Showing results: 721 - 735 of 1014 items found.
-
doblePRIME Delphi -
Doble Engineering
The doblePRIME Delphi is a dissolved gas analysis (DGA) monitor that helps you track transformer health by providing early warning signs of problems such as overheating, insulation degradation or mechanical movement within the transformer.The doblePRIME Delphi provides this valuable information in real time, second by second, through analysis of the insulating oil.
-
HT7051 -
HT Italia Srl
HT7051 has been developed to measure insulation resistance with test voltage programmable up to 5kVDC and measuring range up to 10TΩ which makes it very useful in any industrial application (tests on electric machines, power transformers, electric cables, electric boards, generic devices, etc.) within BT.
-
C Series -
Titan Tool Supply, Inc.
C Series small-diameter borescopes are designed for general use in inspection areas with diameters as small as 0.40" (10.2mm). 6 models cover a wide range of working lengths from 6" to 60" (152.4mm to 1524mm). Standard models include a wall-plug transformer. An optional flashlight adapter allows for in-field illumination and use.
-
Supreme Instrument Laboratories
Single Phase A.C. High Voltage Test set (BDV Flash Test) suitable for operation on 230 Volts, A.C. 50 Hz., designed for carrying out dielectric test on transformers, electrical switchgears, and installations. It operates on single phase A.C. and provides an output voltage zero to maximum rated voltage.
-
doblePRIME PD-Guard -
Doble Engineering
The doblePRIME PD-Guard continuously monitors partial discharge (PD) in equipment such as transformers, rotating machines, cables and switchgear.The doblePRIME PD-Guard provides local alarms and will communicate data and notifications across standard interface channels and through to networked supervisory systems. It analyzes RF emissions in the HF, VHF and lower UHF ranges.
-
Columbia Research Laboratories
The Columbia Model LMT-50 is a unitized rugged package consisting of tandem linear variable differential transformers (LVDT's) with probe assembly. The LMT-50 is designed so that the likelihood of a single failure affecting both output signals is extremely improbable. The model LMT-50 offers flight proven performance, even in the most severe environments.
-
R.R.Transformers & Equipments
High Voltage Breakdown Testers also known as Hipot Testers or Insulation Testers are a necessity for any Transformer testing, Substation equipment testing, Cable testing, Panel testing and testing of various insulating materials. Insulation testing is very important to ensure and maintain the safety of electrical equipments and also for the safety of operator.
-
TECHIMP PD Hub™ -
Techimp HQ S.r.L
Techimp’s Partial Discharge (PD) Monitoring systems usually consists of a Central Unit and distributed Data Acquisition Units – the PD Hub™ - able to acquire and process the PD signals locally detected through PD sensors installed on each of main electrical assets (generator, transformer, HV cables and GIS).
-
YL Series -
Shanghai Jiuzhi Electric Co., Ltd.
The SF6 gas insulated standard capacitor is used together with a C and tan delta measuring bridge as the comparison standard leg of the bridge. It is used as Capacitance standard in measuring bridge Circuits to measure the dielectric dissipation Factor tand, Further-more, It can be used as high-voltage capacitor for voltage divider circuits of high-voltage transformer test.
-
SS108A series -
Sanshine Electronis Co., Ltd.
Bobbin winding coil testers are used to test various coil of turns. Such as: generator winding turns, transformer winding turns, motor winding turns, inductor winding turns, contactor winding turns, relay winding turns, sparking winding turns, ignition winding turns, speaker voice coil, etc.
-
R.R.Transformers & Equipments
High Voltage Breakdown Testers also known as Hipot Testers or Insulation Testers are a necessity for any Transformer testing, Substation equipment testing, Cable testing, Panel testing and testing of various insulating materials. Insulation testing is very important to ensure and maintain the safety of electrical equipments and also for the safety of operator.
-
1010 CL -
Standard Electric Works Co., Ltd
● Rotary scale which presents only one scale in windows at one time to avoid any possible reading errors.● Pointer lock function freezes the reading in dimly lit or hard to reach places.● Ω range ideal for checking the continuity or relays, transformers and motor coils.● TAUT BAND movement.
-
MC151 -
Powertek LLC
MC151 Current calibrator is an accurate current source capable of 120 A. Typical uses include calibration of current sensors, current probes, current transformers, shunts, ammeters, DMMs or as stable current source for test and development applications. The calibrator is equipped with a built-in multimeter that can be used for simulation of programmable transconductance or current amplifier.
-
MMR-650 -
Sonel S.A.
Designed to measure very low resistances of both resistive and inductive types of objects, including amorphous core transformers. This product is made to be used in power plants, railways and maintenance companies, to measure welded and soldered connections, equipotential bondings, earthing conductors, contacts, bolted connections, windings of motors and power transformers and other resistive and inductive objects. MMR-650 can be also utilized on a production lines (eg. at the final production control stage). An innovative combination of a high-performance measuring device with a modern user interface and advanced data management system. Wireless data transmission, enhanced system of 2D codes and ability to print labels to identify test items, all contribute to bringing new quality of work and allow the user to perform a wide range of measurements.
-
Extech PQ3450-30 -
Extech Instruments Corporation
The PQ3450 is a 3-phase power analyzer/data logger capable of logging up to 30,000 sets of measurements in Excel format on a removable SD memory card. Large dot-matrix, sun-readable, numerical, backlit LCD with easy-to-use onscreen menu. Full system analysis with up to 35 parameters. Adjustable Current Transformer CT (1 to 600) and Potential Transformer PT (1 to 1000) ratio for high power distribution systems. Log up to 30,000 reading on a removable SD memory card in Microsoft Excel format. Wide sampling rate range (2 seconds to 2 hours). Built-in Clock and Calendar. Complete with 4 voltage leads with alligator clips, three 3000A flexible current clamps, 8 AA batteries, SD card, 100-240 Volt AC adaptor and case.