Teledyne LeCroy
Teledyne LeCroy is a leading provider of oscilloscopes, protocol analyzers and related test and measurement solutions that enable companies across a wide range of industries to design and test electronic devices of all types. Since our founding in 1964, we have focused on creating products that improve productivity by helping engineers resolve design issues faster and more effectively.
- (800) 553-2769
845 425-2000 - 845-578-5985
- contact.corp@lecroy.com
- 700 Chestnut Ridge Road
Chestnut Ridge, NY 10977-6499
United States of America
-
Product
2.92mm to ProLink Adapter with Probe Power and Communication Pass Through
L2.92A-PLINK
-
The Teledyne LeCroy LabMaster 10 Zi oscilloscope utilizes precision 2.92mm input connectors to achieve up to 36GHz of input bandwidth. But some applications may require the use of lower-bandwidth probes for performance and cost reasons.The L2.92A-PLINK adapter converts the 2.92mm interface to a ProLink interface. This brings the benefits of a wider selection of probes to the LabMaster 10 Zi such as Dx10/Dx20/Dx00A-AT 4-6 GHz differential probes and DH Series 8 to 20 GHz differential probes using the ProLink oscilloscope probe connection. Full probe power and control is provided through a built-in LEMO interface.
-
Product
D.C Milli-Ohm Meter with Advanced Features, 4-Wire, Handler/RS-232C/USB Device/GPIB
T3MIL50X
-
D.C Milli-Ohm Meter with Advanced Features, 4-Wire, Handler/RS-232C/USB Device/GPIB.
-
Product
Replacement Solder Tip Leadset for Use with D410/D610
Dx10-SI-HiTEMP
-
The 90 cm HiTemp cables and Solder-In lead can be used for controlled situations where the differential amplifier module needs to be removed from the extreme temperature environment. Ideally suited for testing scenarios where the temperature can fluctuate from -40 °C to +105 °C.
-
Product
4.0 GHz, 0.6 pF, 1 MOhm Active Voltage Probe
ZS4000
-
Engineers must commonly probe high frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies, but inappropriately load the circuit, and distort signals, at higher frequencies. The ZS Series features both high input R (1 MΩ) and low input C (0.6 pF) to reduce circuit Loading across the entire probe/oscilloscope bandwidth. The ZS4000 is ideal for 2.5 GHz and 4 GHz oscilloscopes.
-
Product
Function / Arbitrary Waveform Generators
Arbitrary Waveform Generator
Teledyne Test Tools generate fixed or arbitrarily defined waveforms and signals for use in the development, testing and repair of electronic systems.
-
Product
1520W Single Channel 19", 1U, Rack Mounted DC Power Supply
T3PS40381P
DC Power Supply
1520W Single Channel 19", 1U, Rack Mounted DC Power Supply.
-
Product
7.5 GHz Low Capacitance ÷10/÷20 probe
PP066
-
The PP066 is a high-bandwidth passive probe designed for the use with the WaveMaster™ and other high-bandwidth oscilloscopes that have 50 Ω input termination. This very low capacitance probe provides an excellent solution for higher frequency applications, especially the probing of transmission lines with 20–100 Ω impedance.
-
Product
AC Current Probe 2 mV/A, 3,000A, 0.11 Hz LF Bandwidth, 6.5MHz HF Bandwidth, 4m cable, 300mm coil
T3RC3000-LF
-
AC Current Probe 2 mV/A, 3,000A, 0.11 Hz LF Bandwidth, 6.5MHz HF Bandwidth, 4m cable, 300mm coil.
-
Product
WaveRunner Oscilloscope, 1 GHz Bandwidth, 4+16 Input Channels, 20 GS/s on 2 Ch Sample Rate
WaveRunner 9104
Oscilloscope
1 GHz, 20 GS/s, 4ch, 16 Mpts/Ch DSO with 15.4" Capacitive Display.
-
Product
HD Arbitrary Waveform Generator,8 Ch,250 MHz,16 bit,128Mpts/Ch,6 Vpp output,AFG/AWG, Wave Sequencing
T3AWG3258
Arbitrary Waveform Generator
HD Arbitrary Waveform Generator,8 Ch,250 MHz,16 bit,128Mpts/Ch,6 Vpp output,AFG/AWG, Wave Sequencing.
-
Product
250 MHz Passive Probe for WaveSurfer3000, 10:1, 10 MOhm
PP019-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
Bench Power Supply, Switching DC, Adjustable, 1 Output, 0 V, 12 V, 0 A, 30 A
T3PS11230
Power Supply
Bench Power Supply, Switching DC, Adjustable, 1 Output, 0 V, 12 V, 0 A, 30 A.









































































