Filter Results By:

Products

Applications

Manufacturers

Showing results: 1096 - 1110 of 1149 items found.

  • JTAG USB Controller

    NetUSB-1149.1/E - Corelis, Inc.

    The NetUSB-1149.1/E (4 TAPs) is an advanced USB 2.0 and LAN-based controller that can be used in the testing and/or in-system programming (ISP) of devices, boards, or systems compliant with the IEEE-1149.1 standard. The NetUSB-1149.1/E controller supports concurrent (gang) testing and in-system programming of CPLDs and Flash devices at TCK rates of up to 80MHz.The controller connects to the computer either through the USB interface or LAN interface for easy installation at nearby or remote locations. Other features include signal delay compensation for long cable lengths to the UUT, TAP signals, and GPIO discrete signals which are individually programmable from 1.25V to 3.3V, programmable slew rate control and pre-power up test for shorts between power and ground traces on the UUT.

  • Field Portable NIR Spectrometers For Mineral Identification And Analysis In Mining Exploration

    Spectral Evolution Inc.

    With Spectral Evolution field portable NIR spectrometers and EZ-ID mineral identification software, geologists can measure and identify minerals within seconds and cover more ground than by using traditional methods. They can identify different mineral phases, create mineral alteration maps and more accurately identify mineral pathfinders for vectoring to ore deposits. Spectral Evolution's field portable, battery-operated oreXpress, oreXplorer and oreXpert ultra-high resolution NIR spectrometers are designed for mineral identification in mining exploration. The oreXpress, oreXplorer and oreXpert provide quick payback with faster, more accurate mineral identification in exploration for gold, silver, diamonds, iron, nickel, copper, uranium, aluminum - in the field, core shack, or in the lab, and provide:

  • Wristat Tester

    WT 25-4145.26M - Walter G. Legge Company Inc.

    WT 25-4145.26M Wristat Tester is available to comply with D.O.D. 4145.26 specifications. The WT25-4145.26M Wristat Tester is designed to test the integrity of our WRISTAT in a fast, efficient, and simple manner. All the elements of the WRISTAT – continuity of the strap, integrity of the protective resistor, and satisfactory strap to skin contact – are easily confirmed by pressing the top cover of the WT25-4145.26M. The operator (wearer) is tested for a resistance to ground of greater than 250K ohms and less than1,200,000 ohms. The upper limit notifies you of an unacceptably high resistance value (IE possible loss of effective dissipation) and the lower limit warns of unsafe low resistance (possible risk of electric shock from surrounding motors, live wires etc.). The unit is not switchable.

  • NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module

    783864-02 - NI

    8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module

    785189-01 - NI

    8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module

    785186-01 - NI

    8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module

    783863-01 - NI

    8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • NI-9217, 4-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module

    779592-01 - NI

    4-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9217 is a resistance temperature detector (RTD) input module. You can configure the NI‑9217 for two sample rate modes: high sample rate or high resolution. The NI‑9217 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9217 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • NI-9205, ±10 V, 250 kS/s, 16-Bit, 32-Channel C Series Voltage Input Module

    779357-01 - NI

    ±10 V, 250 kS/s, 16-Bit, 32-Channel C Series Voltage Input Module - The NI‑9205 performs single-ended or differential analog inputs, with four programmable input ranges for each. It is an effective combination of channel count and speed at a low price for an economical multifunction system. You can choose from four programmable input ranges. To protect against signal transients, the NI‑9205 includes up to 60 V of overvoltage protection between input channels and common. In addition, the NI‑9205 also includes a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. It is rated for 1,000 Vrms transient overvoltage protection.

  • NI-9205, ±10 V, 250 kS/s, 16-Bit, 32-Channel C Series Voltage Input Module

    780173-01 - NI

    ±10 V, 250 kS/s, 16-Bit, 32-Channel C Series Voltage Input Module - The NI‑9205 performs single-ended or differential analog inputs, with four programmable input ranges for each. It is an effective combination of channel count and speed at a low price for an economical multifunction system. You can choose from four programmable input ranges. To protect against signal transients, the NI‑9205 includes up to 60 V of overvoltage protection between input channels and common. In addition, the NI‑9205 also includes a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. It is rated for 1,000 Vrms transient overvoltage protection.

  • NI-9205, ±10 V, 250 kS/s, 16-Bit, 32-Channel C Series Voltage Input Module

    785184-01 - NI

    ±10 V, 250 kS/s, 16-Bit, 32-Channel C Series Voltage Input Module - The NI‑9205 performs single-ended or differential analog inputs, with four programmable input ranges for each. It is an effective combination of channel count and speed at a low price for an economical multifunction system. You can choose from four programmable input ranges. To protect against signal transients, the NI‑9205 includes up to 60 V of overvoltage protection between input channels and common. In addition, the NI‑9205 also includes a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. It is rated for 1,000 Vrms transient overvoltage protection.

  • NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module

    783864-01 - NI

    8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module

    783863-02 - NI

    8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • PXI Signal Insertion Switch Module

    NI

    PXI Signal Insertion Switch Modules, also known as fault insertion units (FIUs), provide a set of feedthrough channels, which make the switch transparent to the system when closed. You can open or short these channels to one of two fault buses, allowing you to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI Signal Insertion Switch Module can validate the integrity of control systems including engine control units (ECUs) and full authority digital engine controls (FADECs). You can also use the FIU models for hardware-in-the-loop (HIL) applications and electronic reliability tests.

  • Surface Resistance System Kit

    PRS-801RM - Prostat Corporation

    - Perform Point-to-Point and Resistance to Ground Measurements from 0.01 Ω to 200 Teraohms- Accuracy of ±2% from 1.00 Ω to 9.99x1010Ω- Measures in accordance with ESD TR53, ANSI/ESD S4.1, ANSI/ESD S7.1, ANSI/ESD STM97.1 and others- Constant Test voltages 10V and 100V meeting ANSI/ESD S20.20- Operates using a Rechargeable Li-ion Battery Pack- Takes Approximately 8,000 Measurements on a Single Charge (480 hours typical)- Stores up to 999 Test Values Into Memory- Compatible with Prostat Connect 2.0 for Downloading into Excel®- Charging and Download via Standard Micro USB Cable- Includes 5lb Conductive Probes and Carrying Case- Certificate of Calibration Traceable to NIST included- 2-year Limited Warranty on Main Instrument

Get Help