Filter Results By:

Products

Applications

Manufacturers

Showing results: 226 - 240 of 933 items found.

  • Rain Test Chamber

    Wewon Environmental Chambers Co, Ltd.

    Water pump for rain test chambers uses highly pressure stainless steel pump, ensure water pressure and flow of the test cycle, the pump is installed in the side of the IP test device, and both ends of the inlet and outlet to set up the joint, easy to replace and repair. Water tank can be disassembled,The corresponding joint or hose connection is arranged in the water pipe connection.

  • Thermal Shock Chamber

    ETS-Series - Envisys Technologies

    air-to-air and liquid-to-liquid Thermal Shock Chambers from Envisys are available in different volumes to suit the varied testing needs. Horizontal or vertical models consisting of cold and hot zones with product carrier basket of sizes 50, 100, 150, 300, 600 and 900 litres which transfers the specimen under test between cold and hot zones using electro pneumatic / motorized basket movement.

  • Medium-size Reverberation Chamber

    E-Series - Emite Ingeniería SL. Ed

    The E medium-size multicavity Reverberation Chamber Series represents that state-of-the-art in reverberation chamber technology. The E-Series can make single measurements, batch tests, protocols or campaign tests for different frequency bands, different technologies and different channel models, running overnight without human intervention. Embedded frequency-, mode-, source- and platform-stirring in a double-shielded set of cavities allow Passive MIMO (Efficiency, Correlation, Diversity Gain, MIMO Capacity and others), Active MIMO OTA (TRP, TIS, TPUT, MTS, CQI, M2TxDT, RSRP, MCL and others) and Time-Domain MIMO (DL/UL TCP/UDP TPUT, RMS DS, STD, PL, CBW, Mute%, eNodeB, VDT-OTA) measurements up to 8x8 and 8DLCC to be performed for antennas and devices up to 50cm and 50kg ranging from 2G to 4G, covering all available cellular and wireless technologies to date, including wearables devices, sound acoustic mute, WLAN and W-IoT testing. There is no RC in the market more advanced than the E-Series.

  • Environmental Test Chamber

    Lisun Electronics Inc.

    The chamber is produced by SUS304 Steel, the temperature keeping material is produced by Polyurethane hard foam and ultra-fine fibre glass, the doorframe heat insulated by Double high temperature aging silicone rubber door sealing strip.The temperature controller is used by Korean TEMI display in English/Chinese and German Siemens PLC, it can be communicated to PC via RS-232. The temperature accuracy is 0.1 and humidity is 0.1%R.HThe temperature sensor is platinum PT100 Ohms/MV resistor

  • Halt Hass Chambers

    ACMAS Technologies Pvt. Ltd.

    HALT and HASS chambers from WEIBER provide extreme temperature & vibration capabilities used during the product design and manufacturing cycles to compress the time normally required to identify design and process weaknesses. HALT techniques are important in uncovering many of the weak links inherent to the design and fabrication process of a new product. HASS techniques are incorporated during the production phase to find manufacturing process defects that could cause product failures in the field.

  • Chamber Controllers & Software

    Cincinnati Sub-Zero Products

    Designed off of our previous controller platform with familiar features in an improved interface, added functionality for ease and fewer steps to accomplish your daily testing needs. Remotely monitor and control your chambers and receive text/email alarms. From the home screen users can now manually control, run or stop a profile and view a snapshot of current activity like actual/setpoint values, alarm, datalogging, profile, security, IP address information and more.

  • Enlarge Environmental Chamber

    REXMED REC-450 - REXMED Industries Co., Ltd.

    MOD. REC-450, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,644 Watts, 12,433 BTU/hr, 3,140 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L60 X W80 X H85cm, Capacity: 408L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Enlarge Environmental Chamber

    REXMED REC-250 - REXMED Industries Co., Ltd.

    MOD. REC-250, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,140 Watts, 10,700 BTU/hr, 2,702 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L60 X W80 X H85cm, Capacity: 408L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Enlarge Environmental Chamber

    REXMED REC-480 - REXMED Industries Co., Ltd.

    MOD. REC-480, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 2.3KW X 2pcs, Humidity heater: 4.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 5,270 Watts, 18,000 BTU/hr, 4,545 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L100 X W80 X H100cm, Capacity: 800L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • RF Diagnostic Chamber

    DST200 - Rohde & Schwarz GmbH & Co. KG

    The R&S®DST200 RF diagnostic chamber is the ideal environment for RF analysis during development. It supports a wide range of radiated test applications for wireless devices and fits on any R&D lab bench, where it can be used at all times during the product design and optimization phase. The R&S®DST200 effectively assists in achieving high first-time pass rates during final type approval, which saves time and money.

  • Chamber Controller Software

    Crystal instruments

    EDC (Embedded Device Control) is specifically designed software for Sentek chamber system controllers running Temperature and Humidity environmental tests. The EDC software features an intuitive interface, a powerful data review function and live data viewing. The combined EDM controller software provides one central location to set up parameters and a schedule between all three environments, with or without a connected controller. The powerful import and export features allow users to easily transfer test configurations between computers.

  • Waterproof Test Chamber

    JL-XC - Lisun Electronics Inc.

    JL-XC series waterproof test chamber is mainly used for small electronic and electrical products. Such as lamps, electrical cabinets, electrical components and so one. The products are tested for physical and other related properties under simulated climatic conditions. After the test, it is judged whether the performance of the product meets the requirements by verification, so as to be used in the design, improvement, verification and factory inspection of the product. Comply with IEC60529:2001 《Degrees of protection provided by enclosures (IP Code)》, GB4208-2008 《Shell Protection Grade (IP Code)》 14.2.8 Terms and GB7000.1 《Lamps Part 1: General Requirements and Tests》 9.2.9 Terms.

  • Rain Test Chambers

    Shanghai Morningtest Environmental Chambers Co.,Ltd.

    Rain test chambers for ingress protection testing simulates rain/water test as per IEC 60529 and DIN 40050-9((IP Code standard)) test standard. • IPX1 Protection against vertically dripping water• IPX2 Dripping water ± 15° from vertical• IPX3 Protection against spraying water• IPX4 Protection against splashing water• IPX5 Protection against low pressure jetting water• IPX6 Protection against high pressure jetting water• IPX7 Protection against temporary immersion• IPX8 Protection against continuous immersion• IPX9K Extremely high pressure jetting water

  • Cytogenetic Drying Chamber

    CDS-5 - Thermotron Industries

    Developed in cooperation with Mayo Clinic, Thermotron's Cytogenetic Drying Chamberthe CDS-5was specifically designed for conducting cytogenetic slide drying tests during harvest of in situ and non-in situ grown cultures. The CDS-5 provides the optimum controlled temperature and humidity environment required to achieve ideal chromosome spreading results. As evidenced in research conducted by the Cytogenetics Laboratory at Mayo Clinic, the CDS-5 facilitates reliable and repeatable chromosome spreading. The use of an environmentally controlled drying chamber is a practical and cost effective way of achieving ideal chromosome spreading in a routine and highly consistent manner. Favorable chromosome spreading results can be obtained for both in situ and non-in situ cultures including PHA stimulated lymphocytes, bone marrow, amniocytes, and fibroblast.

  • Walk-In Test Chamber

    Sanwood Environmental Chambers Co ., Ltd.

    Energy-saving design: Adopting PID + PWM principle of VRF (refrigerant flow control) technology to achieve low-temperature energy-saving operation (electronic expansion valve according to thermal energy conditions refrigerant flow servo control technology) low temperature working state, the heater does not participate in the work, through PID + The PWM regulates the flow rate and flow direction of the refrigerant, and regulates the three-way flow of the refrigerant pipe, the cold bypass pipe, and the hot bypass pipe to achieve automatic constant temperature to the working chamber. This method can reduce energy consumption by 30% under low temperature conditions. The technology is based on Danish Danfoss' ETS series of electronic expansion valves, which can be used to smoothly adjust the cooling capacity for different cooling capacity requirements, that is, to achieve the compressor cooling capacity adjustment when different cooling rate requirements are met.

Get Help