Current and Potential Transformers
current and potential transformer T&M instruments.
-
Product
Injection Transformer
J2100A
-
The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.
-
Product
Transformer Turns Ratio Meter
TTRM 302
-
SCOPE introduces state of the art precision three phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. Along with turns ratio, this light weight and reliable instrument measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single as well as three phase transformers in charged switchyard condition. The instrument has facility to automatically detect vector group of all majority configurations available. The differant AC voltage selection offers high accuracy in measurement.
-
Product
High Frequency Current Transformer
HFCT Ø 140mm
-
Techimp Clamp High Frequency Current Transformer model 140 is an inductive sensor for partial discharge measurements. It is suitable for online /off line PD tests on : large diameter cables ; grounding rod bar ; etc. A TNC termination is available to connect the Clamp HFCT 140 to the TechImp PD analyzer : PDCheck , PDBase etc. The arrow indicates the requested input current (Iin) direction to get coherent output voltage (Vout) polarity respect to ground. When the sensor is installed with the arrow directed to ground, the detected voltage signal (Vout) has the same phase of the input current (Iin).
-
Product
Linear Variable Differential Transformers (LVDTs)
-
Whilst there are several ways to measure displacement, the Linear Variable Differential Transformer (LVDT) remains a popular transducer in most industrial applications. LVDTs initially were used as a means of taking dimensional readings in laboratories. They gained popularity in a wide variety of industrial monitoring and control applications, and whilst an LVDT is used to measure displacement the technology can be employed within other transducer types.
-
Product
Ethernet Transformers
-
Pulse’s Ethernet transformers are RoHS compliant and qualified at major PHY suppliers. 100/1000/2.5G/5G/10GBASE-T Ethernet transformer modules are optimized for all major LAN transceivers. All modules provide electrical circuit isolation that meets IEEE 802.3, while maintaining signal integrity needed for the most demanding applications.
-
Product
Current Clamp Multimeters
-
PeakTech Prüf- und Messtechnik GmbH
It uses a pair of jaw which allow clamping around an electrical conductor to measure the current in a conductor without the need to make physical contact unlike a normal multimeter.
-
Product
Eddy Current Dynamometers
WT Dyno
-
Our WT series eddy current dynamometers are mainly used in the development and testing of all types of prime mover, as well as various engine assemblies. Due to their robust design, which incorporates improved control characteristics, they can be used both as steady state and as transient test stands.Their high speeds for automobile engine testing and their optimised cooling chamber, are convincing arguments that speak for themselves. All WT type dynamometers are suitable for operation in both directions of rotation.
-
Product
Current Transformer
-
OutputDC 10VLinearityAs graph aboveApplied VoltageAC 2000V, 1min (between aperture and terminals)ImpendanceDC 500V, over 100M (between aperture and terminals)Fire Retardant Level94V0Output Terminals2.54 mm pinAnti-vibration50 Hz 5G
-
Product
Ocean Current
-
Designed for long-term, high-accuracy monitoring of water quality, temperature, salinity, and water levels in oceans, coastal waters, and tidal areas.
-
Product
Precision Current Transformers
7223CT-2S
-
Guildline Instruments NEW 7223CT-2S Series of Precision AC Current Transformers provides very accurate AC current measurements at high current and for high voltages. The 7223CT-2S is part of the 7223CT Series which are Commercially Available High Precision, Low and High Voltage, AC Current Instruments Capable of Measurement Accuracy <5 part-per-million (ppm) – Accuracies No Other Manufacturer Provides!
-
Product
Current to Digital
-
Analog Devices’ breakthrough current-to-digital converter technology is backed by award winning expertise to help solve your medical, industrial, and security application needs. Our high speed, high resolution ADC modules enable improved CT scanner data acquisition, photodiode sensors and power monitoring, spectroscopy, and high channel count data acquisition systems.
-
Product
Single Gas Transformer DGA
-
Hydran composite gas Dissolved Gas Analysis (DGA) products provide essential online monitoring of transformer oil. The Hydran line is the perfect cost-effective application for small- and medium-sized transformers where customers need to know about developing fault conditions that could cause unscheduled outages.The Hydran products allow for the addition of expansion to the base unit, allowing for greater measurement accuracy
-
Product
Transformer Capacity Tester
-
Weshine Electric Manufacturing Co., Ltd
In many industries, including health care, manufacturing, electrical contracting, higher education and corrections, reliable, high-quality transformers are essential for keeping operations running efficiently. Large facilities and industrial processes require substantial amounts of power, and they need dependable transformers to convert the energy coming from the power plant into a form they can use for their equipment and building utilities.
-
Product
Transformer Turn Ratio Instrument
ART-3D
-
The ART-3D is high precision instrument designed to measure ratios, magnetization currents, phase-shifting in power transformers, distribution transformers, potential and current transformers, in conformity to IEEE C57.12.90 and CEI/IEC 60076.
-
Product
Transformer Turn Ratio Meter
-
A specialized, highly accurate diagnostic instrument used to measure the ratio of primary to secondary winding turns in transformers.
-
Product
Current Mirrors
-
Analog Devices current mirrors are precision, high dynamic range, wide variable supply parts used for optical power monitoring, voltage biasing with current monitoring, and voltage-to-current conversion. Our current mirrors can monitor current down to as little as 3 nA and as much as 3 mA, with a linearity of 1% or better. The current dynamic range is 120 dB or 6 decades of current range, while the overcurrent protection feature in our devices forces the input pin to ground to avoid part damage. Over temperature (–40°C to +85°C) and process, the dynamic range only suffers 10 dB at the lower end of the range.
