Filter Results By:

Products

Applications

Manufacturers

Showing results: 1111 - 1125 of 1232 items found.

  • HV Test System for Patient Monitors

    LXinstruments GmbH

    HV test enclosure for testing medical products (patient monitors). Insulated test booth with large space for DUT.3 different test nests for adapting different devices.Displays from patient monitors are checked. For this, insulation tests and leakage current measurements must be carried out. Ensuring the standard-compliant test. For the safety of the operating personnel, the test cell is electrically locked while the high voltage measurement is active.

  • KPG 24kV VLF Test Set

    Kilovolt Prueftechnik Chemnitz GmbH

    The portable cable test set KPG 24kV VLF is used for testing of medium voltage cables in accordance to the standards IEC 60502-2, CENELEC HD 620 & 621, DIN VDE 0276/620 & 621 and IEEE 400.Test is carried out with a low strain practice with VLF (very low frequency) test voltage of preferably 0.1Hz.VLF testing enables detection of damages of insulation within shortest test time.

  • Measurement & Diagnostic Products

    DURST Motor & Electric Industries Pty Ltd.

    DURST Measurement & Diagnostic Products; circuit tester, vehicle battery analyzer, multimeter, dedicated automotive multimeter, clamp meter, sound level meter, oxygen sensor tester, diesel engine tachometer, multisystem ignition analyzer, faultfinder, circuit tester, diode tester, regulator tester, growler for testing motor insulation, armature/commutator tester, diagnostic testers, current clamps, optical photo/contact tachometer, etc.

  • Manual PAT Testers

    Seaward Electronic Ltd

    If you are looking for a manual PAT tester with a pass fail reading or a PAT tester with readings we have a solution for you. Carry out mains supply checks, IEC lead tests, Earth continuity tests at 200mA, Insulation resistance tests to 250V and 500V, and more with these popular testers. All of our manual PAT testers are available as kits to help you streamline the way you work.

  • Capacitors - Beam Lead

    Macom Technology Solutions Holdings Inc.

    MACOM’s MMI-9000 and 9100 Series Chip Capacitors feature high stand-off voltage and low dielectric loss leveraging nitride/oxide dielectric layers. Gold bonding surfaces, top and bottom provide ease of bonding and minimum contact resistance. MACOMs beam lead capacitors have high insulation resistance, low dissipation factor, and low temperature coefficient, which are features that produce devices with excellent long-term stability.

  • Test Sets For Transformer Industries

    NEO TELE-TRONIX PVT. LTD

    Contemporary Test Sets For Transformer Industries are developed to recognize the potentially disastrous current transformer errors. They prevent the primary current from overpowering insulation and short circuits. They are used for developing a testing and maintenance plan for addressing the errors before any failure to save money and time. With these powerful test sets, they are sure to perform saturation testing to test the knee point of a signal by comparing primary and secondary windings.

  • Cable Test Van

    ETL-35K - Kharkovenergopribor Ltd.

    ETL-35K system has a multitude of applications in electrical equipment testing and maintenance: testing cable insulation with DC (rectified) voltage up to 60 kV, measuring small leakage current of surge arrestors, high-voltage testing with AC voltage up to 100 kV at industrial frequency, underground utilities tracing, cable fault pre-location and pinpointing, and measuring capacitance and tan delta of various electrical objects at industrial frequency.

  • Guardian Hipot Tester AC/DC/IR/SCAN

    19050 - Chroma Systems Solutions, Inc.

    The Chroma Guardian 19050 series of Hipot Testers are comprised of three models. The Guardian 19052 is equipped for AC/DC/IR Hipot testing and insulation resistance (IR) measurements. The Guardian 19053 combines both AC and DC Hipot tests and IR measurements with 8HV scan channel capabilities. The Guardian 19054 combines both AC and DC Hipot tests and IR measurements with 4HV scan channel capabilities.

  • Power Inductor - Impulse Winding Tester

    19301A - Chroma Systems Solutions, Inc.

    The Chroma 19300 Impulse Winding Tester with high/low inductance test technology has 1000V of impulse voltage and a 200MHz high speed sampling rate that satisfies most power inductor test requirements for a wide range of inductance products from 0.1uH to 100uH. The built-in Area Size Comparison, Differential Area Comparison, FLUTTER value, and LAPLACIAN value functions are able to effectively inspect coils for insulation abnormalities.

  • *High Current Switches

    B-1002 - Ruetz Technologies GmbH

    Ross High Current Switches are available up to 36,000 amps continuous and over 1,700,000 amps 20µsec RC pulse, with voltage ratings of 6 volts to 400kV peak test. Standard Ross high current switches are built with 80 to 120psi air cylinder actuators. Air cylinder or motor operated for high contact force.  Arcing contacts optional for closing current. G-10 epoxy glass laminate is standard insulation on most models. G-7 silicone glass is used on models available for RF applications above 100kHz.  Most Ross high current switches are available with additional lengths of insulation, where the high voltage contacts need to be spaced at a greater distance from the actuator and control circuit.  Voltage withstand value is at least doubled and the interrupt capability is much greater when high current switches are immersed in insulating oil, fluid or SF6 gas.  For gas atmosphere, no modifications are necessary; however, oil or fluid immersion requires modification at a slight extra cost.

  • High Current Switches

    B-1002 - ROSS ENGINEERING CORPORATION

    Ross High Current Switches are available up to 36,000 amps continuous and over 1,700,000 amps 20µsec RC pulse, with voltage ratings of 6 volts to 400kV peak test. Standard Ross high current switches are built with 80 to 120psi air cylinder actuators. Air cylinder or motor operated for high contact force.  Arcing contacts optional for closing current. G-10 epoxy glass laminate is standard insulation on most models. G-7 silicone glass is used on models available for RF applications above 100kHz.  Most Ross high current switches are available with additional lengths of insulation, where the high voltage contacts need to be spaced at a greater distance from the actuator and control circuit.  Voltage withstand value is at least doubled and the interrupt capability is much greater when high current switches are immersed in insulating oil, fluid or SF6 gas.  For gas atmosphere, no modifications are necessary; however, oil or fluid immersion requires modification at a slight extra cost.

  • DC Resistance or Conductance of Insulating Materials

    ASTM D257 - National Technical Systems

    These test methods cover direct-current procedures for the measurement of dc insulation resistance,volume resistance, and surface resistance. From such measurements and the geometric dimensions of specimen and electrodes, both volume and surface resistivity of electrical insulating materials can be calculated, as well as the corresponding conductances and conductivities. These test methods are not suitable for use in measuring the electrical resistance/conductance of moderately conductive materials. Use Test Method D4496 to evaluate such materials. This standard describes several general alternative methodologies for measuring resistance (or conductance). Specific materials can be tested most appropriately by using standard ASTM test methods applicable to the specific material that define both voltage stress limits and finite electrification times as well as specimen configuration and electrode geometry. These individual specific test methodologies would be better able to define the precision and bias for the determination.

  • Passive Component ATS

    Chroma ATE Inc.

    Test and packing speeds from 80ppm to1,800ppmStandard functions - Inductance/quality factor test - Winding resistance test - Polarity testOptional functions - Layer short test - Insulation resistance test - Bias current testCircular vibrating plate design feeds inductors steadily and rapidlyIndex disc design eliminates dropped inductorsFour-wire measurement test socket designAutomatic discharge mechanism when feeding errors occurEach test station has an independent NG (No Good) product collection boxTest without packaging function provided, good products gathered in bulk collection boxExclusive data collection software designed for monitoring product quality in real timeReserved stations for number spraying and automatic optical inspectionSwitchable Chinese/English/Japanese operating interfaceEquipment is fast, stable and safe

  • Solar Connectors & Adapters

    TE Connectivity Ltd.

    Our SOLARLOK photovoltaic connectors are designed for easy, quick and reliable DC connections for solar technology. With a precision-engineered design, these help achieve the lowest contact resistance to reduce power losses. Our DC Plug and splice connectors provide reliable connection, reducing up to 80% installation time with Insulation Displacement Contact (IDC) technology. Our grounding connectors enable installers to ground the photovoltaic system and create flexibility at the installation.

  • Battery Cell Surge Tester

    19311 - Chroma ATE Inc.

    The Chroma 19311 series battery cell surge tester is designed for testing the insulation quality between the positive and negative plates of the lead-acid battery cell. This is done by applying a high voltage surge/impulse before the electrolyte injection. Its output voltage can reach up to 6kV. It also has four terminal measurement and 200MHz sampling rate. The Chroma 19311 series has single channel (19311) and multi-channel (19311-10) tester.

Get Help