Current and Potential Transformers
current and potential transformer T&M instruments.
-
Product
Current Generator
MIG1260
-
MIG1260 is a current generator with wave shape 8/20 μs. The exact waveform delivered is a function of the surge generator and the impedance to which the surge is applied. The generator can deliver up to 60kA impulse current supported by 12kV impulse voltage, making it ideal for testing big varistors with high hold-on voltage. Mechanically the MIG1260 consists of one large rack and a separate control console with high voltage output terminals protected by a glass acrylic test cabinet.
-
Product
Transformer Turns Ratio Meters
-
Vanguard Instruments Company, Inc.
The ATRT-01 S3 is Vanguard’s fourth generation, micro-processor based, single phase, automatic transformer turns-ratio tester. The ATRT-01 S3 uses the IEEE C57.12.90 measuring method to determine the transformer turns-ratio. The transformer turns-ratio is determined by precisely measuring the voltages across the unloaded transformer windings. The ATRT-01 S3’s measuring circuitry self adjusts before each measurement to ensure turns-ratio accuracy. Two selectable test voltages, 4Vac and 40Vac, offer flexibility in testing different types of transformers.
-
Product
Clamp Meters (Current)
-
Test Products International, Inc.
TPI offers a full line of digital clamp testers for electrical, commercial, HVAC/R, industrial and process control applications including the new 285 with Bluetooth connectivity to the free TPI View App.
-
Product
Current Probes
-
Current probes allow you to measure DC or AC current. Yokogawa's selection of current probes allow measurements ranges up to 500 ARMS and bandwidths up to 100MHz.
-
Product
Transformer Insulating Oil Dielectric Tester
CXYJ-501
-
Shenzhen Chuangxin Instruments Co., Ltd.
Insulating Oil Tester is designed according to of GB-86 and IEC60156 standards.
-
Product
DC current Sensors
CTH
-
The CTH sensors convert dc current to an isolated voltage output, the CTHR sensors convert ac current to a dc output signal proportional to the Arms. All popular process control voltage and current loop outputs are available. Through hole or split core options mean that connection is non-intrusive and straightforward. The available input range of the CTH sensors is any value from 5A to 6000Adc.
-
Product
Adjustable Isolating Transformers
-
PeakTech Prüf- und Messtechnik GmbH
The PeakTech 2235 is a 2 in 1 laboratory isolating transformer with integrated DC power supply, which was designed with the aspect of high safety requirements for use in research, science and repair. The device has a dual adjustable DC, AC output, which can also be used for constant voltage or current and offers high stability and performance. The output voltage or the output current can be read exactly on two separate 3-digit LED displays and the fixed output supplies a voltage of 5 V. The device is protected against damage by overload and short circuit by reliable overvoltage protection and can be placed in a 19 ”rack installed or used as a table device (“stand-alone”).
-
Product
Current Sense Resistors
-
Panasonic Industrial Devices Sales Company of America
Panasonic offers a wide variety of Thick Film Current Sense Resistors (ERJ-B1, B2, xB, xBW, xCW) in a large range of case sizes and in wide terminal types for high solder joint reliability. The ERJ Series of Current Sense Resistors offers power ratings up to 2W with low ohmic ratings ranging from 5mΩ to 10Ω. Panasonic’s Thick Film Current Sense Resistor portfolio offers a more cost effective option with high reliability. Panasonic has a wide line of case size options ranging from 0402 to 2512 in conventional terminal and 0612 to 1020 for wide terminal.
-
Product
Transformer Ratio Meters
Handheld Turns Ratio & Winding Resistance Tester TWR-H
-
TWR-H is a handheld, battery operated, fully automatic test set specially designed for turns ratio, phase shift, excitation current and winding resistance measurements of transformers. It can also perform demagnetization of these transformers. Transformer turns ratio is determined by applying AC voltage across high voltage winding, accurately measuring AC voltage across the corresponding unloaded transformer winding, and then displaying the ratio of these voltages. User can enter a transformer’s nameplate voltages, so that turns ratio deviation can be calculated. This feature eliminates any error otherwise caused by an operator’s manual calculation. TWR-H compares measured turns ratio with the nameplate ratio and prints out the % of error for each test. Transformer winding resistance is determined by injecting DC current through a winding, accurately measuring DC voltage across the winding, and then calculating resistance as the ratio of voltage and current. The device generates true DC ripple-free currents. Both the injection of the current and the discharge of energy from transformer magnetic circuit are automatically regulated.
