Showing results: 1081 - 1095 of 1232 items found.
-
ZY-3/ZY-3S -
Lisun Electronics Inc.
According to IEC60695-2-2 and IEC60695-11-5, ZY-3/ZY-3S Needle Flame Test is applied in the production and quality control department of lighting instrument, hyperpiesia electrical apparatus, domestic appliance, machine electric appliance, electrical machine, power tool, electronic instrument, electrician instrument and technical equipment. Also, it is fit for the industry of insulation material, engineering plastics and solid combustible material.
-
Part No. SHP24N50R -
Teledyne Defense Electronics Relays & Coax Switch
The Series SHP phase-angle controller provides analog switching. It features an internal microcontroller and overvoltage protection. Choose relays with either removable input spring connectors or IP20 touch-proof flaps. The relays are designed in conformity with EN60947-4-3 (IEC947-4-3)and EN60950/VDE0805 (Reinforced Insulation), and feature Phase Angle switching.Available options include:SHP24N50R 50A, 9-280Vac, 600Vpeak Load; 4-20mA Control
-
MPI-520S -
Sonel S.A.
The MPI-520S multifunction meter is dedicated to perform diagnosis of electrical installation according to IEC 61557 standards. Digital meter MPI-520S is designed to measure impedance of a short cicuit loop also without triggering RCD, parameters of RCD, insulation resistance, earthing resistance, continuity and also for phase sequence testing. Furthermore to measure and logging of AC voltage and current, frequency and power.
-
Frida -
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR frida. The portable and powerful high-voltage testing and diagnostics device is used for cable and cable sheath testing of medium-voltage cables up to 20 kV and electrical equipment. Another function is insulation testing on electrical equipment.* Precise and non-destructive determination of the cable condition* Easy and quick test setup* Automatic testing and diagnostic sequences* Compact dimensions and lightweight
-
Shanghai Guantu Technology Co., Ltd.
The arrester is usually connected between the live wire and the ground, and is connected in parallel with the protected equipment. When the overvoltage value reaches the specified operating voltage, the arrester will act immediately, flow the charge, limit the overvoltage amplitude, and protect the insulation of the equipment; when the voltage value is normal, the arrester will quickly return to its original state to ensure the normal power supply of the system.
-
Shimadzu Corp.
It is necessary to analyze outgas in transformer insulation oil in power plant facilities. Shimadzu offers a System GC compliant with ASTM D 3612 Method B (oil stripper sampling) or ASTM D 3612 Method C (headspace sampling). The Nexis GC-2030TOGAS3 system, equipped with a PDHID, enables the analysis of more trace amounts of permanent gas than conventional systems.
-
19032 -
Chroma Systems Solutions, Inc.
Our Electrical Safety Analyzers combine Hipot, Insulation Resistance ( IR), Ground Bond (GB), Leakage Current (LC)/AC LC/DC LC, and Dynamic Function Tests. Savings can be up to 50% of production line space by not having to purchase and rack several safety test instruments. It also increases efficiencies of electrical safety testing and reduces associated labor costs.
-
MTC 3 -
Whitelegg Machines Ltd
The fully automatic MTC3 stator testers test your windings reliably and quickly for possible insulation faults via our patented surge voltage test.After connecting the test object completely the test is performed with an automatic switching of the connections and the test methods. The MTC3 evaluates each test step. At the end of the complete test process it provides a clear and reproducible GO or NO GO-statement.
-
Kikusui Electronics Corp.
a high performance electrical safety analyzer that complies to a wide range of universal standards. Hipot, Insulation Resistance, Ground Bond, Leakage Current (touch current and protective conductor current) and partial discharge can all be tested. A total of 6 models are available for standard compliance tests in a wide variety of applications including R&D, quality assurance manufacturing lines and laboratory tests.
-
448 -
SCI
Our 448 model is a 4-in-1 tester with 500VA AC Hipot, DC Hipot, Insulation Resistance and Ground Bond testing capabilities. The 448 is capable of a 500VA AC Hipot output to comply with 100mA leakage current test compliance requirements. This tester features a simple design and easy-to-use interface, reducing setup time and increasing production-line throughput for your application.
-
Megger Group Ltd.
Precision test equipment for communications testing applications is essential to a professional test and installation engineer’s job. Megger has been there from the start to help you and your industry customers with connectivity, reliability and maintenance. The range of test instruments includes copper wire analysers, TDRs, insulation and continuity testers, battery testers, earth testers and hand-held network performance testers.
-
Power Diagnostix Systems GmbH
Partial discharge measurement is a useful tool to analyze the insulation of high voltage components. However, partial discharges can usually not be measured directly, just the apparent charge of such signals are captured by the measuring instrument. Therefore a calibration of the whole measuring system is required in principle. Hereby short-duration current pulses of known charge magnitude are injected into the system, and by this a scale factor can be calculated for later PD measurements.
-
C Model -
PJ Electronics, Inc.
These Digital High Frequency Surge Testers are the ultimate in ruggedness & durability. Fourteen / sixteen gauge steel construction and mobility on 6" heavy duty rubber wheels makes it a favorite for use in harsh industrial environments. The performance of PJ's exclusive/unique High Frequency Technology is capable of testing the integrity of any turn-to-turn insulation, including low inductance windings.
-
MB Model -
PJ Electronics, Inc.
Bench all-in-one versatile Multi-Operational Surge Tester that you need for all of your electrical insulation testing. The Hi-Pot tester has separate L.E.D. panel meters for direct readout (voltage and leakage current) so that no interpolation on the scopes display is ever needed. This MOST can surge test extremely low inductance windings, DC armatures, etc.
-
FLIR MR265 -
Teledyne FLIR
The FLIR MR265 is a professional pin and pinless moisture meter with thermal imaging designed to show you exactly where to investigate issues related to moisture, air leaks, and insulation voids. Featuring IGM™ (Infrared Guided Measurement) and MSX® (Multi-Spectral Dynamic Imaging enhancement) technology, the MR265 helps you quickly scan and target problem areas, visually guiding you to the spot where you can confidently take measurements, analyze readings, and ensure that problems are fixed. Using FLIR Thermal Studio™, you can then create and share professional reports that include findings and proof of repairs – giving your clients peace of mind that mold, rot, or moisture challenges have been resolved.