Filter Results By:

Products

Applications

Manufacturers

Similar Topics: Transformers

Transformer

transfers of electricity from one circuit to another by electro-magnetic induction.

See Also: Transformer Testers, Power Distribution, Coil


Showing results: 766 - 780 of 1014 items found.

  • Power Supplies

    Campbell Scientific, Inc.

    Reliable power supplies enable data acquisition systems to continuously acquire and process data. Because our components use minimal power, many of our systems can be run using sealed rechargeable or alkaline batteries. Systems that require more power are often supplemented with external rechargeable batteries, regulators, ac transformers, or solar panels.

  • AC/DC Withstanding Voltage& Resistance Tester

    TH9201 - Changzhou Tonghui Electronic Co., Ltd.

    TH9201 AC/DC withstanding voltage & insulation tester is a kind of Hipot Tester. Due to simple and compact structure, mature technique, brand new structure and operating interface, the operation becomes more convenient, and more practical functions are included as well. TH9201S can be widely applied in transformer, device, component especially for winding safety inspection.Withstanding voltage test

  • AC/DC Withstanding Voltage& Resistance Tester

    TH9201B - Changzhou Tonghui Electronic Co., Ltd.

    TH9201 AC/DC withstanding voltage & insulation tester is a kind of Hipot Tester. Due to simple and compact structure, mature technique, brand new structure and operating interface, the operation becomes more convenient, and more practical functions are included as well. TH9201S can be widely applied in transformer, device, component especially for winding safety inspection.Withstanding voltage test

  • Open Loop Current Sensor

    C03 30A - Luksens Technology GmbH

    The C03 offers efficient and precise sensor solutions for direct, alternating and pulsed currents in industrial, commercial and communication systems. It consists of three main components: an accurate, linear Hall sensor with low temperature drift, a flux collector and a transformer. It is characterized by a very low resistance and thus lowers power loss and temperature drift - for optimal performance.

  • High Current Winding Resistance Meter

    SG5002\SG5003\SG5008 \SG5009 - Shanghai Jiuzhi Electric Co., Ltd.

    The SG5002 \ SG5003 \ SG5008 \ SG5009 high current resistance meters are special designed for high performance measurement of high inductance, low value resistances such as transformer windings, motors, breakers, switchgear etc. Unlike normal resistance meters these instruments have a built-in high-speed discharge circuits for safe discharge of the stored energy in a measured inductance.

  • Surge Tester (Impulse Winding Tester)

    SS6815 / SS6815F - Sanshine Electronis Co., Ltd.

    Surge testers (impulse winding tester) is used for testing and check the insulation grade of turns between turns, insulation grade of layers between layers, insulation grade of windings between turns. It is used widely for transformer, current sensor, voltage sensor, relay, contactor, inductor, motor, generator, valve coil, voice coil, etc.

  • Automatic Insulation Oil Dielectric(breakdown) Test

    HDIIJ-80 - HD Power Test Equipment Co.ltd

    Automatic Insulation Oil Dielectric(breakdown) Tester is used to carry on power frequency dielectric break down test on the transformer oil, capacitor oil, electric device, insulation tool, electric manufacturer and etc. It adopts full auto digital microcomputer, which has the function of high accuracy, strong anti-interference ability and safe reliability

  • PCI Bus Synchro - Resolver - LVDT I/O Cards

    PCI Synchro - Computer Conversions Corporation

    Proven "Whole" Std. ConvertersOptimized Thermal ManagementExternal Synchro AMP I/O100% Transformer Isolated I/OPermits 2 wire X/Y Stators(Air)No External Parts or Power RequiredReference Powered(NAVAL) Options10-16 BIT Resolution ProgrammableVirtually Indestructible Outputs1.2 to 4.5VA High Power ModelsMix/Match Input & Output TypesSimultaneous Fine/Coarse Transmit For Multispeed Outputs

  • Audio Impedance Testers

    1506 IM - Standard Electric Works Co., Ltd

    ● High quality Taut Band movement.● Battery operated.● Timer function for hands free use.● Battery indicator.● The tester measure with a frequency of 1kHz.● Measure speaker’s impedance.● Measure speaker lines (connected to load).● Help to calculate and check audio power systems.● Ideal for public address installation and maintenance.● Measure transformer impedances.

  • Liquid Dielectric Test Cell

    LT-4123 - Lambient Technologies

    The LT-4123 Liquid Dielectric Test Cell is designed for testing the quality of materials such as the insulating oils used in transformers and the resins used in the manufacture of thermosets. With the LT-4123 Liquid Dielectric Test Cell, users can measure the AC loss characteristics and permittivity of liquids. The data gleaned from these measurements are used to set quality benchmarks for fluids during testing and manufacturing.

  • Compact Automatic Voltage Regulating Relay With Built- In TPI

    Neutronics Manufacturing Co.

    NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.

  • Compact Automatic Voltage Regulating Relays

    Neutronics Manufacturing Co.

    NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.

  • Automatic Voltage Regulating Relay- Standard Model

    Neutronics Manufacturing Co.

    NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.

  • Digital LOOP/PSC/EARTH Tester

    1824 LP - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Measures Earth Resistance without the need for poles in the ground or external measuring wires.● Earth measurement uses the real earth current path and the current generated by the electric network, without the need for any disconnection.● The Earth Resistance displayed is exactly the earth resistance that the earth current will need to go through if an earth fault occurs. (you do not need to add all the bonding points and connection paths)● Displays voltage supply at the transformer(Line to Neutral), without loading the transformer.● Single one smart push button operation; ON, Scroll through results and menus.● Checks wiring integrity (LEDs).● Auto-off / Auto-ranging (software range).● Color-coded test leads.● Combined prospective short circuit current, loop, and earth tester.● Loop test for L-E and PSC between L-N.● Voltage test L-N.● Display can be customized for large orders.

  • ESU Analyzer

    ESU-2050 - BC Group International Inc.

    The BC Biomedical ESU-2050 ESU Analyzer is the first instrument of its kind on the market. Designed through extensive collaboration with several of the world's leading electrosurgery generator manufacturers. It is the only ESU Analyzer on today's market with a 1% reading level of accuracy. Calibration quality analyzer; uses external precision non-inductive test loads and wide band current transformer.

Get Help