Filter Results By:

Products

Applications

Manufacturers

Corrosion

gradual degradation of a material over time

See Also: Salt Spray, Salt, Salt Fog, Corrosion Test


Showing results: 151 - 165 of 216 items found.

  • Environmental Simulation

    Weiss Technik

    We provide a wide range of systems and devices for environmental simulation. Whether you are carrying out temperature, climate, vibration, corrosion, emissions, altitude, pressure or combined stress testing, we have the right solution and can supply systems in all sizes. From series products right through to customer-specific, process-integrated systems. The choice is yours! For excellent reproducibility and precise test results.

  • Chloride/Sulfate Analyzer

    Thornton 3000CS - Mettler-Toledo, LLC

    The METTLER TOLEDO Thornton 3000CS Analyzer is an on-line instrument for direct measurement of chlorides and sulfates in pure water and power cycle chemistry samples. The analyzer continuously monitors these highly corrosive contaminants to assist in corrosion control and minimizing damage to critical power plant equipment. Early, unambiguous detection of trace levels of chloride and sulfate ions is provided with minimal operator supervision.

  • Isolation Tester UIP

    UNION INSTRUMENTS

    The devices of the UIP (Union Isolations Prüfer) isolation tester series are used to test the pore-free condition of corrosion protection coatings of pipes, vessels or plant system parts. The battery-powered device generates test voltages between 5 kV and 30 kV, which are applied to the grounded test object via test electrodes. The location of a defect is signalized by a spark-over with an additional audible warning.

  • Pressure Gauges

    Kobold Instruments, Inc.

    Diaphragm pressure gauges feature stainless steel construction for superior chemical and corrosion resistance for your intermediate pressure measurement applications. Because of the protective diaphragm seal design, these pressure gauges are ideal for use with viscous as well as corrosive fluids. Optionally, these diaphragm pressure gauges may be ordered with glycerine filling to help dampen the effects of machine vibration and pulsation of the media.

  • Ultrasonic Thickness Meters

    Bestone Industrial Ltd.

    Used for measuring thickness and corrosion of pressure vessels, chemical equipment, boilers, oil storage tanks, etc. in industries of petroleum, shipbuilding, power station, and machine manufacturing. Applicable to measure the thickness of many materials, e.g. Steel, Cast iron, Aluminum, Red copper, Brass, Zinc, Quartz glass, Polyethylene, PVC, Gray cast iron, Nodular cast iron

  • LC-4.5 Voltmeter

    5203 - M. C. Miller Company

    Model LC-4.5 is the first hand-held voltmeter to include a number of special features which facilitate corrosion and cathodic protection testing on underground structures. It is designed for field testing under almost any environmental conditions. Sealed Mil Spec. switches, sealed windows, a gasketed case and a printed circuit board with baked-on moisture and fungus resistant coating on both sides make this possible.

  • Radar Level Sensor

    VRS-20 - Valeport Ltd,

    Versatile and simple to install, the VRS-20 has been developed by Valeport to work seamlessly with the TideMaster Tide Display/Logger and other third party data loggers using RS232, RS485 and SDI-12 communication. Non-contact technology removes the installation, corrosion & fouling issues of submerged sensors, while simplifying datum control. Accuracy and performance are unaffected by changes in water density and atmospheric conditions.

  • Real Time X-Ray Imaging

    GO-SCAN C-VIEW - Teledyne ICM

    Go-Scan C-view is a light weight ruggedized real time X-ray imaging system specifically designed for hand-held inspection such, among other, Corrosion Under Insulation (CUI) inspection. It includes a high speed and high resolution CMOS imager and a battery-operated 70kV x-ray tube designed for portable field operation. The video imaging system captures images and displays them on a hand held display in real-time.

  • Dissolved Carbon Dioxide (DI-CO2) Ultrapure Water Delivery System

    MKS Instruments

    The DI-CO2 is used in single substrate cleaning tools for rinsing steps to prevent ESD effects and/or corrosion by creating UPW (ultrapure water) with precisely defined conductivity. It is a compact system for tool integration, providing conductive DI-CO2 water (Carbon Dioxide) with closed loop controlled conductivity. The conductivity is kept at a constant value under changing flow conditions by control of the CO2 concentration in the DI-CO2 water.

  • Sand Test Chambers

    Labodam

    Labodam sand and dust test chambers are corrosion resistant equipment that tests the stability, quality, reactivity, and characterists of products against the sand and dust exposed environmental conditions. These test chambers are carefully designed as per the CE and ISO standards and provide rpotection against current leakage, overload, over-current, short circuit, over temperature, motor overheating, and over pressure for safe and precise results.

  • Solar Spectrum Test Chambers

    ACMAS Technologies Pvt. Ltd.

    Thermoregulation system Solar simulation chamber made of a metallic frame and insulation cover panels The test chamber can be easily opened with one hand The height of the sample carrier can also be varied to ensure optimal irradiation of the various samples Corrosion resistant Stainless steel construction Air-cooled refrigeration unit Micro-processor monitoring and control unit Aerosol-free humidification and dehumidification Psychrometric humidity measuring system

  • Viscosity/Rheology

    Chandler Engineering

    Well known for producing the world's most capable and reliable high pressure, high temperature (HPHT) well cementing instruments, the Chandler Engineering portfolio of instruments and systems has grown to include reservoir testing systems, drilling fluid testing and corrosion testing instruments as well as many other unique solutions for reservoir evaluation, well construction and completions. Click on one of the below options for additional information:

  • Pulse Holiday Detector

    NOVOTEST SPARK-1 - NovoTest

    Pulse Holiday Detector NOVOTEST SPARK-1 designed to detect pits, flaws, and holes in different non-metallic insulation coatings (such as polymers, epoxy, bitumen, etc.) and is mostly used for oil and gas metal pipelines and other objects. The device can be used while the pipeline construction, operation or service. Tested coating thickness is up to 12 mm. Such tests are needed to evaluate the oil and gas pipelines corrosion protection reliability.

  • Gamma Spectroscopy

    ORTEC

    Gamma spectroscopy is the science (or art) of identification and/or quantification of radionuclides by analysis of the gamma-ray energy spectrum produced in a gamma-ray spectrometer. It is a widely used technique, well illustrated by the following list of examples:ICS Integrated Cryocooling System for ORTEC Radiation DetectorsEnvironmental Radioactivity MonitoringHealth Physics Personnel MonitoringReactor Corrosion MonitoringNuclear Materials Safeguards and Homeland SecurityForensics and Nuclear ForensicsMaterials TestingGeology and MinerologyNuclear Medicine and RadiophamaceuticalsIndustrial Process Monitoring

  • Portable Sulphuric Acid Dewpoint Temperature Monitor

    Walsn Enterprises Ltd.

    The fuels used in boilers, such as coal, heavy oil and natural gas, contains S. during the combustion process, S and O₂ form SO₂, and a small amount of SO₂ is converted into SO₃ under catalysis of Fe₂O₃, V₂O₅ and other catalysts. Under normal circumstances, the volume of SO₃ in the boiler flue gas is 1×10-6~50×10-6, and the water vapor is about 10%. When the temperature of the flue gas is below 200°C, SO₃ and the water vapor are completely combined into H₂SO₄ vapor. A small amount of H₂SO4 vapor will significantly increases the acid dew point. When the surface temperature of the boiler heat exchange equipment is lower than the flue gas acid dew point, the H₂SO₄ vapor will condense on the surface to become sulfuric acid solution with a concentration of about 80%, which will adhere to the surface of the heat exchanger and cause acid corrosion. Typical equipment that is prone to corrosion includes air preheaters, induced draft fans and flue walls.

Get Help