Filter Results:
Products
Manufacturers
Applications
-
product
Probes
71 Series
American Probe & Technologies, Inc.
10 mil (0.010") shank sizesAvailable in straight and bent shapes
-
product
Active Probes
To ensure that as much information as possible is available at your fingertips, the IOM6 Hub can be used to increase the number of FNet ports on the iC5700 BlueBox by 4. Now you can combine our CAN/LIN data capture, analog and digital capture and control, and debug and trace all from one central hardware tool via our Active Probes
-
product
Test Probes
Safety right angle insulated alligator test probe, safety right angle insulated alligator test probe with insulated jaws, test probe, minitest probe, micro test probe.
-
product
Microscopic Probes
M12PP
CAPRES M12PP Microscopic Twelve-Point Probes are specialized versions of the CAPRES Micro Multi-Point Probes. By using a dedicated 12-by-4 multiplexer, a total of 495 different pin-configurations can be obtained, each with different probe pitch. This is utilized in e.g. the CIPTech, where 8 or more combinations are used to obtain a “depth profiling” of the measured structures.
-
product
Logic Probes
Logic probes are used to analyze the logic states (high/true: logic 1 or low/false: logic 0) of digital signals. To verify and debug today’s high-speed, low-voltage digital signals, you need logic probes that can accurately acquire signals from a wide variety of electronic designs, while protecting signal fidelity. Tektronix logic analyzer probes contain a variety of connectivity options that are engineered to ensure that signal acquisition is a true reflection of your design's performance. Compare and learn more about Tektronix logic analyzer probe solutions below.
-
product
Near Field Probes
Used for accompanying measurements of high-frequency, electric and magnetic RF fields on assemblies and devices.
-
product
Medical Temperature Probes
types include: skin medical temperature probes, general purpose medical probes, esophagael/stethoscope medical temperature probes and foley catheter medical temperature probes.
-
product
TSP100 Switch Probes
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
product
MEP General Purpose Probes
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 25Test Center (mm): 0.635Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 750Overall Length (mm): 19.05Rec. Mounting Hole Size (mil): 20.5Rec. Mounting Hole Size (mm): 0.52Rec. Mounting Hole Remark: 20.5 to 21.5 mil / 0.52 to 0.55 mmRecommended Drill Size: #75 or 0.52 mm
-
product
UV-measurement probes
For example, some UV probes must work reliably at high temperatures, in rain or under water. Meander MDR-10 (available in our shop). EMC-tested switching power supply with protective conductor connection, eg Meanwell MDR-10.
-
product
BTP-1 Bead Probes
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Custom Probes
At Eddyfi, we strive to meet the most rigorous requirements. Our expertise, engineers, and manufacturing capabilities enable us to take almost any set of custom inspection requirements — dimensions, diameters, geometries, number of coil rows, topologies — and turn them into practical and high-performance solutions for you.
-
product
High Impedance Active Probes
7
Designed as a companion probe to Models 12C and 18C for driving integrated circuit lines so the Model 12C and 18C can be used to measure the response of adjacent nodes. The Model 7 consists of a flexible 6 foot, 50 ohm coaxial cable accurately terminated to 50 ohms in order to avoid undesirable reflections. A special miniature connector receives replacement coaxial probe tips that provide a shielded environment to within 3 mm of the fine tungsten probe point, thus minimizing capacitive coupling to other parts of the circuit. The replaceable coaxial probe tips are offered in various point sizes and can also be bent to any shape in order to accommodate a variety of probing geometries.
-
product
Raman Probes
As with Raman spectrometers, a Raman probe is used to measure the inelastic scattering of light from a sample. Raman scattering is produced when the energy levels of photons are shifted up or down as a result of excitation by a monochromatic source (usually a laser). The change in vibrational frequency is used to determine the composition of a target substance.
-
product
Test Fingers & Probes
Test Fingers and Probes are used in most standards to check accessibility to moving parts or hazardous live parts. They comes in many forms, such as test fingers, test rods, test balls etc.
-
product
Small Aperture Fiber-Optic Probes
Small-aperture Fiber-optic Probes are best for testing closely-spaced LEDs. With an aperture of 1mm, and a diameter of 1.2mm/0.050 inches, they can test LEDs spaced as close as 0.050 inches on center. Small-aperture Fiber-optic Probes are available with straight or right-angle stainless-steel tips as shown below. This allows for precise customization to your mechanical constraints.
-
product
CCA-006 Battery Probes
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 78Full Travel (mm): 1.98Recommended Travel (mil): 40Recommended Travel (mm): 1.02Overall Length (mil): 669Overall Length (mm): 16.99
-
product
C-S General Purpose Probes
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 45Full Travel (mm): 1.14Recommended Travel (mil): 30Recommended Travel (mm): 0.76Overall Length (mil): 395Overall Length (mm): 10.03Rec. Mounting Hole Size (mil): 46.5Rec. Mounting Hole Size (mm): 1.18Recommended Drill Size: 56
-
product
H.V. Probes
PD-20
Standard Electric Works Co., Ltd
● Measures both AC and DC voltages with digital multitester.● Are typically used to measure high voltages in TV sets, power supplies and instruments in laboratories.● Lightweight and rugged.● 2 available contact tips: round needle tip for normal use and a special flat spring-type for CRT anode.
-
product
Near Field Probes
Anteral has extensive background in the design of Near Field Probes (open ended waveguides probes). Our Near Field Probes are currently being used in several laboratories around the world including the ESA's anechoic chamber. Anteral designs Near Field Probes from 10 GHz to 750 GHz covering the sectors requirements. Moreover, our Near Field Probes have a sharped design minimize reflections.
-
product
Test Probes and Pins
Spring Loaded Test Probes for Circuit Board Testing, "Pogo Pins" Test Electronics sources and stockes a large variety of Test Probes and Spring Loaded Test Pins. Let our applications engineers help you find the correct pin for your test fixture application.
-
product
Smart Probes
A wide selection of rugged smart probes for your sensing needs. From non-contact IR sensors to a full range of sensor types including Temperature, Humidity, Process, RTD, Thermocouple, pulse, and mor...
-
product
Conical Laser Power Probes
Conical Head Power Probes are used to measure high power density CO2 laser beams which may damage the standard flat surfaced Power Probes. The conical absorbing cavity exhibits a high heat dissipation.
-
product
Low Voltage Single Ended Probes
A low voltage single-ended probe is typically used for measuring high-speed, ground referenced signals up to 12 V. These low voltage probes are the best choice for making measurements on high impedance, high frequency circuit elements which require minimal probe loading. Users should select probes with a low input capacitance specification (~1 pF) to minimize the probe’s loading effect on the circuit. A probe with lower input capacitance will offer higher input impedance at higher frequencies.





























