Showing results: 451 - 465 of 1014 items found.
-
TYPE JF -
Shanghai Jiuzhi Electric Co., Ltd.
TYPE JF Partial Discharge Shielding Room (Factory Building) is suitable for the partial discharge experiment and impact test in different voltage band (110KV, 220KV, 500KV, 750KV,1000KV) of cable, voltage transformer, transformer, switch, and power station etc.
-
IEC Burden Sets -
The Eastern Specialty Company
Testing and calibrating current transformers often requires standard burdens of reliable accuracy and stability, and burdens that are immune to stray fields and harmonics. These burden sets have been carefully designed to meet these requirements. They also provide the standard burdens required for the testing of current transformers for metering service, and for the testing (within the current rating provided by the sets) of current transformers for relaying applications, all as called for by IEC (International Electrotechnical Commission) Publication 185: 1987.
-
-
PCT200i -
Ponovo Power Co., Ltd.
PCT200 series CT test set (CT Analyzer) is a current transformer test equipment specially designed for current transformer characteristic test and with additional PT test functions for reference test. PCT200i owns more test items and higher technical parameters.
-
921A -
Arbiter Systems, Inc.
The Arbiter Systems®, Inc. Model 921A Combustible Gas Meter is a rugged, portable instrument that measures total combustible gases (TCG) in oil-filled transformer nitrogen gas blankets. TCG measurements have been shown to be good indicators of transformer health.
-
600V Class -
AYA-Instruments
These transformers are encased in a thermoplastic case with the core and windings encapsulated in resin. They are designed for line-to-line operation but may also be used in line-to-neutral or line-to-ground configuration at 58% of rated voltage. It is recommended that a 1.6 Amp fuse be used in the secondary to protect the transformer.
-
NeonPro
Design for finding out the total voltage of neon tubes in a circuit, help to Choose correct rating of neon transformer;- Easy to use just like a neon transformer;- With color LED indicators, clearly shows the test result;- With build-in over voltage protection circuit.
-
Applied Meters, a.s.
Single-phase static electricity meters AMS B1x-SAx are determined for direct and indirect measurement of active energy displaying value on mechanical register with stepping motor. In the case of CT (current transformer) operated meters (x/5A) it is necessary value of register to multiply by the current transformer ratio.
-
NEO TELE-TRONIX PVT. LTD
Widely used for testing transformer and switchgear, this equipment is available to clients in different capacities.
-
NEO TELE-TRONIX PVT. LTD
Widely used in electrical, power generation and engineering sector, it is used for transformer testing.
-
-
TEGAM Inc.
Ratio Standards by Tegam including ratio transformers, synchro-resolver bridge, synchro-resolver standard
-
STCS -
Altanova Group
The external module STCS allows performing automatically the following PT tests: ratio per tap; winding resistance; OLTC dynamic test. The connection to the transformer under test, to STS and to the measurement taps is performed just once; then, all transformer tests are performed without interruptions.
-
MR 8050 -
Schuetz Messtechnik GmbH
With the MR 8050 resistances highly inductive Resistance Meters windings of transformers, motors and reactors can be measured. (range 100 µΩ with 0.01µΩ resolution up to 6 kΩ). The performance of the test objects can be up to 800 MVA or even more. The magnetic loading of a transformer is performed quickly using a high loading voltage (60V). This is important for time critical measurements (cooling curves). The unloading of the transformers core is very fast, very safe, as the energy is total destroyed in the MR 8050.
-
Computer Conversions Corporation
The input is transformer isolated and accuracy applies over the operating temperature range and with +/-10% input amplitude and frequency variations. The operational amplifier outputs are not transformer isolated, and can be driven into external power amplifiers and Scott "T" transformers for 3 wire synchro outputs. A typical application of this series is in a conventional positioning servo system as a complex error processor. The use of the solid state CDX makes possible the design of servo systems that can be digitally programmed by direct computer input to the digital input of the SCDX.