-
Product
Transformer Winding Resistance Meters
RMO TT Series
-
The Tap Changer Analyzer & Winding Ohmmeter of the RMO-TT series is designed for winding resistance measurement of inductive objects, and for a tap changer analysis. The RMO-TT series is based on the state of the art technology, using the most advanced switch mode technology available today. The RMO-TT instruments are accurate (0,1%), powerful (up to 100 A) and still portable. The Instruments generate a true DC ripple free current with automatically regulated measurement and discharging circuit. RMO-TT instruments can perform a simple, quick and reliable transformer on-load tap changer condition assessment. This series of instruments enable measurements of a winding resistance in every tap position, current ripple values (percentage of a current drop during a tap change) and transition times during the tap changes. Problems with a connection, contacts, and selector/diverter switch operation (tap change with interruption) can be detected with these measurements.
-
Product
OEM Current Input0 to 20mA
TGPR-0800
-
A current input data logger that is supplied uncased so that it can be built into custom applications.The TGPR-0800 can be used to record the output from a number of industry standard 4-20mA sensors. Common applications include pressure and flow rate monitoring.
-
Product
Transform Imagery into Geospatial Understanding
Feature Analyst™
-
Textron Systems' Feature Analyst is tightly integrated with the Esri® ArcGIS® platform to extract feature data from imagery in order to populate geographic information systems (GIS) databases. Analysts can rapidly and accurately collect vector feature data from high-resolution satellite and aerial imagery in order to gain spatial understanding.
-
Product
High Current Probe HCF73512B400G500
1016176
-
The HCF73512B400G500 is a state-of-the-art High Current Probe designed for a wide range of applications, capable of delivering a continuous current of 12.00A. Boasting an impressive operating temperature range of -45°C to +200°C, this probe is engineered to perform reliably in various environments. Its basic contact probe design features a pitch of 5.00 mm (197 mil), ensuring precise alignment and functionality in testing and measurement applications. The HCF73512B400G500 is crafted from high-quality materials, including a beryllium copper plunger that is gold plated for optimal conductivity, and a brass barrel also finished with gold plating, enhancing both performance and durability.
-
Product
Surface Charge and Zeta Potential
-
Surface analysis is a vital method for qualifying new materials in technical and biological applications. Surface charge analysis empowers users to closely monitor the surface chemistry from small particles in the nanometer range up to large wafers. Gain insights into modifications resulting from surface treatment and surface interactions with natural environments under near-ambient conditions. Get a competitive edge in optimizing existing products and developing new ones using the Anton Paar instruments which offer zeta potential measurement for a wide range of applications.
-
Product
High Current Probe HC200D06G73NTCCF
1125165
-
The High Current Probe HC200D06G73NTCCF (item number 1125165) is designed for safe transmission of high electrical currents in test and contacting applications. HC200D06G73NTCCF focuses on current capacity and low transition losses, as required in battery testing, formation and other e-mobility applications. For HC200D06G73NTCCF, contact resistance, contact force and thermal behavior must be considered together because they influence voltage drop and temperature rise at the contact point. The intended application area for HC200D06G73NTCCF includes battery contacting. The electrical rating of HC200D06G73NTCCF combines 300 A continuous current with 0.2 mΩ typical contact resistance. For HC200D06G73NTCCF, spring force is 7000 cN at a nominal travel of 5.6 mm.
-
Product
High Current Probe HCF77311B140G150
1012027
-
The HCF77311B140G150 High Current Probe is designed for precision in power electronics applications. With a robust construction featuring beryllium copper for the plunger and gold plating for enhanced conductivity, this probe can handle continuous currents up to 30A, making it ideal for demanding electrical environments. Its operational temperature range of -45°C to +200°C ensures versatility across various settings, while the basic contact configuration allows for effective and reliable measurements in power circuitry.
