Filter Results By:

Products

Applications

Manufacturers

Showing results: 1021 - 1035 of 1156 items found.

  • Laser Hunter - gas detection & gas measurement device

    Esders GmbH

    Highly sensitive and selective gas detection & gas measurement device withlaser technology for the inspection of underground gas pipes using suitableprobes (e. g. carpet probe). The device can also be used for the vehicle-basedpipeline inspection.With built-in diaphragm pump, Bluetooth module and rechargeable Li-Ion battery.The following applications are possible:- Inspection of underground pipes- Inspection of accessible pipes in buildings- Inspection of accessible pipes on plants, etc.- Inspection of ground soil for pinpointing (optional)- Purging of gas pipelines (optional, only in combination with pinpointing)- Gas analysis (with dual laser module)

  • NI-9206, ±10 V, 250 kS/s, 16-Bit, 32-Channel, 60 VDC Isolation C Series Voltage Input Module

    779526-01 - NI

    ±10 V, 250 kS/s, 16-Bit, 32-Channel, 60 VDC Isolation C Series Voltage Input Module - The NI‑9206 performs differential analog input with four programmable input ranges. The module provides up to 600 VDC (400 VDC in Europe) channel‑to‑earth ground isolation, making the module ideal for accurately monitoring large fuel cell and battery stacks. By referencing the module common (COM) to the middle of the NI‑9206 bank, you can measure 16 consecutive cells and remain within 10 V of the module COM.

  • NI-9229, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module

    780180-01 - NI

    ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module - The NI‑9229 performs differential analog input. The NI‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating.

  • NI-9229, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module

    779785-01 - NI

    ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module - The NI‑9229 performs differential analog input. The NI‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating.

  • NI-9229, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module

    779785-02 - NI

    ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module - The NI‑9229 performs differential analog input. The NI‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating.

  • PXI/PXIe 1000Base-T1 Dual Multiplexer With Fault Insertion, Dual Channel

    40-204-002 - Pickering Interfaces Ltd.

    The 40-204-002 (PXI) and 42-204-002 (PXIe) are dual channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault. Using the fault bus, switches can simulate a short between both wires or a short to one of two externally applied fault conditions – such as battery supply or ground - via two fault buses.

  • PXI Matrix Switch: 8x32, 1-Wire, 100Vrms/2A, Armature Relays

    M9122A - Keysight Technologies

    The M9122A is an 8x32 full crosspoint switch matrix offering high-voltage switching in a high-density PXI module. This module allows for higher voltage switching of multiple channels in a single instance. Any row can be connected to any column, making it ideal for routing instrument signals to the device under test. This module is configured with a common ground. The durable armature switches are capable of switching up to 100Vrms, with up to 60W of power. The 8-wide bus can be used to route signals between your instruments and the device under test. Choose from the durable connector block or standard cable connections.

  • sbRIO-9213, Non-Enclosed, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module

    781210-01 - NI

    Non-Enclosed, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The sbRIO-9213 is a high-density thermocouple input module that is designed for higher-channel-count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The sbRIO-9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The sbRIO-9213 features NIST-traceable calibration and a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.

  • NI-9225, 300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module

    780159-01 - NI

    300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module - The NI‑9225 performs differential analog input. The wide measurement range is well suited for high-voltage measurement applications such as power metering, power quality monitoring, motor test, battery stack testing, and fuel cell tests. You can perform transient and harmonic analysis with high-speed simultaneous sampling. In addition, you can prevent ground loops and add safety to a system with 600 Vrms channel‑to‑channel isolation between the three NI‑9225 channels.

  • sbRIO-9264, Non-Enclosed, 25 kS/s/ch Simultaneous, ±10 V, 16-Channel C Series Voltage Output Module

    781119-01 - NI

    Non-Enclosed, 25 kS/s/ch Simultaneous, ±10 V, 16-Channel C Series Voltage Output Module - The sbRIO‑9264 is a simultaneously updating analog output module that accommodates higher‑channel‑count systems. Higher density modules conserve chassis space, which leaves room for other measurement types. Each channel has its own digital‑to‑analog converter. The spring-terminal version of the sbRIO‑9264 uses a 36‑position connector for the output channels, and each channel has a ground connection. Non-enclosed modules are designed for OEM applications.

  • NI-9225, 300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module

    780159-02 - NI

    300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module - The NI‑9225 performs differential analog input. The wide measurement range is well suited for high-voltage measurement applications such as power metering, power quality monitoring, motor test, battery stack testing, and fuel cell tests. You can perform transient and harmonic analysis with high-speed simultaneous sampling. In addition, you can prevent ground loops and add safety to a system with 600 Vrms channel‑to‑channel isolation between the three NI‑9225 channels.

  • NI-9422, 24 V to 60 V, 8 Channel (Sinking/Sourcing Input), 250 µs C Series Digital Module

    779522-01 - NI

    24 V to 60 V, 8 Channel (Sinking/Sourcing Input), 250 µs C Series Digital Module - The NI‑9422 works with industrial logic levels and signals to directly connect to a wide array of industrial switches, transducers, and devices. Each channel accommodates 24 V to 60 V digital input signals. The NI‑9422 features channel‑to‑channel and channel‑to‑earth ground isolation for the highest level of safety for automotive and industrial environments The NI‑9422 is a correlated digital module, so it can perform correlated operations, triggering, and synchronization.

  • NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module

    785185-02 - NI

    16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.

  • NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module

    785185-01 - NI

    16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.

  • Automatic Oil Insulation Test Kit

    Sivananda Electronics

    The test kit is fully automatic and has the facility forAuto/Manual selections. The operator simply needs thesample in the test vessel & selects the required test. Testingcan be done as per many international ( IEC & Europeanstandards ) which are programmed into the instrumentmemory . Stand time, Stir times & Rate of rise of appliedvoltage can be selected in Custom Mode also , one setof such selected mode can also be stored in the memory. In addition to the above set can also perform withstand test(proof) tests. In this test the set allows the set voltage to pre-set value & hold for one minute to see if breakdown occurs. The backlit LCD is used for user friendly operationsduring the test process. It also display fault condition messages such as open ground and cover open . All the user selected programmes are chosen through(4x3) key pad.The test results can be printed along with with test type, date, time, breakdown test voltage, averages and deviations. Voltage value can be measured & printed with a resolution of 0.1kV. In reprint option it is possible to have number of printouts for the last test. For each test the readings are recorded and stored in memory.

Get Help