Filter Results By:

Products

Applications

Manufacturers

Showing results: 91 - 105 of 228 items found.

  • Mass Interconnect

    MAC Panel

    Mass interconnect is a way of connecting test instrumentation to a device under test (DUT).  To put it simply, mass interconnect is a very large plug and socket which connects your device under test to your test instrumentation without the mess and hassle of having to connect each signal separately.

  • Hand-In Type Electromagnetic Anechoic Box (Shield Box)

    MY3710HS - MICRONIX

    Higher shielding performance than MY371080dB. Suitable for weak electric field resistance test, out-of-service test or digital forensics for mobile phone, smart phone or tablet terminal! DUT can be operated directly with bare hands while placing it in the box and looking at the inside from the shield window.

  • Semiconductor Testing

    VX Instruments GmbH

    The integrated PXI platform and the open interfacing provides extension capabilities for additional testing requirements like DUT specific resistors-networks or temperature sensors. The Test System comes with the ready-to-run GTSoftware package and allows easy programming of test sequences (GTbuilder) and fast execution in production/test mode (GTengine).

  • Flex Test Fixtures

    Z-Axis Europe

    FTFs are test fixtures which are dedicated for testing flex-based components and assemblies such as displays, touch panels and more. A weak spot in a typical functional test system is the method to connect DUT flexible cable to a circuit board where the simple method of attaching the flex directly with an ZIF or LIF connector fails.

  • Automatic Calibration Module

    ACM4509 - Copper Mountain Technologies

    ACM4509 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 9 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process. Automating the calibration routine also reduces wear and tear on the analyzer and RF cables. To perform full four-port calibration, each end of the ACM need only be connected to the analyzer once, as opposed to 18 connections with a traditional calibration. The ACM also contains a factory characterized 20dB in-line attenuator which acts as a simulated device under test (DUT). The confidence check feature loads the factory stored DUT into memory so proper calibration can be verified.

  • Automatic Calibration Module

    ACM2509 - Copper Mountain Technologies

    ACM2509 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 9 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process. Automating the calibration routine also reduces wear and tear on the analyzer and RF cables. To perform full two-port calibration, each end of the ACM need only be connected to the analyzer once, as opposed to seven connections with a traditional calibration. The ACM also contains a factory characterized 20dB in-line attenuator which acts as a simulated device under test (DUT). The confidence check feature loads the factory stored DUT into memory so proper calibration can be verified.

  • Automatic Calibration Module

    ACM2520 - Copper Mountain Technologies

    ACM2520 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 20 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process. Automating the calibration routine also reduces wear and tear on the analyzer and RF cables. To perform full 2-port calibration, each end of the ACM need only be connected to the analyzer once, as opposed to 18 connections with a traditional calibration. The ACM also contains a factory characterized 20dB in-line attenuator which acts as a simulated device under test (DUT). The confidence check feature loads the factory stored DUT into memory so proper calibration can be verified.

  • Sound Harmonics and Current Analyzer

    H74050100 - 6TL Engineering

    This analyzer is used as end of line control for electro mechanic components with electric motors, with or without mechanical reduction. While the motor is running at nominal speed, a spectrum and temporal analysis of the sound as well as a current consumption test is performed. Statistical analysis of the data acquired is also performed real-time, expediting the PASS/FAIL decision of the DUT.

  • Functional Test Fixtures

    Bloomy Controls, Inc.

    Reliable connections to device under test (DUT) test points are essential for robust functional test. Bloomy provides rugged fixtures and cable sets (ITAs) built for thousands and thousands of cycles in manufacturing environments. With the industry’s best mass interconnects and internal electronic keying, our fixtures are easy to change out and are automatically recognized by the test system.

  • Characterization Platform

    Accel-RF Corporation

    This standalone integral software and hardware platform is capable of functioning as an independent single-channel or virtual multi-channel characterization test subsystem. The platform is USB controlled to provide temperature, RF-signal and bias-control to a device-under-test (DUT) for semiconductor performance measurement. When used in conjunction with Accel-RF's embedded Pulser-Card Assembly, the test device is capable of pulsed DC and RF stimulus.

