Filter Results By:

Products

Applications

Manufacturers

Showing results: 1111 - 1125 of 1151 items found.

  • PXI Signal Insertion Switch Module

    NI

    PXI Signal Insertion Switch Modules, also known as fault insertion units (FIUs), provide a set of feedthrough channels, which make the switch transparent to the system when closed. You can open or short these channels to one of two fault buses, allowing you to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI Signal Insertion Switch Module can validate the integrity of control systems including engine control units (ECUs) and full authority digital engine controls (FADECs). You can also use the FIU models for hardware-in-the-loop (HIL) applications and electronic reliability tests.

  • Surface Resistance System Kit

    PRS-801RM - Prostat Corporation

    - Perform Point-to-Point and Resistance to Ground Measurements from 0.01 Ω to 200 Teraohms- Accuracy of ±2% from 1.00 Ω to 9.99x1010Ω- Measures in accordance with ESD TR53, ANSI/ESD S4.1, ANSI/ESD S7.1, ANSI/ESD STM97.1 and others- Constant Test voltages 10V and 100V meeting ANSI/ESD S20.20- Operates using a Rechargeable Li-ion Battery Pack- Takes Approximately 8,000 Measurements on a Single Charge (480 hours typical)- Stores up to 999 Test Values Into Memory- Compatible with Prostat Connect 2.0 for Downloading into Excel®- Charging and Download via Standard Micro USB Cable- Includes 5lb Conductive Probes and Carrying Case- Certificate of Calibration Traceable to NIST included- 2-year Limited Warranty on Main Instrument

  • Telemetry Receivers

    2U R200A Series - Systems Engineering & Management

    R200A Series Receivers are designed for fixed and mobile Telemetry Ground Stations, but particularly for mobile applications where space is at a premium. The R200A provides for many of the same configurations and options available with the larger R600A and R400 systems, using the same cards, modules and RCMS network software for optimum interoperability. In addition, the RT200 Tracking Receiver configurations are an extremely popular, low cost solution for antenna tracking installations. The R200A provides the same proven performance and reliability and user interface of the R600A and R400. Like the R600A and R400, a "non-PC" configuration is available for remote operation via Ethernet. The 2U R200A receiver has become one of SEMCO's most popular receivers in terms of small form factor and operational performance and reliability.

  • Stand Alone/ Bench Top Load Cell Amplifier/ Conditioner Module

    MODEL TMO-2A - Transducer Techniques, Inc

    The TMO-2A Transducer Modules is a complete differential amplifier/signal conditioners with self contained power. The unit provide excitation, balance and span adjustment via precision 10 turn pots, and shunt calibration necessary to couple a user supplied bridge type transducer to an indicating instrument. Zero to full scale output is specified at 4-20 mA. The TMO-2A provides a floating shunt calibration circuit which applies calibration at the transducer, thereby eliminating errors due to line losses. The excitation supply incorporates a Wagner Ground to greatly improve Common Mode Rejection. The factory set bandwidth of the module is narrow to improve stability. The removal of a single capacitor will increase the frequency response DC to 60K Hz for dynamic data applications.

  • High Voltage Surge Testers

    HVST - Test Electronics

    The most important features of the surge tester are its ability to test the entire winding insulation system. A high voltage surge generates turn to turn, coil to coil, and phase to phase voltage stress, as well as ground insulation stress. When used as a dielectric test, accurate voltage readings are essential. The HV Surge Tester monitors the voltage directly across the winding under test. This voltage is displayed on an oscilloscope and recorded on the Pass/ Fail LED latch monitor. This voltage will be accurate despite the impedance of the winding being tested. The insulation system can be tested way above the operating voltage because of the brief duration of the applied voltage test pulse. This allows faults to be detected long before they become apparent at operating conditions.

  • sbRIO-9205, Non-Enclosed, ±10 V, 250 kS/s, 16-Bit, 32-Channel C Series Voltage Input Module

    784787-01 - NI

    Non-Enclosed, ±10 V, 250 kS/s, 16-Bit, 32-Channel C Series Voltage Input Module - The sbRIO‑9205 performs single-ended or differential analog inputs, with four programmable input ranges for each. It is an effective combination of channel count and speed at a low price for an economical multifunction system. You can choose from four programmable input ranges. To protect against signal transients, the sbRIO‑9205 includes up to 60 V of overvoltage protection between input channels and common (COM). In addition, the sbRIO‑9205 also includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. It is rated for 1,000 Vrms transient overvoltage protection. Non-enclosed modules are designed for OEM applications.

  • High Resolution MWIR Camera Modules

    Neutrino® Performance Series - Teledyne FLIR

    The performance series includes the FLIR Neutrino QX and SX12. Neutrino SX12 is a 1280×1024/12 µm resolution focal plane array (FPA) and has a frame rate of 120 Hz at 720P and >60 Hz for SXGA. Neutrino QX is a 2048×1536/10 µm FPA and has a frame rate of 60 Hz at 1080P and >30 Hz for QXGA. Neutrino Performance Series is ideal for ground or airborne intelligence, surveillance and reconnaissance (ISR), targeting, counter-UAS solutions and Wide Area Motion Imagery (WAMI) applications. The industry-standard interfaces, simple and powerful software controls, complete product documentation and Teledyne FLIR technical support reduces product development risk and shortens time to market. The Neutrino is an OEM camera module that is intended to be integrated into a higher level system.

  • Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 4 Channel

    40-201-004 - Pickering Interfaces Ltd.

    This high bandwidth differential fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.

  • Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 8 Channel

    40-201-008 - Pickering Interfaces Ltd.

    This high bandwidth differential PXI fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.

  • Motor Winding Ohmmeter

    RMO-M Series - IBEKO Power AB

    The motor/generator winding resistance test is used to identify open windings, shorts between two windings, short to grounds, connection mistakes or shorted turns. This non-invasive test of winding resistance helps to pinpoint problems regarding windings in stator or rotor part of an electrical machine. Additionally, motor winding ohmmeter has the capability of performing heat run test which will show a change in windings resistance with an increase of temperature.The RMO-M series is designed as an ideal aid in preventive maintenance of electrical motors and generators. They are powerful (up to 100A of test current), portable (8 kg) and generate DC current which is completely ripple-free. This makes measurement very precise with 0,1% accuracy.Three voltage channels make measurement very easy since it is possible to obtain a value of all three winding resistances in one measurement

  • Universal Multichannel System up to 8 kV

    CAEN S.p.A.

    - From 12 to 24 independently controllable High Voltage channels- 8 kV maximum output voltage- Maximum Current 1 mA- Either Radiall Multipin or SHV connectors- Available with either positive or negative polarity- Up to 500 pA/50 pA current set / monitor resolution- Up to 100 mV/10 mV voltage set / monitor resolution- Very Low ripple, down to < 5 mV- 3 different channel grounding - Common Ground (AGxxxx) - Common Floating Return (Axxxx) - Individual Floating (A1534 only)- Independently programmable for each channel: - Output voltage - Current limit - Ramp up/down (1 ÷ 500 V/sec) - TRIP parameter- Current generator operation in overcurrent condition- Specific design for Germanium detectors (A15x0H only)

  • C Series Current Output Module

    NI

    The C Series Current Output Module features up to eight channels of simultaneous analog output. You can choose between enclosed and non-enclosed modules. Additionally, the C Series Current Output Module has built-in open-loop detection. This detection generates an interrupt in software when an open loop is detected, zeros outputs to ensure safety, and avoids driving actuators at system power-on. The C Series Current Output Module requires an external power supply and includes a channel-to-earth ground double isolation barrier for safety and noise immunity.The C Series Current Output Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.

  • Situational Understanding Mission Intelligent Technology

    SUMIT360™ - Teledyne FLIR

    The SUMIT360™ provides military armored vehicle operators with an innovative, 360 degree view of the environment around the vehicle utilizing advanced sensor technology to improve threat and obstacle detection that could pose a threat to ground forces, and their mission. Equipped with powerful multi-spectral sensors in each module, the system uses on-board processing to form seamless, stitched images to provide a full field of view in any terrain, and virtually any conditions, day or night. With additional target detection and identification capability, the system can also be paired with advanced analytics and Artificial Intelligence (AI) to provide vehicle crew, and transported troops a threat detection and classification to provide critical decision support before opening the hatch. The system also provides the ability to support remote or optionally manned configurations.

  • Stand Alone/ Bench Top Load Cell Amplifier/ Conditioner Module

    MODEL TMO-2 - Transducer Techniques, Inc

    The TMO-2 Transducer Modules is a complete differential amplifier/signal conditioners with self contained power. The units provide excitation, balance and span adjustment via precision 10 turn pots, and shunt calibration necessary to couple a user supplied bridge type transducer to an indicating instrument. Full scale output is specified at plus or minus 10 VDC. The TMO-2 provides a floating shunt calibration circuit which applies calibration at the transducer, thereby eliminating errors due to line losses. The excitation supply incorporates a Wagner Ground to greatly improve Common Mode Rejection. The factory set bandwidth of the module is narrow to improve stability for applications such as weighing scales. The removal of a single capacitor will increase the frequency response DC to 60K Hz for dynamic data applications.

  • 2 in 1 LAN Tester

    PLTM20 - Pyle Audio Inc.

    Tests Pin Configuration for 10 Base-T, 10 Base-2, RJ45/RJ11, 356A, TIA-569A/568B and Token Ring CableRemotely Test Cables Up to 330 Yards AwayTest Ground WireMeasure DC/AC Voltage, DC/AC Current, Resistance, Continuity, and DiodeDC Voltage: Max Range 600 V, Accuracy +/- 0.5%AC Voltage: Max Range 600 V, Accuracy +/- 1.2%DC Current: Max Range 200 mA, Accuracy +/- 1.2%AC Current: Max Range 200 mA, Accuracy +/- 2.0%Resistance: Max Range 20 M, Accuracy +/- 0.8%Continuity Test: Beeps If Less Than 100 Accessories Included: Test Leads, LANtest Remote Terminator, 9V Battery, Carrying CaseDimensions: 6.38' H x 2.93' W x 1.73' DWeight: 10.86 oz.Sold as : Unit

Get Help