Showing results: 661 - 675 of 1233 items found.
-
7410 -
Peaceful Thriving Enterprise Co Ltd
Find short and open circuits fast and easily. It is designed to identify and trace wires or cables without damaging the insulation; you just simply attach the sender unit to the circuit and follow the wires by using the detector. There is a sender and a receiver included in the instrument.
-
A022KMR-C-HA100 -
Pickering Interfaces Ltd.
This is a 1m long male to unterminated 22-Pin REDEL high voltage cable assembly with cut ends constructed from 19/38 (26AWG) Silver Plated Copper Wire with FEP insulation. Latch clips are provided to secure the connector to associated product.
-
A022KMR-C-HA050 -
Pickering Interfaces Ltd.
This is a 0.5m long male to unterminated 22-Pin REDEL high voltage cable assembly with cut ends constructed from 19/38 (26AWG) Silver Plated Copper Wire with FEP insulation. Latch clips are provided to secure the connector to associated product.
-
A051KMR-C-HA100 -
Pickering Interfaces Ltd.
This is a 1m long male to unterminated 51-Pin REDEL high voltage cable assembly with cut ends constructed from 19/38 (26AWG) Silver Plated Copper Wire with FEP insulation. Latch clips are provided to secure the connector to associated product.
-
A022KMR-C-HA200 -
Pickering Interfaces Ltd.
This is a 2m long male to unterminated 22-Pin REDEL high voltage cable assembly with cut ends constructed from 19/38 (26AWG) Silver Plated Copper Wire with FEP insulation. Latch clips are provided to secure the connector to associated product.
-
A025CFR-T-5A200 -
Pickering Interfaces Ltd.
This 2m long female 25-Pin Micro-D to unterminated (with tinned ends) cable assembly is constructed from 18/0.1 (26 AWG) copper wiring with PVC insulation and screening to minimise crosstalk. Screwlocks are provided to secure the connector to its associated product.
-
A025CFR-T-5A050 -
Pickering Interfaces Ltd.
This 0.5m long female 25-Pin Micro-D to unterminated (with tinned ends) cable assembly is constructed from 18/0.1 (26 AWG) copper wiring with PVC insulation and screening to minimise crosstalk. Screwlocks are provided to secure the connector to its associated product.
-
A025CFR-C-5A200 -
Pickering Interfaces Ltd.
This 1m long female 25-Pin Micro-D to unterminated (with cut ends) cable assembly is constructed from 18/0.1 (26 AWG) copper wiring with PVC insulation and screening to minimise crosstalk. Screwlocks are provided to secure the connector to its associated product.
-
A025CFR-T-5A100 -
Pickering Interfaces Ltd.
This 1m long female 25-Pin Micro-D to unterminated (with tinned ends) cable assembly is constructed from 18/0.1 (26 AWG) copper wiring with PVC insulation and screening to minimise crosstalk. Screwlocks are provided to secure the connector to its associated product.
-
A025CFR-C-5A050 -
Pickering Interfaces Ltd.
This 0.5m long female 25-Pin Micro-D to unterminated (with cut ends) cable assembly is constructed from 18/0.1 (26 AWG) copper wiring with PVC insulation and screening to minimise crosstalk. Screwlocks are provided to secure the connector to its associated product.
-
LXinstruments GmbH
Leakage current and discharge current depend on the insulation of the device. The measurement simulates various fault situations that could occur during operation. The test determines whether the measured current is within the permissible limits and poses no danger to the user in case of a fault.
-
LXinstruments GmbH
The hipot test (high potential test) or dielectric withstand test, is used to determine the insulation and dielectric strength. It is carried out on modules, devices and systems of protection class I + II. In this test, the insulation of the test object is subjected to greater stress by the high voltage than in normal operation. It is determined whether the insulation of all current-carrying conductors, as well as the safety distance to the enclosure, is sufficient and complies with the legal requirements under normal operating conditions.We will be happy to assist you with any questions or solutions to problems.You will find a large selection of high-voltage testers in our comprehensive shop.Questions? We are always at your disposal.
-
Power Diagnostix Systems GmbH
Partial discharge testing – well established for high voltage equipment – becomes increasingly important for insulation systems of a lower voltage level. Changing to switching power supply and to IGBT control of induction motors, for instance, raise demands and testing needs for the insulation system. The modular concept of Power Diagnostix’ instruments allows offering customized solutions for automated and semi-automated testing.
-
CZ20500 -
Aegis Pty. Ltd.
The CZ20500 Multi-Function electrical tester includes some of the latest advances in electrical testing, combining 5 instruments into 1! Insulation, Loop, Phase, RCD, and Voltage testing are all included in the one instrument, making your job of installation testing easier.
-
A025CFR-C-ZA180 -
Pickering Interfaces Ltd.
This economy 1.8m long female 25-Pin Micro-D to unterminated (with tinned ends) cable assembly is constructed from 7/36 (28 AWG) copper wiring with PVC insulation and screening to minimise crosstalk. Screwlocks are provided to secure the connector to its associated product.