Showing results: 991 - 1005 of 1210 items found.
-
PCE Instruments
On one hand, there are signal converters which transform an input frequency range into an analog signal. These signal converters are very easy to program and control. Other signal converters can transform analog input signals into analog normalized signals with galvanic insulation. Due to the fact that these signal converters can be freely graduated, they offer endless possibilities and 110 combinations can be selected by means of a DIP switch. Other kinds of signal converters can be connected to devices with RS-232, RS-485 or RS-422 protocols.
-
The Rotation Link SAS
Separates are typically rings and insulation material assembled on an axis along with separate contact brushes. They are usually designed with flying leads. Once integrated, they provide electrical contact between stationary and rotating parts of a slip ring assembly. They use bearings from the host system and provide a more compact and economical solution than self-contained Slip Rings. The coupling of these items requires technical skills from the OEM and is suitable for applications that have tight mechanical requirements.
-
19035 -
Chroma ATE Inc.
The quality verification tests for wound components consist mainly of AC/DC Hipot tests and insulation resistance (IR) tests. The Chroma 19035 wound component EST scanner series perform safety tests for motor, transformer, and heater related wound products.
-
19070 -
Chroma Systems Solutions, Inc.
The Sentry 19070 Hipot Tester series provides 2 models to choose from. The Sentry 19071 for AC Hipot testing; and the Sentry 19073, which combines both AC and DC Hipot with insulation resistance (IR) measurements into a single compact unit.
-
Koyo Electronics Industries co., ltd
The Coil Tester can measure the number of winding, layer short and core material by comparing vibration waveforms of the applied voltage to the standard coil and the test coil. This instrument also can find an insulation failure by applying high pulse voltage and checking the corona discharge.
-
DPC series -
UDEYRAJ ELECTRICALS PRIVATE LIMITED
DPC series hipots are used for proof testing of high voltage equipment in power engineering. Routine testing of the insulation and leakage is a necessary requirement for electrical equipments. Other areas include: Cable breakdown testing, capacitor charging and general laboratory use.
-
Botron Inc.
Botron's Digital/Analog Audit Kit insulation and continuity tester is designed for electrical testing. The wide range of test voltages makes the Audit Kit ideal for users involved with ESD testing. The kit gives greater functionality with simplified operation and an ergonomically designed case.
-
Power Diagnostix Systems GmbH
Partial discharge monitoring systems can be used for permanent surveillance of insulation systems on GIS, transformers, rotating machines, motors, cables, or other high voltage equipment. These instruments are designed for long term data recording, alarm handling, event recognition, and system integration.
-
TM800 -
T&M Tools Limited Co
TM800 Cable Fault Locator is a portable field instrument working on TDR and bridge methods, adopting advanced micro-electronics technology. It is designed to locate accurate fault points in such cables as telecommunication leadsheathed cable, plastic cable or user’s lead covered wire, while the faults include break, mix, earthing, defective insulation, or poor connecting. It is and ideal function-stable instrument for the field operator to improve work efficiency, in addition, it can also be used for circuitry project checking electric property testing of the cable.
-
PCT 1 -
Shanghai Powoo Industry Develop Group Limited
- completely enclosed, good mechanical behavior, suitable for various environments, strong voltage isolation ability, delicate appearance; - the secondary lead wire is pin format, which can be directly welded on a PCB; - the primary lead wire could be pin, soft wire as well as tin-plated copper-core wire; - linear output current, high precision; - small volume, light weight, easy for installation; - encapsulated with epoxy resin to ensure strong insulation ability; - ABS anti-combustion plastic casing.
-
92-965-200-M -
Pickering Interfaces Ltd.
Suitable for use on the front of PXI modules this connector block provides a simple method of connecting to high density 200-Pin LFH connectors. The screw terminals use a rising cage screw clamp mechanism to minimize risk of copper strand breakage. PTFE cables are recommended for use with this connector block to maximize copper cross sectional area and insulation properties. Users should make their own cable strain relief arrangements and ensure that appropriate electrical safety precautions are observed.
-
Hilkar
Since the rise time of IGBTs are in the range of a few tens of nanoseconds (between 50ns-200ns), even short cables between PWM motor drives and motors cause voltage doubling at the motor terminals due to Travelling Wave Phenomenon as in transmission lines. The insulation of motor windings are prone to failure due to high voltage spikes if necessary precautions are not sufficiently taken. RC Type Output Filter Modules reduce these high voltage spikes to protect motors by connecting to stator terminals.
-
DE-5030 -
DER EE Electrical Instrument
Earth resistance range0~12 / 0~120 / 0~1200 Normal operation conditionsBattery voltagein range of "BATT.GOOD" Earth voltage measurementmax. AC 30V Output current3mA Response timewithin 1 sec. Insulation resistancemin. 100M / DC1000V between input terminals and case Withstand voltageAC3700V (50 / 60Hz) for 1 min. between input terminals and case Battery Check Battery1.5V x 4 Safety standardIEC 61010-1 CAT.III 300V IEC 61557, IEC61010-031
-
Eltel Industries
*Measures Ratio, Excitation Characteristics, Polarity, Winding Resistance, Remanance, and Insulation Resistance of secondary winding. * Determines Composite Error. * Used to test un-mounted CTs or CTs that are mounted but isolated inside the power system equipment. * Conducts a whole series of tests automatically, thus speeding up the time to commission CTs and relaying systems. * Battery powered test set - light weight & fully portable. * Provides a graphical presentation of the CT excitation characteristics. * Determines the IEC 10/50 knee point and the point of maximum permeability, ANSI 45 degree Slope Point. * Detects shorted turns or insulation problems within the test CT, thus avoiding commissioning of faulty equipment.
-
CTT -
ndb Technologies Inc.
The CTT is designed to test the current transformer ratio, Phase shift, Polarity, Excitation, Saturation, Winding resistance and Insulation resistance using the voltage method in compliance with ANSI/IEEE C57.13.1 and IEC 60044-1 standards, where voltage is applied to the secondary X terminals of the current transformer.