Showing results: 481 - 495 of 1014 items found.
-
Haomai Electric Power Automation Co.,Ltd.
The laser-based photoacoustic spectroscopy transformer oil and gas online monitoring system developed has a lot of advantages comparing with the traditional oil chromatography oil and gas online monitoring equipment and wide light source photoacoustic spectroscopy transformer oil and gas monitoring system. Please check the following figure to see the details:
-
GDZRC-5A -
HV Hipot Electric Co.,Ltd.
GDZRC series DC resistance tester is designed to measure DC resistance of inductive devices, such as transformers and power inductors. It uses new power technology,with the features of fast measurement,small size and high accuracy of measurement,which is ideal equipment of measuring transformer winding and DC resistance of big power inductance equipment.
-
Bloomy Controls, Inc.
Bloomy's VDT/Resolver Simulation Module offers eight channels of variable differential transformer (VDT) sensor simulation at an unmatched price point. Its highly-flexible nature allows each channel to be configured independently for simulation of a linear variable differential transformer (LVDT), a rotary variable differential transformer (RVDT), or a resolver. Versatile, separate E1 and E2 returns allow each channel to be connected in a 4-, 5- or 6-wire configuration. The included VeriStand SLSC driver also allows each channel to simulate two 4-wire sensors where shared excitation is acceptable.
-
-
Amprobe Test Tools
Cut unscheduled downtime and reduce shock hazards by testing wires, cables, transformers or entire electrical systems.
-
Carl E. Holmes Company
CEHCO manufactures Transformer Rectifier Assemblies for Crane Applications. We offer standard products and customized solutions.
-
TWR-H Series -
IBEKO Power AB
Handheld TWR-H device is DV Power single-phase instrument designed for measuring transformer winding resistance and turns ratio.The instrument has two output DC sources for measuring transformer winding resistance. The first DC source can output up to 2 A DC and is used for injecting current to the transformer’s high voltage winding. The second DC source can output up to 10 A DC and is used for testing the transformer’s low voltage winding. This is especially useful when measuring winding resistance of distribution transformers. These transformers have large turns ratio and therefore a big difference between resistances of high voltage and low voltage windings. Upon the winding resistance test, it is also possible to demagnetize the transformer core. The demagnetization process is completely automatic and safe.Together with the turns ratio, the instrument also measures excitation current and phase shift. This enables detecting transformer core or winding turns failures which cannot be spotted by measuring turns ratio only. The instrument can output test voltage up to 40 V AC for this test, but it can also output a very low test voltage of 1 V AC which is necessary for turns ratio verification of the majority of current transformers.TWR-H is powered by an internal Li-Ion battery. Up to 100 tests can be performed with a fully charged battery.
-
Techimp HQ S.r.L
TD Guard Intelligent Sensor is an on-line CONTINUOUS Capacitance and tan-δ monitoring system for transformer bushings. TD Guard Intelligent Sensor is the first and only instrument on the market providing absolute Tan-δ measurement in on-line permanent monitoring of transformer bushings, granting the best level of diagnostic leverage and reliability. Sensitivity better than 10-4.
-
T-REX -
Raytech AG
The Raytech three phase voltage system option T-Rex is an optional system accessory for 3-Phase transformer ratio meter test sets designed by Raytech (i.e. TR-MARK III). T-Rex was designed to give Engineers and Test Technicians the ability to test the phase relationships and actual voltage ratios of transformer windings while applying three phase voltage.
-
Hilkar
Arc Furnace Reactors are serially connected reactors that are installed in the supply systems of arc furnace transformers to stabilize arc and limit the unstable arc furnace current and voltage drop which optimize their melting process. These buffer reactors are connected in series to the primary side of the furnace transformer. Typically these reactors are tapped coils and manufactured as per customer'stap requirements.
-
LET-4000-R -
EUROSMC, S.A.
Regulation and Measurement Module performs the regulation of the DC current and is made with a variable auto transformer (Variac) regulating a three phase DC current, with a power of 8KVA and a three phase transformer of 8KVA with 2V nominal power in the secondary windings. A built-in ammeter and a timer give the information of the current injected and the operation time of the relay under test.
-
Weshine Electric Manufacturing Co., Ltd
Transformer iron core grounding current tester is a high-precision clamp meter specially designed for measuring AC leakage current, current and voltage. Large diameter (80×80mm) can clamp φ80mm cable, or 96mm×4mm flat steel ground wire, suitable for cables Leakage detection and transformer grounding flat steel leakage measurement.
-
-
-
DLx -
North Atlantic Industries
Linear Variable Differential Transformer (LVDT) and Rotary Variable Differential Transformer (RVDT) are transformer-type voltage/current transducers that convert a linear/rotary movement of a core/shaft to a multi-wire differential AC electrical signal. Both deliver signals linearly proportional to the position of a shaft (magnetic induction core). An LVDT/RVDT simulator is used to convert digital positional commands to corresponding AC signals.