Teledyne LeCroy
Teledyne LeCroy is a leading provider of oscilloscopes, protocol analyzers and related test and measurement solutions that enable companies across a wide range of industries to design and test electronic devices of all types. Since our founding in 1964, we have focused on creating products that improve productivity by helping engineers resolve design issues faster and more effectively.
- (800) 553-2769
845 425-2000 - 845-578-5985
- contact.corp@lecroy.com
- 700 Chestnut Ridge Road
Chestnut Ridge, NY 10977-6499
United States of America
-
Product
2.92mm to ProLink Adapter with Probe Power and Communication Pass Through
L2.92A-PLINK
-
The Teledyne LeCroy LabMaster 10 Zi oscilloscope utilizes precision 2.92mm input connectors to achieve up to 36GHz of input bandwidth. But some applications may require the use of lower-bandwidth probes for performance and cost reasons.The L2.92A-PLINK adapter converts the 2.92mm interface to a ProLink interface. This brings the benefits of a wider selection of probes to the LabMaster 10 Zi such as Dx10/Dx20/Dx00A-AT 4-6 GHz differential probes and DH Series 8 to 20 GHz differential probes using the ProLink oscilloscope probe connection. Full probe power and control is provided through a built-in LEMO interface.
-
Product
T3CP Series AC/DC Current Probes
T3CP Series
-
Teledyne Test Tools AC/DC Current Probes are powered by an external universal power supply and work with any Oscilloscope with a high-impedance BNC input. The range of five current probes includes models with bandwidths up to 100 MHz, peak currents up to 500A and sensitivities to 1 mA/div.
-
Product
Vector Network Analyzers
-
The Teledyne Test Tools range of T3VNA Vector Network Analyzers consist of two models with a Vector Network Analysis frequency range of 10 MHz up to a maximum of 3.2 GHz and a Spectrum Analysis frequency range from 9 kHz up to a maximum of 3.2 GHz. The small footprint and easy user interface is augmented by a high performance specification with many advanced measurement functions and capabilities.
-
Product
T3AWG2K Series - 16-bit Dual Channel Arbitrary Waveform Generator
T3AWG2K Series
Arbitrary Waveform Generator
The T3AWG2K series consists of two affordable dual-channel arbitrary waveform generators, 16-bit vertical resolution, 6 Vpp output voltage (50Ω to 50Ω), 128 Mpts/ch memory, a maximum sampling rate of 600 MS/s and a maximum sine wave frequency of 150 MHz. The T3AWG2152-D mainframe adds 8 synchronized digital channels to the analog outputs, ideal for debugging and digital design validation.
-
Product
16 GHz Differential Probe with ProLink Interface
DH16-PL
Interface
Teledyne LeCroy’s DH series 8 to 30 GHz differential probes offer the combination of bandwidth, input range and offset capability to address any high-speed probing requirement from debugging serial data interfaces to validating DDR memory systems. DH series probes provide superior loading characteristics and are calibrated with a custom “fine-tuned” frequency response. The ultra-low loading and flat frequency response ensure accurate measurements.
-
Product
1kV, 25 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3102A
Differential Probe
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
Product
Replacement Long Alligator Clips for High Voltage Differential Probe
PK-HVA-04
-
Replacement Long Alligator Clips for High Voltage Differential Probe
-
Product
HD Oscilloscope, 500 MHz, 10 GS/s ESR, 4 CH, 500 Mpts/Ch (Single Channel), 12-Bit HD
T3DSO4054L-HD
Oscilloscope
500 MHz, 10 GS/s ESR, 4 CH, 500 Mpts/Ch (Single Channel), 12-Bit HD Low Profile Oscilloscope.
-
Product
HD Oscilloscope, 1GHz, 10 GS/s ESR, 8 CH, 500 Mpts/Ch (Single Channel), 12-Bit HD
T3DSO4108L-HD
Oscilloscope
1GHz, 10 GS/s ESR, 8 CH, 500 Mpts/Ch (Single Channel), 12-Bit HD Low Profile Oscilloscope.
-
Product
WaveLink Temperature Extension cables for Dx20
Dx20-HiTemp
-
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
Product
2.5 GHz, 20 GS/s, 4ch, 100 Mpts/Ch High Definition Oscilloscope
WavePro 254HD
Oscilloscope
HD4096 technology provides 12-bit resolution up to 8 GHz and 20 GS/s. Up to 5 Gpts of acquisition memory enables detailed viewing of long events.15.6" 1900 x 1080 Full HD capacitive touchscreen.New ProBus2 input supports up to 8 GHz bandwidth and direct compatibility with a wide variety of existing ProBus probes - 50Ω and 1MΩ coupling modes support all input types on a single connector. MAUI with OneTouch user interface for intuitive and efficient operation.Deep toolbox enables and simplifies complex analysis.Intuitive navigation to quickly find important features in long waveforms. Zone Trigger – Simple Triggering for Complex Signals.
-
Product
30A, 100MHz High Sensitivity Current Probe
CP031A
-
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
Product
Probe Adapters
-
Probe adapters provide simple and easy interface of third-party probes as well as change between the different Teledyne LeCroy Oscilloscope input and cable types (ProBus, ProLink, K/2.92 mm, BNC and SMA). Depending on the adapters, changing between the Teledyne LeCroy Oscilloscope's input type may have an effect on the overall performance of the channel.









































