-
Product
Split Core Current Transformers
-
Application:Watt Transducer, Current Transducer, KWH Meter, Demand Meter, Power Factor Meter, Current Sensing Relays, Energy Management SystemsContinuous Thermal: Rating 1.25 at 30° C, 1.0 at 55° C Standard 5-amp secondary. Others available.
-
Product
Transformer Protection
-
Schweitzer Engineering Laboratories, Inc.
Transformer protection products and systems provide complete primary and backup protection for all types of transformer faults. They are suited for use in utility-, industrial-, and commercial-scale power transformer systems.
-
Product
Current Transformers
-
Supreme Instrument Laboratories
Portable Low Tension precision grade multi ratio Current Transformers, housed in laminated wooden cabinet, wound primary with suitable terminals on highly insulated bakelite panel upto 100 Amps. For higher ranges, a centre hole is provided for passing primary conductors for desired range.
-
Product
Current
-
ACI’s comprehensive current sensor line includes transmitters, switches, and relays—and the technical support to solve the most challenging applications
-
Product
ACP Portable Electrical Current Transformer Test,CT/PT Analyzer
-
Chongqing Assen Power Equipment Co., Ltd
ACP portable Current transformer analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data. The CT PT Analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE and IEC standards.
-
Product
Transformer Test System
-
Transformer testing instrument, can be used as a stand-alone device and has the highest efficiency. Can be used in power transformers, network communication transformers, etc.
-
Product
Inductive Sensors (eddy Current)
eddyNCDT
-
Inductive sensors from Micro-Epsilon are based on the eddy current principle and designed for non-contact measurement of displacement, distance, position, oscillation and vibrations. They are particularly suitable when high precision is required in harsh industrial environments (pressure, dirt, temperature). Inductive sensors from Micro-Epsilon offer extremely precise measurements where sub-micron accuracy is required.
-
Product
High Current Probes HCF77216B100G150A
1165651
-
The HCF77216B100G150A is an advanced high current probe specifically designed for battery contacting applications, showcasing an optimized blend of precision and durability. This probe operates reliably within a temperature range of -45°C to +200°C, making it suited for various environments where high performance is crucial. The basic contact probe features a pitch of 2.54 mm (100 mil), ensuring compatibility in a wide array of electrical configurations.
-
Product
Dual Surge Current Generator
MIG0624T-K12
-
Designed for testing telecom surge protection devices according to ITU-T K12. The generator has two indepedent impulse outputs which allow testing of two and three terminal protection devices such as gas discharge tubes (GDT). The generator can be configured for two terminal devices or with the outputs in parallel to increase the current impulse for two terminal devices.
-
Product
AC and DC Current Sources
-
Programmable AC and DC current sources that provide precise, low noise, stable currents for a number of applications.
-
Product
High Current Switches
-
Marvin Test Solutions’ switch card portfolio includes matrix, multiplexer, and RF multiplexer configurations. 3U and 6U PXI switch cards feature easy to use, reliable, and integration-friendly D-sub style interface connectors – a feature unique to Marvin Test Solutions PXI switch cards. GENASYS switch cards are compatible with MTS’s family of GENASYS Switching and Switching/Digital Subsystems, featuring integrated MAC Panel SCOUT receivers.
-
Product
Voltage And Current Calibrator
-
Precision Mastech Enterprises Co.
A precision instrument designed to generate (source) and measure precise electrical signals.
-
Product
ANSI Metering Current Transformer Burden
-
The ANSI Current transformer burden is designed for loading the current transformer during accuracy Tests. The ANSI burden is designed as per ANSI burden C57.13.It can be used along with the Eltel Automatic Instrument Transformer Test Set to test CTs as per ANSI Standards.
-
Product
Low Current Probe 80A
695
-
Great tool for accurate measurement of low current. Use with your graphing meter or lab scope to view current waveforms on fuel injectors, fuel pumps, primary ignition coils and more. Also works very well with digital multimeters. Resolution of 10 milliamps is low enough for most parasitic drain testing. In addition, the clamp opening of 1/2 inch is large enough to clamp over most negative battery cables for those parasitic drain tests.