Filter Results By:

Products

Applications

Manufacturers

Showing results: 916 - 930 of 1151 items found.

  • Digital I/O Board, 64 Optically Isolated I/O Channels, 24V

    APCI-1564 - TEAM SOLUTIONS, INC.

    32 bit, 33 MHz, PCI interfaceInput channels32 isolated digital input channels, 24 V, incl. 16 interruptible and 3 fast counter inputsInput channels organised in 4 groups of 8 channels, each group has its own ground lineVoltage reversal protectionAll inputs are filteredOutput channels32 isolated digital output channels, 10 to 36 VOutput current per channel 500 mAWatchdog for resetting the outputs to "0"After power/ON the outputs are reset to ì0îShort-circuit current for 16 outputs ~ 3 AShort-circuit current for 32 outputs ~ 6 AShort-circuit current per output ~1.5 AElectronic fuseOvertemperature and overvoltage protection24 V power outputs with protection diodes and filtersSpecial output capacitors minimise electromagnetic emissionsExternal 24 V supply screened through a protection circuitryShutdown logic when the external supply voltage drops unter 5 V

  • Universal Multichannel System up to 100V

    CAEN S.p.A.

    - From 12 to 48 independently controllable High Voltage channels- 0 ÷ 100 V output voltage- Maximum Current: 1mA, 10 mA or 1 mA/100 μA (dual range board)- Individual Enable (A1510 only)- Either DB37, DB25 or SHV connectors- Available with either positive, negative or mixed polarity- Up to 20 nA / 100 pA current set / monitor resolution- Up to 2 / 0.2 mV voltage set / monitor resolution- Extreme Low ripple, down to < 3 mVpp- 3 different channel grounding- Common Ground (AGxxxx)- Common Floating Return (Axxxx)- Full Floating (A1510 only)- Independently programmable for each channel:- Output voltage- Current limit- Ramp up/down- TRIP parameter- Current generator operation in overcurrent condition- Specific design for double side silicon detector (A1510)

  • The Mag Lead

    136 - Electronic Specialties Inc.

    *Mag Lead features a magnetic disconnect near the test probe end. *Just disconnect the test probe and you can “stick” to any metallic ground or test point. *Quit fumbling with alligator clips that fall off - Mag Lead’s powerfull magnet will hold tight! *This is a time saving tool - if you don’t have to walk to your tool box to retrieve your alligator clips, even on just half the occasions, then you’ve saved time. *Very helpful for automotive reference points and troubleshooting. *Can eliminate the need to hold probes while checking or monitoring a signal. *Two high power, low resistance magnets hold the probe to the lead. *Fits almost all Digital Multimeters and can be used with hand-held scopes too. *Get the Mag Lead, it stays put and won’t fall off, like alligator clips do!

  • Digital Earth Resistance Tester

    ERT-1501 - Neutronics Manufacturing Co.

    Electronic Digital Earth Resistance Tester is direct replacement of the conventional hand generator type tester. It is designed for measurement of the resistance of earthing used in the electrical equipment as well as for measurement of ground resistivity. It can be used for measurements of the other low regular and liquid resistances. It can also be used for measurement of voltage AC, voltage DC and resistance. This instrument finds wide application for testing earthing installation in power based industries, telecommunication networks and electrical traction systems etc.

  • Neutral Grounding Resistors

    Post Glover

    The main purpose of a Neutral Grounding Resistor (NGR) is to limit the fault current present in a single line to ground fault. Limiting the possible current that can flow in such an event not only reduces damage to equipment but also helps safeguard personnel in the vicinity. Depending on the design of the resistor, this current value can be either high or low, continuous or of a predetermined duration. The resistor’s designed maximum current allows relays and protection settings to be easily determined and enacted, creating a safe work environment.

  • RS-232 and RS-562 Transceivers

    Analog Devices Inc.

    Analog Devices offers single, dual, and combination transceivers of up to five RS-232/RS-562 drivers and receivers for 1.8 V to 5.5 V power supplies. Data terminal equipment (DTE) or data communications equipment (DCE) configurations are also available in 3.3 V or 5 V versions. Galvanically isolated modules break ground loops and provide a convenient, self-powered, isolated, low EMI solution that drastically reduces component count and design complexity.

  • Digital Audio Snake System

    OmniSnake - En Technology

    The OmniSnake consists of a Stage Box that converts microphone/line-level analog inputs to a multiplexed digital signal, and a companion Base Unit that de-multiplexes to provide individual outputs. Digitizing the analog audio at the source eliminates the potential for ground loops, noise interference and crosstalk. Each Stage Box has 8 inputs, and two Stage Boxes can be linked together via coax to form a combined 16 channels, which is carried over coaxial cable to the Base Unit.

  • Reactor Loss Measurement Systems

    Measurements International Ltd.

    The Shunt Reactor Loss Measurement System is a microprocessor controlled, metrology based, high voltage Capacitance, Inductance and Reactor Loss Measurement bridge which is based on the two stage- compensated current transformer. The 7010C bridge can be ordered by itself or it can be ordered with high voltage capacitors up to 800 kV line to ground and two-stage-compensated current transformers up to 4000A. the system is fully automatic displaying the rms voltage at the top of the capacitor, the reactor current and the reactor losses.

  • Isolation Amplifier

    Dr. Hubert GmbH

    Isolation amplifiers are indispensable components for signal conditioning. There are several reasons that make galvanic potential isolation necessary. Examples for this are personal protection, on the one hand, as required in medical engineering to ensure contact of persons with life-threatening voltages. On the other hand, different safety aspects, such as protection of IT systems may require the use of an isolation amplifiers. If ground loops need to be separated or if a small differential voltage with a high common-mode level must be determined, the isolation amplifier is the device of your choice.

  • Voltage Testers

    Morris Products Inc.

    Electrical Receptacle Tester Instantly Displays Wiring Condition of Any Standard 3-Wire AC 110-120 OutletNeon Indicators Give Positive Indication of Current StatusCompact Unit Simply Plugs into any Standard 3 Wire/Grounded Receptacle (110–125 Volt AC Circuits)Tests for 6 Circuit Conditions: Open Ground, Open Neutral, Open Hot, Hot/Ground Reverse, Hot/Neutral Reverse & Correct WiringBlister PackedcULus ListedOrder Qty of 1 = 1 Piece

  • NI-9265, 4-Channel C Series Current Output Module

    779334-01 - NI

    4-Channel C Series Current Output Module - The NI‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing … outputs to ensure safety and avoid driving actuators at system power on. The NI‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.

  • NI-9265, 4-Channel C Series Current Output Module

    783733-01 - NI

    4-Channel C Series Current Output Module - The NI‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.

  • NI-9265, 4-Channel C Series Current Output Module

    779334-02 - NI

    4-Channel C Series Current Output Module - The NI‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.

  • sbRIO-9263 , Non-Enclosed, 100 kS/s/ch Simultaneous, ±10 V, 4-Channel C Series Voltage Output Module

    780876-01 - NI

    Non-Enclosed, 100 kS/s/ch Simultaneous, ±10 V, 4-Channel C Series Voltage Output Module - The sbRIO‑9263 is a simultaneously updating analog output module. It features overvoltage protection, short-circuit protection, low crosstalk, fast slew rate, high relative accuracy, and NIST‑traceable calibration. The sbRIO‑9263 module includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity. Non-enclosed modules are designed for OEM applications.

  • PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel

    42-203-001 - Pickering Interfaces Ltd.

    The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.

Get Help