Filter Results By:

Products

Applications

Manufacturers

Showing results: 1066 - 1080 of 1149 items found.

  • Line Tester

    CAT 1 TEST - Monacor International GmbH & Co. KG

    Line tester for continuity testing of Cat 5, Cat 6 and ISDN network cables*Connection test with LED display for 8 individual wires and shielding*Continuity, miswire, open, short, crossover, and ground detection*Connector compatibility with the following modular plugs: RJ45 (8P8C), RJ12 (6P6C), RJ11(6P4C, 6P2C)*Network standards supported: Token Ring, 10Base-T, 10Base-T2, 285A, TIA568A/568B*Separate receiver for particularly long and complex cables*The main unit and separate receiver can be attached to one another using a guide rail on the side*Power supply via 9 V block battery (not included)*Supplied with protective bag

  • sbRIO-9225, Non-Enclosed, 300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module

    780588-01 - NI

    Non-Enclosed, 300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module - The sbRIO‑9225 performs differential analog input. The wide measurement range is well suited for high-voltage measurement applications such as power metering, power quality monitoring, motor test, battery stack testing, and fuel cell tests. You can perform transient and harmonic analysis with high-speed simultaneous sampling. In addition, you can prevent ground loops and add safety to a system with 600 Vrms channel‑to‑channel isolation between the three sbRIO‑9225 channels. Non-enclosed modules are designed for OEM applications.

  • PXI-2514, 7-Channel, 40 A PXI Signal Insertion Switch Module

    778572-14 - NI

    7-Channel, 40 A PXI Signal Insertion Switch Module—The PXI‑2514 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2514 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls

  • PXI-2512, 7-Channel, 10 A PXI Signal Insertion Switch Module

    778572-12 - NI

    7-Channel, 10 A PXI Signal Insertion Switch Module—The PXI‑2512 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2512 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls

  • NI-9423, 24 V, 8 Channel (Sinking Input), 1 µs C Series Digital Module

    783735-01 - NI

    24 V, 8 Channel (Sinking Input), 1 µs C Series Digital Module - The NI‑9423 works with industrial logic levels and signals to connect directly to a wide array of industrial switches, transducers, and devices. Each channel is compatible with 24 V logic levels, can accept up to … 30 V discrete logic levels, and has an LED that indicates the status. The NI‑9423 offers isolation between the input and output banks from channel to earth ground. The NI‑9423 is a correlated digital module, so it can perform correlated measurements, triggering, and sychronization when installed in a CompactDAQ chassis.

  • NI-9423, 24 V, 8 Channel (Sinking Input), 1 µs C Series Digital Module

    779009-01 - NI

    24 V, 8 Channel (Sinking Input), 1 µs C Series Digital Module - The NI‑9423 works with industrial logic levels and signals to connect directly to a wide array of industrial switches, transducers, and devices. Each channel is compatible with 24 V logic levels, can accept up to 30 V discrete logic levels, and has an LED that indicates the status. The NI‑9423 offers isolation between the input and output banks from channel to earth ground. The NI‑9423 is a correlated digital module, so it can perform correlated measurements, triggering, and sychronization when installed in a CompactDAQ chassis.

  • NI-9435, ±5 VDC to ±250 VDC/10 VAC to 250 VAC, 4-Channel (Sinking/Sourcing Input), 3 ms C Series Digital Module

    779010-01 - NI

    ±5 VDC to ±250 VDC/10 VAC to 250 VAC, 4-Channel (Sinking/Sourcing Input), 3 ms C Series Digital Module - The NI‑9435 works with industrial logic levels and signals to connect directly to a wide array of industrial switches, transducers, and devices. Each channel accepts signals from ±5 VDC to ±250 VDC and 10 VAC to 250 VAC; features transient overvoltage protection between the input channels and earth ground; and has an LED that indicates the status. The NI‑9435 is a correlated digital module, so it can perform correlated operations, triggering, and synchronization when installed in a CompactDAQ chassis.

  • Multi-purpose Cable Tester and Cable Tracer

    165 CB - Standard Electric Works Co., Ltd

    ● 165 CB is an ideal tool which can test the correct pin configuration for different kinds of cables.● For testing: -RJ45/RJ11 -USB -COAX -BNC cable -Multi-wire cable● Auto-scan and manual-check function● Buzzer sound warning for wire status● 2 LED module indicators on the master unit which can do both of transmitter and receiver functions for RJ45/RJ11 cable testing. Users don't need to use the receiving unit.● 165 CB provides a variety for checking cable continuity, open status, short status and miss-wired. ● Ground (shielded ) wire test.● LED indication for wire status.● Power source : 9V battery

  • PXI 10A Fault Insertion Switch 6-chan 2-bus

    40-192-012 - Pickering Interfaces Ltd.

