  • Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 4 Channel

    50-201-004 - Pickering Interfaces Ltd.

    This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, Broad R-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.

  • Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 8 Channel

    50-201-008 - Pickering Interfaces Ltd.

    This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.

  • Cassegrain Antennas

    ERAVANT

    In telecommunications and radar, a Cassegrain antenna is a parabolic antenna in which the feed antenna is mounted at or behind the surface of the concave main parabolic reflector dish and is aimed at a smaller convex secondary reflector suspended in front of the primary reflector. The beam of radio waves from the feed illuminates the secondary reflector, which reflects it back to the main reflector dish, which reflects it forward again to form the desired beam. The Cassegrain design is widely used in parabolic antennas, particularly in large antennas such as those in satellite ground stations, radio telescopes, and communication satellites.

  • Bluetooth Enabled Signal Conditioners I/O Modules

    microBlox - Acromag, Inc.

    Acromag's microBlox uB Series I/O modules offer a compact, high-performance solution for interfacing sensors and field devices with data acquisition systems. uB signal conditioning modules are ideal to isolate, filter, convert and amplify a wide variety of signal types for test, measurement and control systems. Just plug uB modules into 4, 8, or 16-channel backpanels in any mix for a high-density analog I/O interface. Channel-to-channel isolation provides optimal noise and surge protection from ground loops, spikes, and high common mode voltages.

  • PXI BRIC8 FIBO Matrix Dual 248x4 2pin Brkout

    40-592A-118 - Pickering Interfaces Ltd.

    The 40-592A FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units. Typical faults that can be simulated are open-circuits, short circuits to ground or battery, or short-circuits between input/output lines. Typical applications are in automotive and aerospace industries which involve safety or mission critical systems that have to behave predictably when cabling or sensor faults occur.

  • PXI BRIC4 FIBO Matrix Dual 124x4 2pin Brkout

    40-592A-014 - Pickering Interfaces Ltd.

    The 40-592A FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units. Typical faults that can be simulated are open-circuits, short circuits to ground or battery, or short-circuits between input/output lines. Typical applications are in automotive and aerospace industries which involve safety or mission critical systems that have to behave predictably when cabling or sensor faults occur.

  • PXI/PXIe Battery Simulator Module, 6-Channel, 1 KV Isolation

    41-752A-101 - Pickering Interfaces Ltd.

    Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 6-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture. The 750 V or 1 kV isolation barrier (version dependent) allows the module to be used as a lower power version of a battery stack, representative of those used for vehicle propulsion.

  • AC Line Splitter

    Extech 480172 - Extech Instruments Corporation

    This Extech 480172 Line Splitter provides a fast and easy way to “open” standard 120 Volt AC electrical lines, eliminating the need to cut off the plug and separate the conductors. When connected between a 120 Volt AC outlet and a device under test, this splitter separates the hot/live conductor from the neutral and ground, which enables users to measure AC current up to 15 Amp on a two-wire or three-wire lines using a clamp meter. This splitter also features two Voltage Test jacks so that voltage can be measured using a multimeter.

  • HIPOT Insulation Testers

    Laycock Systems

    Crown high voltage, transformer type hipot insulation testers are safe, easy to use for quick, positive determination of grounds, shorts, and broken wires in motors, transformers and other low voltage equipment or wiring systems. A turn of the selector switch gives a selection of seven voltages; 500, 1080, 1250, 1500, 1750, 2000 or 2500 volts calibrated to +/- 5% accuracy; NEMA recommendation for insulation test is twice normal voltage plus 1000 volts. Since this instrument has a capacity of 2500 volts, it readily accommodates all normal requirements.

  • High Resistance Neutral Grounding Devices

    Hilkar

    HRG systems limit the fault current by placing high resistance between neutral point of transformer (or generator) and ground. As it is not possible to locate the fault point in delta connected systems, an artificial neutral point is created and delta connected system can be grounded. This allows a fault current of a few amperes thus locating the fault point gets easy. When the neutral point is grounded thru high resistance, both continuity of operation is provided during fault condition and sufficient current (typically between 2 A and 10 A) flow is provided for ease of locating the fault point.

  • Laser Hunter - gas detection & gas measurement device

    Esders GmbH

    Highly sensitive and selective gas detection & gas measurement device withlaser technology for the inspection of underground gas pipes using suitableprobes (e. g. carpet probe). The device can also be used for the vehicle-basedpipeline inspection.With built-in diaphragm pump, Bluetooth module and rechargeable Li-Ion battery.The following applications are possible:- Inspection of underground pipes- Inspection of accessible pipes in buildings- Inspection of accessible pipes on plants, etc.- Inspection of ground soil for pinpointing (optional)- Purging of gas pipelines (optional, only in combination with pinpointing)- Gas analysis (with dual laser module)

  • NI-9206, ±10 V, 250 kS/s, 16-Bit, 32-Channel, 60 VDC Isolation C Series Voltage Input Module

    779526-01 - NI

    ±10 V, 250 kS/s, 16-Bit, 32-Channel, 60 VDC Isolation C Series Voltage Input Module - The NI‑9206 performs differential analog input with four programmable input ranges. The module provides up to 600 VDC (400 VDC in Europe) channel‑to‑earth ground isolation, making the module ideal for accurately monitoring large fuel cell and battery stacks. By referencing the module common (COM) to the middle of the NI‑9206 bank, you can measure 16 consecutive cells and remain within 10 V of the module COM.

  • NI-9229, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module

    780180-01 - NI

    ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module - The NI‑9229 performs differential analog input. The NI‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating.

  • NI-9229, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module

    779785-01 - NI

    ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module - The NI‑9229 performs differential analog input. The NI‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating.

  • NI-9229, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module

    779785-02 - NI

    ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module - The NI‑9229 performs differential analog input. The NI‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating.