  • Extra Large Photoreactor With Heating Capabilities.

    Luzchem Research Inc.

    The new Extra Large Photoreactor(LPD) is designed to meet stringent specifications while maximizing convenience of operation. Features include:*Sequential photochemical and thermal cycles in a single chamber optimized for dual photothermal decontamination.*Programmable exposure time.*Includes rotor/carousel to ensure samples are evenly exposed to UV irradiation.*Front window with UV protection (420 nm cut off) allows operator to inspect. No UV exposure and no need to open compartment.*Magnetic interlock shuts down system for operator safety if front window is removed.

  • X-RAY Fluorescence Measuring Instruments

    FISCHERSCOPE X-RAY/XUL - Helmut Fischer AG

    For coating thickness measurements in the electroplating industryFixed aperture and fixed primary filterX-ray tube with a slightly larger primary spot, well suited for applications with measurement spot sizes starting at about 1 mmLow-energy beam components are excited with lower effectiveness, however for standard applications measuring the thickness of typical electroplated coatings such as Cr, Ni, Cu, this poses little to no problemMeasuring direction from bottom to top, this allows for quick and easy sample positioningLarge measurement chamber with a cutout (C-slot) Standard X-ray tube, proportional counter tube

  • Plasma Etcher / Asher

    PA-3000-A ETCHER - TEK-VAC INDUSTRIES Inc.

    Process chamber with plasma view window and full access hinged door. RF hot process shelves with opposing ground electrodes. Throttle valve. Capacitance manometer. Internal pumping system with option for Fomblin filled chemical series mechanical pump. Flow control electronics and cabinet. Up to four mass flow control assemblies can be incorporated into our system. RF matching network and 600 watt maximum power supply. Fully enclosed cabinet. Custom internal fixturing to accommodate specific substrate shapes and sizes. Plasma gas selection for optimal performance.

  • Neutron Detectors

    Exosens Group

    As a neutron has no charge, a neutron detector incorporates a neutron-to-ionisation particle converter.The incident neutrons are captured by the converter material which then produces (detectable) ionising particles by means of a nuclear reaction.Photonis gas-filled detectors are designed to detect thermal neutrons (En < 0.025 eV), so the capture cross-section of the detecting material must be as large as possible for this low energy. We therefore use 235U (580 barn at 20 °C) for our fission chambers, and 10B (3840 barn at 20 °C) for our boron-lined proportional counters.

  • Mid-Range Gas Filter Correlation CO2 Analyzer

    Model N360M - Teledyne Advanced Pollution Instrumentation

    The Model N360M measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the eff​ects of ambient CO2, if necessary.

  • Gas Filter Correlation CO Analyzer

    Model T300 - Teledyne Advanced Pollution Instrumentation

    DescriptionFeaturesSpecificationsApplicationsDownloadsMaintenanceThe Model T300 measures low ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 14 meters. The energy loss through the sample cell is compared with the span reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing extreme sensitivity.

  • Gas Filter Correlation CO2 Analyzer

    ​Model N360 - Teledyne Advanced Pollution Instrumentation

    The Model N360 measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the eff​ects of ambient CO2, if necessary.

  • Bus Management Test System

    Data Patterns Pvt. Ltd.

    Solution to test redundant Architecture of BMUComprehensive test system performing tests of > 3000 I/O's Special test circuits using hybrid / ceramic components to operate in Thermovac chamber Tests various subsystem functionalities like, AOCS, Sensor Electronics, Telemetry, Tele-command with Self test and application test software

  • Audio Testing

    Quest Engineering Solutions

    Sound Power testing is required in many international standards. Quest also offers a variety of additional acoustic tests and the design experience to help you develop quieter products for your customers. Our chamber is able to cancel out all outside forces as well with its free floating floor boards.

  • RFID Test Instrument

    RAIN Xplorer - CISC Semiconductor GmbH

    The CISC RAIN Xplorer is a unique RFID test product developed for convenient tag frequency sensitivity, communication range, and backscatter measurements. The RFID tester is designed for open area tests and measurements in an RF-controlled environment using portable or fixed RF test chambers. The system is supplied with software and a reference tag for self-calibration.

  • Switchgear Test Systems / Circuit Breaker Testing

    KoCoS Messtechnik AG

    ACTAS test systems provide precise information as to the condition of the chamber and drive unit without requiring them to be opened. The sheer number of parameters to be determined, the wide variety of different types of switchgear equipment in use and the harsh environmental conditions encountered during on-site tests place extreme demands on test equipment.

  • CO2 Carbon Dioxide Probe

    HD320B2 - Delta OHM S.r.L.

    The probe measures the carbon dioxide concentration in air. It’s indicated for checking and monitoring the indoor air quality. Typical applications are the check of the air quality in all the buildings where there is a crowd of people (schools, hospitals, auditoria, canteens, etc.), in the working places to optimize the comfort. CO2 measurement is obtained with an infrared special sensor (NDIR technology: Non-Dispersive Infrared Technology) that, thanks to the use of a double filter and a special measurement technique, warranties precise, stable and long-term measurements. The air to check is spread inside the measurement chamber through the protection membrane placed at the top of the probe.

  • Masks Bacterial Filtration Efficiency Tester

    Sataton Instruments Technology CO., Ltd

    Face Masks bacterial filtration efficiency BFE tester is to determine the bacterial filtration efficiency (BFE) of medical face mask materials by employing a ratio of the upstream bacterial challenge to downstream residual concentration of the tested medical face mask materials. The tester provides certain flow rate of bacterial aerosol. The operator can measure the number of colony forming units passing through the medical face mask material, which is clamped between a six-stage Anderson cascade impactor and an aerosol chamber, expressed as a percentage of the number of colony forming units present in the challenge aerosol.

  • Xenotest

    220/220+ - Atlas Material Testing Technology

    The Xenotest 220 and Xenotest 220+ are large capacity lightfastness testers dedicated for textile testing. They come with premium on-rack light and temperature sensor and non-aging optical filter technology. With the ability to test 38 samples, the 220 Series provides nearly twice as much capacity in the same footprint compared to 150S+. The combination of its large test chamber and the efficient use of power and water make it today‘s most economic air-cooled instrument available. It complies to standards ISO 105 B02, AATCC TM16 (option 3), and Marks & Spencer C9, C9A.

  • Walk / Drivable test facilities

    TW / CW series - Clima Temperatur Systeme

    Walk or drive-in temperature and climatic test chambers can be designed from CTS by a standardized grid system affordable in all sizes. The refrigeration performance data are adjusted here by our experienced sales and project engineers on your testing out. The walk / drive-chambers are ideal for larger components and finished products. CTS as a medium sized company attaches great importance to the detail quality of the equipment components, with only the best supplier products such as compressor and solenoid valves are used. Your resulting advantages are trouble-free long-term operation and thus no loss of valuable test time.