Filter Results By:

Products

Applications

Manufacturers

Corrosion

gradual degradation of a material over time

See Also: Salt Spray, Salt, Salt Fog, Corrosion Test


Showing results: 211 - 216 of 216 items found.

  • Level System

    Universal II - AMETEK Drexelbrook

    The Universal II level transmitter offers increased reliability, low maintenance and an intrinsically safe design for dependable level measurements in all kinds of process liquids, slurries, granulars and interfaces.Universal IIThe Universal II is a two wire level transmitter that eliminates the need for line power in the field and saves costs for additional hardware. It provides reliable level measurements in all kinds of process liquids, slurries, granulars and interfaces.When powered from an approved source this level transmitter can be made intrinsically safe. Its rugged contruction resists corrosion and abraision. The no moving parts design eliminates break downs.The Universal II level transmitter utilizes RF Admittance technology with manual calibration and a 4 – 20 mA output signal. The patented Cote-Shield circuitry ensures accuracy and reliability regardless of product build-up on the level transmitter.This level system is unaffected by changes in the process material density, pressure, or temperature variations.

  • Harness Design and Manufacture

    Teledyne Marine Impulse-PDM

    When designing an underwater cable harness, there are some factors which need to be considered, and we have produced the following list as a guide for customer information:Component considerations:- Electrical requirements- Mechanical considerations- Quality requirements- Reliability- Design redundancy (contact count)- Connector selection (type and form)- Locking requirements- Backpotting requirements- Waterblocking in moldings- Cable specification- Cable jacket material and compatibility with elastomers- Abrasion resistance- Stiffness profile at termination- Connector format (straight or right angle)- Molding format (straight or at an angle)- Clearance allowance for molding and cable routing- Elastomer compatibility (eg oil filled units)- Metalwork selection re: corrosion and cathodic delamination- Surface finish for metalwork as appropriateOperational considerations:- Operating depth profile (not just max. depth)- Tensile loads- Torsional loads- Bending loads- Bend control requirements (to limit bending at termination)- Deployment and recovery loads- Dynamic loading-Flow turbulence effects.

  • Connector Board for Cable and Harness Tester

    CB49 - CAMI Research Inc. (CableEye®)

    Populated with solder pads to accept a suite of TE-Connectivity Micro-MaTch connectors, this board addresses markets plagued by vibration and fretting corrosion, and requiring "miniaturized connectivity". Rated to 500Vdc/350Vac, the CB49 may be used on all CableEye models. The CB49, sold without connectors, contains nine sets of 20 solder pads accommodating numerous configurations of Micro-MaTch connectors. There are nine preset locations for automatic detection & display of 4, 6, 8, 10, 12, 14, 16, 18, and 20-pin connectors. Yet, any single set may be fitted with any combination of lower pin count connectors that total to 20 or less (e.g. a 14-pin with a 4-pin). Connectors soldered in non-preset positions will also appear graphically correct once they are mapped with PinMap (optional software). Sold as a set of two boards, each Micro-MaTch test board may be paired with other CableEye adapter boards to accommodate any combination of connectors.

  • pH & ORP Sensors

    Barben Analytical

    The Barben Analytical Performance Series products are 3rd generation combination pH/ORP electrodes targeted at harsh, industrial measurement applications. High pressures, strong chemicals, and elevated temperatures typically shorten the lifespan of conventional double-junction pH probes. In these applications the Performance Series sensor offers extended sensor lifespan, as well as decreased drift, and longer calibration intervals. Each sensor is manufactured with our patented Axial Ion Path® reference technology, proprietary Low-Noise & High-Temp Signal Cable along with proprietary ruggedized, high temp and coat resistant glass formulations. A wide selection of sensor body styles and process fittings in a variety of corrosion resistant materials allow direct replacement of short-lived OEM pH/ORP sensors. Barben Performance Series sensors are compatible with all major manufacturers of pH analyzers and transmitters. Upgrade your analytical measurement without the hassle and expense of replacing costly field instruments.

  • Toxic Gas Sensor

    Model 100 - Teledyne Gas & Flame Detection

    Model DM-100 Series sensors feature intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor is packaged in an electro-polished 316 stainless steel housing fitted with a ¾ inch NPT thread. The plug-in, field replaceable sensor cell features large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Signal conditioning electronics are completely encapsulated in the sensor housing adding a high level of durability to the design. The packaging is XP-intrinsically safe. This innovative design marks a return to a simple, more affordable, and durable gas detection sensor without compromising quality.Model DM-100 sensors provide a 2-wire loop powered 4-20 mA current signal equivalent to the sensor range of detection. Upper enclosure options are aluminum and stainless steel. Additional accessories include wireless communications, a loop powered digital display. Each sensor is shipped with a splash guard with integral calibration port. Detcon’s toxic gas sensors have a long shelf life and are supported by an industry-leading warranty.

  • Integrated Potentiostat and Multiplexer

    EmStatMUX8 - PalmSens BV

    Based upon the EmStat range, there are two types of multiplexers to suit most types of sensor array work. The MUX8 is the most flexible offering the ability to connect arrays made of up to eight working electrodes in two or three electrode cell types and chips sharing a reference electrode and/or counter electrode. The MUX16 is suitable for sensor arrays or chips with sixteen working electrodes all sharing a RE and/or a CE. Both instruments are suitable for laminated layer corrosion analysis.The potentiostat is controlled and powered by USB and is used with PSTrace allowing for simultaneous sampling of each channel at a rate of 25 ms/channel. Standard packaging includes a shielded cable with connections for a working, a counter and a reference electrode by means of 2 mm banana connectors and mini-crocodile clips, a stripped end, Dsub-37 terminated flat cable and a USB cable. To make connections to chips simpler the Connection Terminal is an optional extra providing clearly marked screw terminals to the electrodes and can be directly joined to the ESMUX via their D-Sub connectors.

Get Help