Showing results: 1 - 15 of 22 items found.
-
-
GDYZ-301 -
HV Hipot Electric Co.,Ltd.
GDYZ-301 Automatic Zinc Oxide Lightning Arrester Characteristic Tester is the special equipment of testing zinc oxide arrester electric performance.It is suitable for testing various voltage levels zinc oxide with electricity or without,thus to detect dangerous problems inside the device caused by wet insulation or valve plate aging.
-
ALCL-40L -
MULTI MEASURING INSTRUMENTS Co., Ltd.
Lightning arresters are designed to protect a power distribution system by shunting to ground the high voltage surges caused by lightning. ALCL-40L measures to warn that an arrester is damaged or deteriorated and should not be energized.
-
-
Greenlee Tools
*Designed to test lightning arresters for damage or deterioration*Live line tester tests lightning arresters prior to energizing*For use on system voltages from 4kV to 25kV line-to-line and up to 69kV with optional add-on resistor sticks*Versatile for overhead and underground applications
-
PIVM12,5-275/3+0 Vseries -
HAKEL Ltd.
PIVM12,5-275/3+0 Vseries is a three-pole lightning and surge arrester Type 1+2 according to EN 61643-11 and IEC 61643-11. These arresters are recommended for use in the Lightning Protection Zones Concept at the boundaries of LPZ 0 – 1 (according to IEC 1312-1 and EN 62305), where they provide the equipotential bonding and discharge of both, the lightning current and the switching surge, which are generated in power supply systems entering the building. The use of the lightning current arresters PIVM12,5-275/3+0 Vseries is mainly in the power supply lines, which are operated as TN-C system. The main use of PIVM12,5-275/3+0 Vseries arrester is in structures of LPL III – IV according to EN 62305 ed.2. The marking M specifies a type of construction with removable module.
-
-
-
-
-
Weshine Electric Manufacturing Co., Ltd
Lightning strike counters of lighting arrester measure lightning strikes by the induction of current and do not require the use of any external power source. Weshine invented Lightning-strike-counter Tester (VS-451) is used of verify that if strike counter is correctly mounted and connected. As well as output current with sensitivity of 0.01 mA to correct leakage ammeter.
-
GDCL -
HV Hipot Electric Co.,Ltd.
The impulse current generator is used to inspect the capacity of electric equipment withstand strong impulse current.It is widely used in lightning arrester and shock wave anti-interference test of electric and electronic equipment under their running conditions and used in other research project.
-
Weshine Electric Manufacturing Co., Ltd
Impulse current generator is mainly used to test the ability of electrical equipment to withstand strong impulse current, widely used in lightning arresters and electrical and electronic equipment in operation conditions of oscillation wave immunity test, can also be used for other research tests.
-
FM-3 -
Parker McCrory Manufacturing Co.
Power to stop the most stubborn stock! For small to medium pastures. The all new low impedance model for small to medium pastures features advanced solid state circuitry. Shocks through wet weeds and brush. New color coded fence and ground terminals. Red to the fence and Black to ground. Fuse protection, with built-in lightning arresters. Full 3 year warranty covers damage caused by lightning.
-
FM-3 -
Physical Sciences Inc.
Power to stop the most stubborn stock! For small to medium pastures. The all new low impedance model for small to medium pastures features advanced solid state circuitry. Shocks through wet weeds and brush. New color coded fence and ground terminals. Red to the fence and Black to ground. Fuse protection, with built-in lightning arresters. Full 3 year warranty covers damage caused by lightning.