-
Product
Three-Phase Transformer Winding Resistance Meters
TWA Advanced Series
-
TWA Advanced series is the latest DV Power solution for three-phase transformer winding resistance measurement and tap changer analysis. They are capable of testing six transformer windings with a single cable connection, as well as three-phase automatic transformer demagnetization. It has the option of the automated test mode, where the instrument operates the tap changer without operator input (minimizing the risk of human error) and records winding resistance results based on pre-selected stabilization criteria.The unique DVtest method of tap changer analysis enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, together with the measurement of tap changer motor current which detects motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or simultaneously on three phases. It can also be performed together with the winding resistance test in all tap positions.A unique advantage of TWA Advanced instruments is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer connected in a YN configuration. This can significantly speed up the testing– for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.TWA500 is equipped with a large 10.1” graphical touch-screen display, while TWA400 has a 7” graphical touch-screen display. Besides making the interface much more user-friendly compared to older winding ohmmeters, it also enables certain test options that were previously available only with DV-Win software. The most important among them are DVtest, tap changer motor current measurement, “Heat Run” test, test templates, and automatic test mode.
-
Product
High Current Connectors
-
C.C.P. Contact Probes Co., LTD.
60% lower extraction force, 80% higher current than other common connectors. The numbers speak for themselves.
-
Product
Transformer Degaussing Analyzer
KRI6691
-
The KRI6691 transformer degaussing analyzer injects current into the test winding by applying ±90V voltage, and collects the terminal voltage and winding current to draw the hysteresis characteristic curve. Linear quantitative analysis of transformer remanence can be performed, and rapid demagnetization can be achieved by tracking the hysteresis curve.
-
Product
Current sensors
-
Assistance systems support the driver and assure safety in the latest generation of automobiles. Infotainment systems entertain passengers during car journeys and provide navigation. Seats are no longer adjusted manually, and doors are opened and closed with electric motors. The ever increasing electrification is driven by many other factors besides convenience and safety though.
-
Product
Transformer Winding Resistance Meters
RMO TW Series
-
The RMO-TW instrument can perform a simple, fast and reliable verification of a transformer on-load tap changer. This instrument allows measurements of a winding resistance at each tapping position of an on-load tap changer without discharging between tests. Problems with OLTC switching, such as interruption, can be detected with these measurements. The results are displayed on a backlit LCD screen.
-
Product
Current Booster
PHPC01
-
PHPC01 current booster is an accessory which can work together with protection relay test kit to test transformer protection relay testing. It is specifically designed to supply high compliance voltage even at small current range.
-
Product
Current Sources
-
Innovar Current Sources are the standard in the circuit breaker industry. Our Current Sources supply regulated current from 1 amp to 100,000 amps with incredible accuracy, along with providing a full set of features that is unmatched by any other Current Source in the market.
-
Product
Current Sense Magnetics
-
Current sense magnetics are used as a low loss method for sensing AC current in a circuit and also provide electrical and safety isolation between the source of the current and the measurement circuit. The key parameters for a current sense transformer are the rms current rating (to ensure it does not overheat in the application) and the safety and voltage isolation (to ensure it conforms to the end-application requirements).
-
Product
Transformer Preamplifier
SR554
-
Stanford Research Systems, Inc.
The SR554 is a low-noise, transformer-coupled preamplifier optimized for source impedances between 0.05 Ω and 1 kΩ. With an input noise of only 0.1 nV/√Hz, the SR554 can be used in a wide range of low-noise applications.
-
Product
Single-point Current Meter
-
The SEAGUARD® is the core module used in small and medium sized underwater observatories. Whether used as a multipurpose instrument, or as a hub for strings in the water column, the SeaGuard manages connected sensors and the real-time communication of data and meta-data to shore. In autonomous configurations, long battery life is achieved with aggressive power routines keeping the full system at the lowest power levels possible.
-
Product
Transformer Regulation
-
Transformer Parallel Control System is designed to monitor & control the tap changers of up to four (4) transformers connected on a common bus & operating in a MASTER FOLLOWER control configuration.
-
Product
NI-9208, 500 S/s, ±20 mA, 16-Channel C Series Current Input Module
780968-01
Current Input Module
500 S/s, ±20 mA, 16-Channel C Series Current Input Module - The NI‑9208 is designed with industrial systems in mind. It includes a high-resolution mode with 50/60 Hz rejection to remove low frequency noise. It has high-channel density to reduce the number of modules needed, which leaves slots open for other measurement types or for reducing the overall per channel cost of the system. The NI‑9208 uses a standard D‑SUB connection for use with cables and connector blocks.
-
Product
Isolation Transformers 230V
-
PeakTech Prüf- und Messtechnik GmbH
Due to the high safety requirements in service workshops, schools and industry, an isolating transformer is an absolute prerequisite for carrying out professional repair work. Galvanic isolation between primary and secondary voltage during measurements and repairs on open devices guarantees a high safety standard for the user. Of course, galvanic isolation from the mains voltage also offers other advantages in electronics development, audio technology and many other areas.





























