems that isolate Input/output terminals through optical insulation
-
product
Thermocouple Vane Probe
AP472S1
Vane probe with K type thermocouple ∅ 100 mm to measure air speed in the range 0.6…25 m/s and air temperature in the range –25°C … +80°C.
-
product
Non-contact Optical Surface Profiler
VS-OSP
The VersaSCAN OSP integrates the Base with a high-accuracy, high-speed laser displacement sensor. The OSP technique uses diffuse reflection mechanism to measure topography of a sample. OSP can be used to measure topography, as a very sensitive leveling mechanism, or charting topography to be implemented with other scanning probe techniques for constant-distance mode operation.
-
product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-2
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
product
Data Logger for Extremely Low Temperature
DSR-ELT
Special probe using military industrial technology supports measuring temperature ultra low to -196 Original fittings for sensor connection, ensures 100,000 plugs Support single DSR connecting to PC via USB interface, and multiple DSR grouped in RS485 or LAN networking for central management Suitable for medical refrigerator, biological specimens preservation, scientific research and other applications
-
product
Cryogenic Probe Station
CRX-4K
Designed for versatility and high performance, the CRX-4K is our premium cryogen-free closed-cycle refrigerant probe station. This system is the solution for those looking for the convenience of cryogen-free operation and the exceptional measurement performance of a Lake Shore product.
-
product
Alternate 2.39 (68.00) - 6.00 (170.00) High Performance Bias Ball Probe
POGO-1L-6
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Probe Holders
Model P7
Made from 300 series stainless steel, the P7 probe holders accept all model 407 replaceable probe tips, and are secured with a set screw. When used with the P7 Tool Holder Adapter Arm; “Z” position adjustments are easy, and can accommodate a variety fixtures and probe card holders. Designed for both high temperature (-65 to 300°C) and high electrical isolation measurements.
-
product
Interchangeable Probe Active Transmitters
HD2817T…Series
The instruments of the HD2817T… series are transmitters, indicators, and ON/OFF regulators with data logging functions, they measure temperature and humidity. The instrument has a large, backlighted, graphical display.
-
product
Emissions Test System
PC-114
Perform Radiated & Conducted EMI pre-compliance testing at your facility up to 1 GHz. Com-Power PC-114 EMI emissions test system is a ideal solution performing pre-compliance EMC testing from 9 kHz - 1 GHz.. It has essential equipment needed for radiated and conducted EMI emissions measurements. The system includes a spectrum analyzer, antennas, near field probes, a preamplifier, LISN and a non conductive antenna tripod. Pre-compliance testing in EMC is a commonly used term not easy to define. In general, it implies testing done prior to formal testing for legal compliance. Formal legal compliance is performed at a facility designed and equipped with test instrumentation that is fully compliant with the applicable EMC standards. Such facility and instrumentation is capital intensive and can be expensive even to rent and not easily available. Compliance testing is performed per exacting requirements of the Standards and other reference documents adhering to the test methods and last detail. In addition, the test facility may require to be accredited by an accreditation body such as NVLAP, A2LA. Often it is desirable to know prior to compliance testing at such facility, whether a product is close to compliance and also how close. Pre-compliance testing is specially useful for specifications such as FCC, Part 15, EN 55022 or EN 55011 (CISPR 22 or CISPR11). Pre-compliance testing usually means using the full compliance methods but making a few educated compromises in use of site or equipment to reduce costs and testing time. Here are some benefits of pre-compliance testing.
-
product
Oscilloscope, 100 MHz, 2 GS/s interleaved, 4 CH, 200 Mpts/Ch DSO, Fully Loaded with 10.1" Color Display
T3DSO2104HD
The T3DSO2000HD series of Bench Oscilloscopes feature 4-channel models with analog bandwidth options of 100 MHz, 200MHz and 350 MHz. The T3DSO2000HD Oscilloscopes use 12-bit high resolution ADCs and a low noise front end which provides an impressive noise performance to cover a wide range of measurement applications. Each model offers a maximum sample rate of 2 GSa/s (interleaved) and a maximum memory depth of 200 Mpts in interleave mode. The MS configured models also include a 16 channel logic probe as standard.
-
product
InfiniiMax Probe, 5 GHz
1132B
Provides extremely low input capacitance, flat frequency response, and patented resistor probe tip technology.
-
product
Bulk Current Monitoring Probe
MP-50
The Current Monitoring probes may be used whenever RF current measurements are required. Current measurements are made by placing a current carrying conductor within the “sensing” window of the probe and measuring the probe’s output voltage with an RF detector. Calibration of the probe permits the conversion of the voltages measured to current. Current measurements can be made over the frequency range shown in the transfer impedance curve furnished with each probe. There is virtually no loading of the circuit and the technique permits normal operation of the device under test during measurements. The MP-50 can be used for the procedure for clamp injection when the common- mode impedance requirements cannot be met given in chapter 7.4 of IEC/EN 61000-4-6 „Immunity to conducted disturbances, induced by radio frequency fields”. The MP-50 can also be used as current monitor for BCI testing as per ISO11452-4, RTCA/DO-160 section 20, MIL-STD-461 and various automotive standards.
-
product
Relative Humidity & Temperature Probe
HMP7
Vaisala HUMICAP® Humidity and Temperature Probe HMP7 is designed for applications which involve constant high humidity or rapid changes in humidity such as drying and test chambers, combustion air and other humidifiers and meteorological measurements where measurement performance and chemical tolerance are essential.
-
product
Super 3.90 (111.00) - 16.00 (454.00) High Performance Lead Free Probe
LFRE-25V-16
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
ProBus Probe Adapter for TekProbe-BNC Probes
TPA10
- Allows TekProbe interface level II probes to work with any ProBus-equipped Teledyne LeCroy oscilloscope- Automatic probe detection- Provides all necessary power and offset control to the attached probe- Supports probes up to 4 GHz- Easy firmware updates- Wide variety of probes supported including: Preamplifiers, Current Probes, Single-Ended Active Probes and Differential Active Probes