  • Frontends & Converter

    FExx Series - Rohde & Schwarz GmbH & Co. KG

    R&S®FExx external frontends extend the frequency ranges of Rohde & Schwarz signal and spectrum analyzers and signal generators up to 170 GHz. The R&S®FExx enables the up and down-conversion of the signal directly at the DUT. In an OTA environment it lowers cable losses, increases sensitivity and delivers more power at the antenna.

  • TVAC CalPod, 20 GHz

    85532B - Keysight Technologies

    CalPods provide a new and unique way to quickly and easily refresh a network analyzer calibration, at the push of a button, and without removing the DUT or re-connecting standards. Very useful in thermal-vacuum chamber testing, where it is desired to remove the thermal effects of the test cables and connectors from the DUT’s response, and where it is impractical to stop the testing to perform a normal re-calibration.

  • ±6 kV ANSI/ESDA/JEDEC HBM Test System

    HBM-TS10-A - High Power Pulse Instruments GmbH

    *±6 kV Human-Body-Model (HBM) tester according ANSI/ESDA/JEDEC JS-001 standard with C = 100 pF, R = 1.5 kΩ discharge network*Wafer, package and system level HBM testing*True HBM: the classical discharge network of the HBM-S1-A according the standard ensures compliant waveforms for all load conditions*No trailing pulses*Integrated 10 kΩ charge removal resistor*Integrated DUT HBM current sensor for real time transient current monitoring with 1V/A output sensitivity into 50 Ω digital oscilloscope input*Integrated DUT HBM voltage sensor for real time transient voltage monitoring with 1/200V/V output sensitivity into 50 Ω digital oscilloscope input*Integrated overvoltage protection of the DUT voltage sensor, DUTcurrentsensor and DC test interface for efficient overload protection of the digital oscilloscope and SMU during high voltage HBM testing*Integrated DC test DUT switch with automatic switch control*Integrated 50 Ω precision hardware trigger output for high speed digital oscilloscopes*Fast HBM measurements, typically 0.5s per pulse including one-point DC measurement between pulses*Eficient sofware for system control and waveform data management (fully compatible with TLP measurement data)*The sofware can control automatic probers for fast measurements of complete wafers*Compact size 145 mm x 82.5 mm x 44 mm of the integrated HBM pulse generator probehead*System controller size 483 mm x 487 mm x 133 mm*High performance and high quality components*Optionally available hardware upgrades to all HPPI fully integrated HBM/HMM/TLP/VF-TLP test systems TLP-3010C, 4010C, 8010A, and 8010C

  • DC Power Analyzer, Modular, 600 W, 4 Slots

    N6705C - Keysight Technologies

    The N6705C DC Power Analyzer provides unrivaled productivity gains for sourcing and measuring DC voltage and current into the DUT by integrating up to 4 advanced power supplies with DMM, Scope, Arb, and Data Logger features. The N6705C eliminates the need to gather multiple pieces of equipment and create complex test setups including transducers (such as current probes and shunts) to measure current into your DUT. The DC Power Analyzer also eliminates the need to develop and debug programs to control a collection of instruments and take useful measurements because all functions and measurements are available at the front panel. For even greater control and analysis functions, the DC Power Analyzer can be used with the 14585A Control and Analysis Software. When automated bench setups are required, the N6705C is fully programmable over GPIB, USB, LAN and is LXI Compliant. 14585A Control and Analysis Software

  • PIM Chamber

    Cuming-Lehman Chambers

    Passive Intermodulation (PIM) occurs when two or more signals are present in a passive device (cable, connector, isolator, switch, etc.) that exhibits a nonlinear response.PIM chambers vary in size and design depending on the size of the DUT; a typical PIM requirement is -110dBc or more. Cuming Lehman Chambers has successfully provided PIM Chambers with measured levels in excess of 150dBc.

Get Help