    This PXI fault insertion switch uses solid state switching elements and is capable of switching current up to 10A. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test: Open-Circuit. Short-Circuit between UUT connections. Short-Circuit to external signals. Through relays on each channel enable signals to the UUT to be set open-circuit. Fault Insertion Buses allow any channel to be shorted to any other channel and also enable any channel to be connected to an external signal such as Power, Ignition or Ground to simulate fault conditions. The module is supplied with 2 fault buses.

  • sbRIO-9239, Non-Enclosed, ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module

    780875-01 - NI

    Non-Enclosed, ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The sbRIO‑9239 performs differential analog input. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating. Designed for both speed and accuracy, the sbRIO‑9239 is an effective general-purpose analog module because of its resolution, sample rate, and input range. Non-enclosed modules are designed for OEM applications.

  • NI-9205, cDAQ-9171, and cRIO-9940 USB Voltage Measurement Bundle

    865683-01 - NI

    NI-9205, cDAQ-9171, and cRIO-9940 USB Voltage Measurement Bundle - The USB Voltage Measurement Bundle with NI-9205, cDAQ-9171, and cRIO-9940 includes the NI-9205 C Series Voltage Input Module and the cDAQ-9171 CompactDAQ Chassis for voltage measurements. This bundle also includes the cRIO-9940 Backshell for strain relief and operator protection from high-voltage signals. The included NI-9205 features a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. Additionally, the NI-9205 provides up to 60 V of overvoltage protection between input channels and common, and it is rated for 1,000 Vrms transient overvoltage protection.

  • PXI-2510, 68-Channel, 2 A PXI Signal Insertion Switch Module

    778572-10 - NI

    68-Channel, 2 A PXI Signal Insertion Switch Module—The PXI‑2510 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2510 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls

  • High Performance Analog & Mixed Signal Test Solutions

    Applicos - Salland Engineering

    Effective mixed-signal test solutions demand know-how and experience. Low level analog signals need to be stimulated and analyzed near fast switching digital logic. Cross talk, magnetic fields, clock jitter, ground noise and non-linearity of components, are just a few of the problems that must be addressed. Applicos knows what it takes to design and produce high quality mixed-signal test solutions. They have been servicing the mixed-signal test industry since 1993 and have established a distinguished reputation for providing our customers with high performance, cost effective solutions. In 2018 we acquired Applicos B.V. to extend our portfolio for the ATE business.

  • Semi-Rigid Test Probes Up to 6 GHz

    Fairview Microwave Inc.

    Fairview Microwave’s semi-rigid test probe assemblies come in multiple cable diameters to help when attaching the unterminated end of the probe to a circuit board trace. There are two versions including straight-cut probe ends for those that would like to customize the dimensions of the center conductor and dielectric dimensions, as well as pre-stripped probe ends that are ready for immediate use. By soldering the outer conductor to the signal ground and the exposed center conductor to the trace carrying the signal of interest, simple sampling measurements can be made without having to create a separate subassembly circuit board or add a connector to the circuit layout which can take up valuable real estate. Fairview provides 3 diameters of semi-rigid coax and 3 different lengths from 3 inches to 12 inches to fit a variety of trace widths and applications. All test probes are 100% RF tested to ensure the cable assemblies operate to 6 GHz and also to make sure that the SMA connector interface meets the 1.35:1 VSWR specification prior to shipping. To protect the small diameter coax from damage, each part is shipped in a clear protective tube that can also be used for storing the probes for future use.

  • Programmable Multi Output DC Power Supply

    LQ6324P - Aplab Limited

    - Multi Output Linear DC Power Supply- Digitally Controlled Output Settings- Store / Load 10 Sets of Output Settings in Internal Memory- USB Interface Provided- Programmable Arbitrary Variable Output by Feeding Coefficient of the Curve- User Friendly Front End- Low Cost General Purpose Laboratory Bench Unit- Fully Protected against Overload and Short Circuit- 5V/5A with Over Voltage Crowbar Protection for Digital ICs- Three Independent Outputs Electrically isolated from Each Other- Electrically Floating Outputs up to 500V DC w.r.t. Ground- Precise Regulation, Low Ripple and Noise for Both Constant Voltage & Current Operation

Get Help